Document
EMC - CB Certificate
Brand
Device
Audio
File
on-time-200id.pdf
Date

JBL ON TIME 200ID EMC - CB Certificate ▷ View online

 
 
<12014165 001> 
 
 
Page 12 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
11 
FAULT CONDITIONS 
11.1 
No shock hazard under fault condition 
No electric shock during fault operation. 
For details refer to appended table 11.2. 
11.2 
Heating under fault condition 
See below. 
 
No hazard from softening solder 
No solder point became soft. 
 
No flaming more than 10s 
No flame. 
 
Soldered terminations not used as protective 
mechanism 
 
11.2.1 
Measurement of temperature rises 
(see appended table) 
11.2.2 
Temperature rise of accessible parts 
(see appended table) 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(see appended table) 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
No points on the PCB exceed the limit. 
N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm² 
 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 
N/A 
 
Class I protective earthing maintained 
Class II appliance. 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
(see appended table) 
11.2.5 
Temperature rise of windings 
(see appended table) 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts" 
 
N/A 
 
 
 
 
12 
MECHANICAL STRENGTH 
N/A 
12.1.1 
Bump test where mass >7 kg 
Direct plug-in equipment. 
N/A 
12.1.2 
Vibration test (portable, metal, musical amps) 
 
N/A 
12.1.3 
Impact hammer test  
 
N/A 
 
Steel ball test (for non-ventilated solid areas) 
 
N/A 
 
 
<12014165 001> 
 
 
Page 13 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
12.1.4 
Drop test for portable apparatus where mass = 7 
kg 
 
N/A 
12.1.5 
Thermoplastic enclosures stress relief test 
 
N/A 
12.2 
Fixing of knobs, push buttons, keys and levers 
No such parts provided. 
N/A 
12.3 
Remote controls with hazardous live parts 
No remote control provided. 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawers provided. 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
No antenna coaxial sockets provided. 
N/A 
12.6 
Telescoping or rod antennas construction 
Not such a construction. 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
13.1 
Clearances in accordance with 13.3 
Clearance measured according to annex 
E. Pollution degree 2 was considered. 
 
Creepage distances in accordance with 13.4 
Creepage distances measured according 
to annex E. Pollution degree 2 was 
considered. 
13.2 
Determination of operating voltage 
For obtaining the operating voltages the 
EUT was connected to a 240 V TN 
power system.  
The highest operating voltages are 
measured as follows: 
 
pins 
Vpk  Vrms 
T1 
  1-A 
   288    151 
 
  2-A 
   292    155 
 
  4-A 
   334    155 
               5-A        440      228 
               1-B        398      181 
               2-B        202      126 
               4-B        210      126 
               5-B        496      272 
13.3 
Clearances 
See below. 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
(see appended table) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
 
N/A 
13.3.4 
Measurement of transient voltages 
 
N/A 
 
 
<12014165 001> 
 
 
Page 14 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
13.4 
Creepage distances 
 
 
Creepage distances greater than table 11 minima 
(see appended table) 
13.5 
Printed boards 
No coated PCB used. 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
No such parts provided. 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
Not such a construction. 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
The sources of optocoupler is in 
compliance with the requirements of sub-
clause 8.8, for details refer to appended 
table 14. 
 
 
 
 
14 
COMPONENTS 
14.1 
Resistors 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors provided. 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 
N/A 
 
Resistors separately approved  ............................... :   
N/A 
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
(see appended table) 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  ... :  The capacitor CY1 connected between 
the hazardous live and secondary circuits 
is subclass Y1 capacitor approved 
according to IEC 60384-14+A1. 
 
 
<12014165 001> 
 
 
Page 15 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  ... :  The capacitor CX1 conductively 
connected between the lines of the mains 
supply is subclass X2 capacitor approved 
according to IEC 60384-14+A1. 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ...................... : 
No such capacitors provided. 
N/A 
14.2.5     a)  Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ....................................................................... : 
All sources of the X capacitors are tested 
as category B or better according to sub-
clause 4.38 of IEC 60384-14. 
b) 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ........................................ : 
Electrolytic capacitors provided with 
metal can. 
 
Shielded by a barrier per Table 21 .......................... :   
N/A 
14.3 
Inductors and windings 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 
N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ............................... : 
The transformer is marked with type and 
manufacturer information (as code), 
provided as label on the cores. 
 
Transformers and inductors separately approved  . :  Tested with appliance. 
N/A 
14.3.2 
General 
 
14.3.3 
Constructional requirements (complete appended 
tables or include manufacturers constructional 
insulation descriptions) 
See below. 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table 13.3 and 13.4) 
14.3.3.2 
Transformers meet the constructional 
requirements 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Reinforced or double insulation between 
primary winding/parts and secondary 
winding/parts. Details see appended 
table 13.3 and 13.4. 
 
Coil formers and partition walls = 0,4 mm 
  Partition wall of T1 with 0,5mm 
thickness minimum. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Not a class I transformer design. 
N/A 
Page of 91