JBL ON TIME 200ID EMC - CB Certificate ▷ View online
<12014165 001>
Page 16 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
14.3.4.3
Separating transformers with at least basic
insulation
insulation
Not such a transformer design.
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
See sub-clause 14.3.4.1 above.
P
Coil formers and partition walls = 0,4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Not a class I transformer design.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
No component operating at voltage
exceeding 4kV.
exceeding 4kV.
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
P
Protective devices used within their ratings
See sub-clause 14.5.2.1.
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
(see appended table 13.3 and 13.4)
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs provided.
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No thermal link provided.
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No such components provided.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuse link source complies with IEC
60127-2. For source details refer to
appended table 14.
60127-2. For source details refer to
appended table 14.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : Fuse marked on PCB adjacent to
component as: F1 T3,15AL250V.
P
<12014165 001>
Page 17 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
14.5.2.3
Not possible to connect fuses in parallel ................ : No such holders provided that would
allow parallel connection.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .......... :
replacing fuse-links without the use of a tool .......... :
No fuse link can be replaced without
use a tool.
use a tool.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such components provided.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
Fusing resistor is used, detail see page 3
and marked on PCB adjacent to
components as: F1 2,2Ω/1W.
and marked on PCB adjacent to
components as: F1 2,2Ω/1W.
The test under fault condition is carried
out three times.
out three times.
P
14.6
Switches
No switches provided.
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated inrush…………………………:
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
N/A
<12014165 001>
Page 18 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950
No safety interlocks provided.
N/A
14.8
Voltage setting devices
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
Full range voltage design, no voltage
setting device provided.
setting device provided.
N/A
14.9
Motors
N/A
14.9.1
Endurance test on motors
No motors provided.
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N/A
14.10
Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
No batteries provided.
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
P
Optocouplers comply with Cl. 8
Certified sources of optocoupler used.
(see appended table)
P
<12014165 001>
Page 19 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
See sub-clause 8.8.
P
14.12
Surge suppression varistors
P
Comply with IEC 61051-2
Certified sources of varistors are used.
(see appended table)
P
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
Not connected to accessible parts/output
circuits.
circuits.
P
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
Certified source with suitable
characteristics used.
characteristics used.
P
15
TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
A mains plug that is part of direct plug-in
equipment provided. Details see table
14.
equipment provided. Details see table
14.
P
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
Output connector.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
P
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
P
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II appliance.
N/A
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to earth
output voltage: output circuit not connected to earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Earthing connection of parts removable by hand.
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1 Ω at 25 A ................... :
N/A