JBL ON TIME 200ID EMC - CB Certificate ▷ View online

 
 
<12014165 001> 
 
 
Page 4 of 73 
 
 
IEC60065E 
 
ASTABEAB 
 
Model list : 
 
INPUT 
OUTPUT 
MODEL 
V, A 
Vdc 
A  
W max. 
T1 sec. winding 
3,0-6,0 
0,5-3,0 
18,0 
Ø0,55mm×3P×6Ts 
6,1-8,9 
0,5-3,0 
24,0 
Ø0,55mm×2P×9Ts 
9,0-12,0 
0,5-2,5 
24,0 
Ø0,80mmx13Ts 
12,1-16,0 
0,5-1,8 
24,0 
Ø0,60mmx17Ts 
S024Ezxy 
AC100-240V 
50/60Hz,  
0,6Amax. 
16,1-24,0 
0,5-1,4 
24,0 
Ø0,35mm×2Px26Ts 
 
Note: 
‘z’ can be ‘V’, ‘B’, ‘U’, ‘C’ and ‘M’. ‘V’ means Euro-plug used, ‘B’ means BS plug used, ‘U’ means American plug 
used, ‘C’ means Chinese plug used, ‘M’ means integrate appliance coupler used (plug can be replaceable, 
including Euro-plug, BS plug, American plug and Chinese plug.). 
‘x’ is 3 digit number which represents the output voltage in volt dividing by 10, from 3,0V to 24,0V by step of 0,1V, for 
example, 030 represents the output voltage is 3,0V, 240 represents the output voltage is 24,0V. 
‘y’  is 4 digit number which represents the output current in ampere dividing by 100, from  0,5A  to  3,0A  by  step  of 
0,01A,  for example, 0300 represents the output current is 3,0A, 0050 represents the output current is 0,5A. 
 
 
 
 
<12014165 001> 
 
 
Page 5 of 73 
 
 
IEC60065E 
 
ASTABEAB 
Copy of marking plate: 
 
 
 
         
 
 
 
 
 
 
 
There are representative labels; the others are identical to this one except the model name and output ratings 
 
 
Date code was moulded on the external enclosure: 
 
 
 
 
 
 
<12014165 001> 
 
 
Page 6 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
GENERAL REQUIREMENTS 
 
Safety class of the apparatus  ................................. :  Class II 
 
 
 
GENERAL CONDITIONS OF TESTS 
4.1.4 
Ventilation instructions require the use of the test 
box 
No. 
 
 
 
MARKING 
 
Comprehensible and easily discernible 
All markings are printed on outer 
enclosure of the appliance. 
 
Permanent durability against water and petroleum 
spirit 
After rubbing test by water and petroleum 
spirit, the markings are still easily 
discernible, indelible and legible. 
5.1  
a), b) 
Identification, maker, model .................................... : 
Trademark “
” and model no. are 
marked on the outer enclosure. 
c) 
Class II symbol if applicable 
Double square symbol. 
d), e) 
Rated supply voltage and symbol ........................... :  100-240V~ 
f) 
Frequency if safety dependant 
50/60Hz 
g), h), i) 
Rated current or power consumption  ..................... :  0,6A max 
5.2  
a) 
Earth terminal 
Class II appliance. 
N/A 
b) 
Hazardous live terminals 
No such terminals provided. 
N/A 
c) 
Supply output terminals (other than mains) 
The nominal output voltage and current 
are marked on the name label. 
5.3 
Use of triangle with exclamation mark 
Symbol provided at appropriate section of 
the circuit diagram. 
5.4 
Instructions for use 
English,  
Instruction in other language will be 
provided when national approvals. 
5.4.1   
a) 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled with 
liquid, etc. 
See user manual. 
b) 
Hazardous live terminals, instructions for wiring 
No such terminals provided. 
N/A 
c) 
Instructions for replacing lithium battery 
No batteries provided. 
N/A 
 
 
<12014165 001> 
 
 
Page 7 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
 
Instructions for modem if fitted 
No modern provided. 
N/A 
d) 
Class I earth connection warning 
Class II appliance. 
N/A 
e) 
Instructions for multimedia system connection 
Not multimedia system. 
N/A 
f) 
Special stability warning for fixed installation 
 
N/A 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
A mains plug that is part of direct plug-in 
equipment was used as disconnect 
device. 
 
Instructions for permanently connected equipment  Not permanently connected equipment. 
N/A 
 
 
 
 
HAZARDOUS RADIATION 
N/A 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation or laser inside the 
EUT. 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 ..... :  See above. 
N/A 
 
Emission limits under fault conditions  .................... :  See above. 
N/A 
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
7.1 
Temperature rises not exceeding specified values, 
any single protective device defeated except those 
of Cl. 7.1 a) and b) 
(see appended table) 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table) 
7.1.4 
Temperature rise of windings 
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
(see appended table) 
 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION AGAINST 
ELECTRIC SHOCK 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Enamel coating of winding and the 
surface material electrolytic capacitors 
are not considered as safety isolation. 