JBL ON TIME 200ID EMC - CB Certificate ▷ View online
<12014165 001>
Page 4 of 73
IEC60065E
ASTABEAB
Model list :
INPUT
OUTPUT
MODEL
V, A
Vdc
A
W max.
T1 sec. winding
3,0-6,0
0,5-3,0
18,0
Ø0,55mm×3P×6Ts
6,1-8,9
0,5-3,0
24,0
Ø0,55mm×2P×9Ts
9,0-12,0
0,5-2,5
24,0
Ø0,80mmx13Ts
12,1-16,0
0,5-1,8
24,0
Ø0,60mmx17Ts
S024Ezxy
AC100-240V
50/60Hz,
0,6Amax.
16,1-24,0
0,5-1,4
24,0
Ø0,35mm×2Px26Ts
Note:
‘z’ can be ‘V’, ‘B’, ‘U’, ‘C’ and ‘M’. ‘V’ means Euro-plug used, ‘B’ means BS plug used, ‘U’ means American plug
used, ‘C’ means Chinese plug used, ‘M’ means integrate appliance coupler used (plug can be replaceable,
including Euro-plug, BS plug, American plug and Chinese plug.).
‘x’ is 3 digit number which represents the output voltage in volt dividing by 10, from 3,0V to 24,0V by step of 0,1V, for
example, 030 represents the output voltage is 3,0V, 240 represents the output voltage is 24,0V.
example, 030 represents the output voltage is 3,0V, 240 represents the output voltage is 24,0V.
‘y’ is 4 digit number which represents the output current in ampere dividing by 100, from 0,5A to 3,0A by step of
0,01A, for example, 0300 represents the output current is 3,0A, 0050 represents the output current is 0,5A.
0,01A, for example, 0300 represents the output current is 3,0A, 0050 represents the output current is 0,5A.
<12014165 001>
Page 5 of 73
IEC60065E
ASTABEAB
Copy of marking plate:
There are representative labels; the others are identical to this one except the model name and output ratings
Date code was moulded on the external enclosure:
Date code was moulded on the external enclosure:
<12014165 001>
Page 6 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
3
GENERAL REQUIREMENTS
P
Safety class of the apparatus ................................. : Class II
P
4
GENERAL CONDITIONS OF TESTS
P
4.1.4
Ventilation instructions require the use of the test
box
box
No.
P
5
MARKING
P
Comprehensible and easily discernible
All markings are printed on outer
enclosure of the appliance.
enclosure of the appliance.
P
Permanent durability against water and petroleum
spirit
spirit
After rubbing test by water and petroleum
spirit, the markings are still easily
discernible, indelible and legible.
spirit, the markings are still easily
discernible, indelible and legible.
P
5.1
a), b)
Identification, maker, model .................................... :
Trademark “
” and model no. are
marked on the outer enclosure.
P
c)
Class II symbol if applicable
Double square symbol.
P
d), e)
Rated supply voltage and symbol ........................... : 100-240V~
P
f)
Frequency if safety dependant
50/60Hz
P
g), h), i)
Rated current or power consumption ..................... : 0,6A max
P
5.2
a)
Earth terminal
Class II appliance.
N/A
b)
Hazardous live terminals
No such terminals provided.
N/A
c)
Supply output terminals (other than mains)
The nominal output voltage and current
are marked on the name label.
are marked on the name label.
P
5.3
Use of triangle with exclamation mark
Symbol provided at appropriate section of
the circuit diagram.
the circuit diagram.
P
5.4
Instructions for use
English,
Instruction in other language will be
provided when national approvals.
Instruction in other language will be
provided when national approvals.
P
5.4.1
a)
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
or splashing. Warning concerning objects filled with
liquid, etc.
See user manual.
P
b)
Hazardous live terminals, instructions for wiring
No such terminals provided.
N/A
c)
Instructions for replacing lithium battery
No batteries provided.
N/A
<12014165 001>
Page 7 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
Instructions for modem if fitted
No modern provided.
N/A
d)
Class I earth connection warning
Class II appliance.
N/A
e)
Instructions for multimedia system connection
Not multimedia system.
N/A
f)
Special stability warning for fixed installation
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
A mains plug that is part of direct plug-in
equipment was used as disconnect
device.
equipment was used as disconnect
device.
P
Instructions for permanently connected equipment Not permanently connected equipment.
N/A
6
HAZARDOUS RADIATION
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation or laser inside the
EUT.
EUT.
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ..... : See above.
N/A
Emission limits under fault conditions .................... : See above.
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values,
any single protective device defeated except those
of Cl. 7.1 a) and b)
any single protective device defeated except those
of Cl. 7.1 a) and b)
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
(see appended table)
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION AGAINST
ELECTRIC SHOCK
ELECTRIC SHOCK
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Enamel coating of winding and the
surface material electrolytic capacitors
are not considered as safety isolation.
surface material electrolytic capacitors
are not considered as safety isolation.
P
Click on the first or last page to see other ON TIME 200ID service manuals if exist.