<12014165 001> 
 
 
Page 16 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
14.3.4.3 
Separating transformers with at least basic 
insulation 
Not such a transformer design. 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
See sub-clause 14.3.4.1 above. 
 
Coil formers and partition walls = 0,4 mm 
 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Not a class I transformer design. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
N/A 
14.4 
High voltage components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No component operating at voltage 
exceeding 4kV. 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 
Protective devices 
 
Protective devices used within their ratings 
See sub-clause 14.5.2.1. 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
(see appended table 13.3 and 13.4) 
14.5.1.1 
a) Thermal cut-outs separately approved 
No thermal cut-outs provided. 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
No thermal link provided. 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
No such components provided. 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuse link source complies with IEC 
60127-2. For source details refer to 
appended table 14. 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... :  Fuse marked on PCB adjacent to 
component as: F1 T3,15AL250V. 
 
 
<12014165 001> 
 
 
Page 17 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
14.5.2.3 
Not possible to connect fuses in parallel  ................ :  No such holders provided that would 
allow parallel connection. 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool .......... : 
No fuse link can be replaced without 
use a tool. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such components provided. 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
Fusing resistor is used, detail see page 3 
and marked on PCB adjacent to 
components as: F1 2,2Ω/1W. 
The test under fault condition is carried 
out three times. 
14.6 
Switches 
No switches provided. 
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
V-0 compliance with annex G, G.1.1 
and 
Peak inrush rating of switch 
Measured/calculated inrush…………………………: 
 
N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 
14.6.4 and V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1 
 
N/A 
 
Switch controlling = 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking 
action independent of speed of actuation 
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d), l) and m) not 
attaining excessive temperatures in use 
 
N/A 
 
 
<12014165 001> 
 
 
Page 18 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
 
N/A 
 
Socket outlet current marking correct 
 
N/A 
14.7 
Safety interlocks 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
No safety interlocks provided. 
N/A 
14.8 
Voltage setting devices 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
Full range voltage design, no voltage 
setting device provided. 
N/A 
14.9 
Motors 
N/A 
14.9.1 
Endurance test on motors 
No motors provided. 
N/A 
 
Motor start test 
 
N/A 
 
Dielectric strength test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 
N/A 
14.10 
Batteries 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
No batteries provided. 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 
 N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 
N/A 
14.10.4 
Battery mould stress relief 
 
N/A 
14.10.5 
Battery drop test 
 
N/A 
14.11 
Optocouplers 
 
Optocouplers comply with Cl. 8 
Certified sources of optocoupler used. 
(see appended table) 
 
 
<12014165 001> 
 
 
Page 19 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
 
See sub-clause 8.8. 
14.12 
Surge suppression varistors 
 
Comply with IEC 61051-2 
Certified sources of varistors are used. 
(see appended table) 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
Not connected to accessible parts/output 
circuits. 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
Certified source with suitable 
characteristics used. 
 
 
 
 
15 
TERMINALS 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
A mains plug that is part of direct plug-in 
equipment provided. Details see table 
14. 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
No risk of insertion in mains socket-outlets 
Output connector. 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II appliance. 
N/A 
 
Class I supply equipment with non-hazardous live 
output voltage: output circuit not connected to earth 
 
N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 
N/A 
 
Earthing connection of parts removable by hand. 
 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 Ω at 25 A  ................... :   
N/A 