JBL ON TIME 200ID EMC - CB Certificate ▷ View online
<12014165 001>
Page 12 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
11
FAULT CONDITIONS
P
11.1
No shock hazard under fault condition
No electric shock during fault operation.
For details refer to appended table 11.2.
For details refer to appended table 11.2.
P
11.2
Heating under fault condition
See below.
P
No hazard from softening solder
No solder point became soft.
P
No flaming more than 10s
No flame.
P
Soldered terminations not used as protective
mechanism
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
No points on the PCB exceed the limit.
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
Class II appliance.
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table)
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts"
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts"
N/A
12
MECHANICAL STRENGTH
N/A
12.1.1
Bump test where mass >7 kg
Direct plug-in equipment.
N/A
12.1.2
Vibration test (portable, metal, musical amps)
N/A
12.1.3
Impact hammer test
N/A
Steel ball test (for non-ventilated solid areas)
N/A
<12014165 001>
Page 13 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
12.1.4
Drop test for portable apparatus where mass = 7
kg
kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
No such parts provided.
N/A
12.3
Remote controls with hazardous live parts
No remote control provided.
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawers provided.
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial sockets provided.
N/A
12.6
Telescoping or rod antennas construction
Not such a construction.
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
P
13.1
Clearances in accordance with 13.3
Clearance measured according to annex
E. Pollution degree 2 was considered.
E. Pollution degree 2 was considered.
P
Creepage distances in accordance with 13.4
Creepage distances measured according
to annex E. Pollution degree 2 was
considered.
to annex E. Pollution degree 2 was
considered.
P
13.2
Determination of operating voltage
For obtaining the operating voltages the
EUT was connected to a 240 V TN
power system.
EUT was connected to a 240 V TN
power system.
The highest operating voltages are
measured as follows:
measured as follows:
pins
Vpk Vrms
T1
1-A
288 151
2-A
292 155
4-A
334 155
5-A 440 228
1-B 398 181
2-B 202 126
4-B 210 126
5-B 496 272
1-B 398 181
2-B 202 126
4-B 210 126
5-B 496 272
P
13.3
Clearances
See below.
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
(see appended table)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4
Measurement of transient voltages
N/A
<12014165 001>
Page 14 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
13.4
Creepage distances
P
Creepage distances greater than table 11 minima
(see appended table)
P
13.5
Printed boards
No coated PCB used.
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
No such parts provided.
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
Not such a construction.
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
The sources of optocoupler is in
compliance with the requirements of sub-
clause 8.8, for details refer to appended
table 14.
compliance with the requirements of sub-
clause 8.8, for details refer to appended
table 14.
P
14
COMPONENTS
P
14.1
Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors provided.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ............................... :
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved
(see appended table)
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ... : The capacitor CY1 connected between
the hazardous live and secondary circuits
is subclass Y1 capacitor approved
according to IEC 60384-14+A1.
is subclass Y1 capacitor approved
according to IEC 60384-14+A1.
P
<12014165 001>
Page 15 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ... : The capacitor CX1 conductively
connected between the lines of the mains
supply is subclass X2 capacitor approved
according to IEC 60384-14+A1.
supply is subclass X2 capacitor approved
according to IEC 60384-14+A1.
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors provided.
N/A
14.2.5 a) Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
All sources of the X capacitors are tested
as category B or better according to sub-
clause 4.38 of IEC 60384-14.
as category B or better according to sub-
clause 4.38 of IEC 60384-14.
P
b)
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Electrolytic capacitors provided with
metal can.
metal can.
P
Shielded by a barrier per Table 21 .......................... :
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
The transformer is marked with type and
manufacturer information (as code),
provided as label on the cores.
manufacturer information (as code),
provided as label on the cores.
P
Transformers and inductors separately approved . : Tested with appliance.
N/A
14.3.2
General
P
14.3.3
Constructional requirements (complete appended
tables or include manufacturers constructional
insulation descriptions)
tables or include manufacturers constructional
insulation descriptions)
See below.
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table 13.3 and 13.4)
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Reinforced or double insulation between
primary winding/parts and secondary
winding/parts. Details see appended
table 13.3 and 13.4.
primary winding/parts and secondary
winding/parts. Details see appended
table 13.3 and 13.4.
P
Coil formers and partition walls = 0,4 mm
Partition wall of T1 with 0,5mm
thickness minimum.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Not a class I transformer design.
N/A