National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
Canadian National Difference according to CB Bulletin No. 109A, December 2005
12.3A.1
For television sets and similar apparatus using a cathode ray
tube larger than 160 mm diagonally, the top, sides, front, and
rear of the enclosure, including the safety screen where
provided, shall be capable of withstanding a single impact of 7
J in accordance with Clause 12.3A.2 without developing any
opening larger than 130 mm in the enclosure of the cathode
ray tube, unless the minor dimension of 2 any opening is not
more than 7 mm.
tube larger than 160 mm diagonally, the top, sides, front, and
rear of the enclosure, including the safety screen where
provided, shall be capable of withstanding a single impact of 7
J in accordance with Clause 12.3A.2 without developing any
opening larger than 130 mm in the enclosure of the cathode
ray tube, unless the minor dimension of 2 any opening is not
more than 7 mm.
When applied to a safety screen, the impact shall not result in
damage to its mounting to the extent that it is mechanically
unsuitable for reuse, nor shall tempered glass, if used, be
cracked.
damage to its mounting to the extent that it is mechanically
unsuitable for reuse, nor shall tempered glass, if used, be
cracked.
When applied to the face of a directly viewed cathode ray
tube, the impact shall not cause any opening in the face of the
tube.
tube, the impact shall not cause any opening in the face of the
tube.
Scaling and cracking of the glass shall be permissible. A
cathode ray tube that has been shown to comply with
CAN/CSA – C22.2 No. 228 or CAN/CSA – E 61965 shall be
considered acceptable with no further tests.
cathode ray tube that has been shown to comply with
CAN/CSA – C22.2 No. 228 or CAN/CSA – E 61965 shall be
considered acceptable with no further tests.
No television
N/A
12.3A.2
The impact specified in clause 12.3A.1 shall be caused by
following a solid, smooth, steel sphere 51mm in diameter
and weighing approximately 0.5kg to strike the enclosure
with the specified impact in a direction perpendicular to the
enclosure surface. If deemed necessary, the enclosure shall
be tested with the proper cathode ray tube mounted.
following a solid, smooth, steel sphere 51mm in diameter
and weighing approximately 0.5kg to strike the enclosure
with the specified impact in a direction perpendicular to the
enclosure surface. If deemed necessary, the enclosure shall
be tested with the proper cathode ray tube mounted.
Considered.
P
13.3
Clearances
N/A
13.3.1
General
Add the following after the third paragraph
Clearances between a loudspeaker voice coil and adjacent
conductive parts shall be disregarded.
conductive parts shall be disregarded.
No such component.
N/A
14.2
Capacitors and RC - units
P
14.2.1
Add the following paragraph
As an alternative, an isolating capacitor complying with
applicable requirements of CSA C22.2 No. 1 shall be
acceptable for bridging basic or supplementary insulation.
applicable requirements of CSA C22.2 No. 1 shall be
acceptable for bridging basic or supplementary insulation.
Considered.
P
14.2.2
Add the following paragraph
As an alternative, a cross-line capacitor complying with
applicable requirements of CSA C22.2 No. 1 shall be
acceptable.
applicable requirements of CSA C22.2 No. 1 shall be
acceptable.
Considered.
P
<12014165 001>
Page 45 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
Canadian National Difference according to CB Bulletin No. 109A, December 2005
14.5.1
14.5.1.2
Thermal releases
Add the following paragraph
As an alternative, a thermal link complying with CSA C22.2
No. 209 shall be acceptable.
No. 209 shall be acceptable.
No thermal link provided.
N/A
14.5.2
Fuse – links and fuse holders
P
14.5.2.1
Add the following paragraph
As an alternative, a fuse-link complying with CSA C22.2 No.
284.14 shall be acceptable.
284.14 shall be acceptable.
Considered.
P
14.5.2.4
Add the following paragraph
As an alternative, a fuseholder assembly complying with
CSA Standard C22.2 No. 39 shall be acceptable.
CSA Standard C22.2 No. 39 shall be acceptable.
No fuse holder provided.
N/A
14.6
14.6.1 to
14.6.5
Switches
Add the following paragraph
As an alternative, a TV-rated switch complying with CSA
C22.2 No. 1, Clause 9 shall be acceptable.
C22.2 No. 1, Clause 9 shall be acceptable.
No switch provided.
N/A
14.11
Optocouplers
Add the following paragraph
As an alternative, an optocoupler complying with CSA C22.2
No. 1 shall be acceptable.
No. 1 shall be acceptable.
Considered.
P
14.12
Surge suppression varistors
Add the following paragraph
Add the following paragraph
As an alternative, an varistor complying with CSA C22.2 No.
1 shall be acceptable.
1 shall be acceptable.
Considered.
P
14.12A
Gas discharge tubes
Add the following clause
Gas discharge tubes complying with following tests may be
connected to bridge basic or reinforced insulation. Ten
samples of gas discharge tubes isolating the ac supply from
exposed parts shall be subjected to the varistor pulse tests of
Clause 14.12.
connected to bridge basic or reinforced insulation. Ten
samples of gas discharge tubes isolating the ac supply from
exposed parts shall be subjected to the varistor pulse tests of
Clause 14.12.
Following the pulses, the device shall be allowed to return to
room temperature. The dielectric breakdown voltage of the
gas tube shall not decrease by more than 50%, and the gas
discharge tube shall comply with the dielectric strength test of
Clause 10.3, with the test voltage reduced to twice the mains
voltage.
room temperature. The dielectric breakdown voltage of the
gas tube shall not decrease by more than 50%, and the gas
discharge tube shall comply with the dielectric strength test of
Clause 10.3, with the test voltage reduced to twice the mains
voltage.
No gas discharge tubes
provided.
provided.
N/A
<12014165 001>
Page 46 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
Canadian National Difference according to CB Bulletin No. 109A, December 2005
15.1
Plugs and sockets
P
15.1.1
Add the following paragraph
A receptacle provided for general purpose mains output shall
comply with the requirements of CSA Standard C22.2 No. 42
(dimensional requirements are also specified in IEC 60906-2).
The attachment plug cap shall be polarized type when the
apparatus is provided with a manually operated, MAINS
connected single pole switch for apparatus on-off operation, a
socket screw shell lampholder, or a 15 or 20 ampere socket
outlet.
comply with the requirements of CSA Standard C22.2 No. 42
(dimensional requirements are also specified in IEC 60906-2).
The attachment plug cap shall be polarized type when the
apparatus is provided with a manually operated, MAINS
connected single pole switch for apparatus on-off operation, a
socket screw shell lampholder, or a 15 or 20 ampere socket
outlet.
Direct plug-in appliance.
N/A
15.1.2
Add the following paragraph
Banana plugs shall be acceptable.
No such plug
N/A
15.1.3
Add the following title
Adapter output connectors
Replace the first paragraph with the following
Terminals and connectors used in output circuits of supply
apparatus, whose output voltage is not a standard nominal
mains voltage according to IEC 60038 (1), IEC 60320, IEC
60884, IEC 60906 (parts 1, 2, and 3), and CSA C22.2 No. 42.
apparatus, whose output voltage is not a standard nominal
mains voltage according to IEC 60038 (1), IEC 60320, IEC
60884, IEC 60906 (parts 1, 2, and 3), and CSA C22.2 No. 42.
No such components.
N/A
15.2
Provisions for protective earthing
Replace the first paragraph with the following
Earthing connections shall comply with the test requirements
of CSA C22.2 No. 0.4.
of CSA C22.2 No. 0.4.
Class II equipment.
N/A
15.3
Terminals for external flexible cords and for permanent
connection to the mains supply
connection to the mains supply
N/A
15.3.1A
Add the following clause
Equipment intended for permanent connection to the mains
shall have provisions for connection to the wiring system in
accordance with the Canadian Electrical Code, Part I.
shall have provisions for connection to the wiring system in
accordance with the Canadian Electrical Code, Part I.
The terminal parts and all other provisions for permanent
connection to fixed wiring shall comply CSA Standard
CAN/CSA-C22.2 No. 0.
connection to fixed wiring shall comply CSA Standard
CAN/CSA-C22.2 No. 0.
Direct plug-in appliance.
N/A
<12014165 001>
Page 47 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
Canadian National Difference according to CB Bulletin No. 109A, December 2005
15.4
15.4.2
Devices forming a part of the mains plug
Add the following paragraphs
Mains plugs of non-permanently installed equipment shall
comply with
comply with
a) CSA C22.2 No. 21 for moulded-on type attachment plugs;
and
and
b) CSA C22.2 No. 42 for disassembly type attachment plugs
(dimensional requirements are also specified in IEC 60906-2).
(dimensional requirements are also specified in IEC 60906-2).
Class II equipment provided with a general purpose mains
outlet, or lampholder, shall be provided with a polarized-type
plug. If the plug is a polarized type, single pole switches or
over current protectors shall not be connected in the identified
conductor.
outlet, or lampholder, shall be provided with a polarized-type
plug. If the plug is a polarized type, single pole switches or
over current protectors shall not be connected in the identified
conductor.
Shall be evaluated during
national approval.
national approval.
N/A
16
16.1
External flexible cords
Replace this clause with the following
Flexible cord used for mains supply shall comply with the
requirements of CSA C22.2 No. 49. The cord type shall be in
accordance with Table 4 of CSA C22.2 No. 1.
requirements of CSA C22.2 No. 49. The cord type shall be in
accordance with Table 4 of CSA C22.2 No. 1.
The attachment plug shall be rated not less than 125% of the
apparatus rated current.
apparatus rated current.
Cord sets shall comply with the requirements of CSA C22.2
No. 21.
No. 21.
Non-detachable flexible cables and cords of Class I
apparatus shall be provided with a green/yellow core
connected to the protective earthing terminal of the apparatus
and, if a plug is provided, to the protective earthing contact of
the plug.
apparatus shall be provided with a green/yellow core
connected to the protective earthing terminal of the apparatus
and, if a plug is provided, to the protective earthing contact of
the plug.
Compliance is checked by inspection.
Note: The colour for cores of flexible mains cords is contained
in IEC 60173 (4).
in IEC 60173 (4).
Direct plug-in appliance.
N/A
17
Electrical connections and mechanical fixings
N/A
17.9A
Adhesive securement and conductive coatings
Add the following clause
N/A