Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-44
HDR-FX1000/FX1000E_ADJ
28. White Defect & HS Defect Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect white defective pixels of CMOS image sensor.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value
Data of page: 6 address: D3 is “00”
Note 1:
Perform “STD GAIN Adjustment” before this adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Preparation for adjustment:
1) Before starting the adjustment, perform the aging to raise the
temperature so that the set becomes ready for adjustment.
Aging temperature judge mode:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
09
3
F
5D
1D
Press PAUSE (Write) button.
(9F)
4
During the aging, the screen
will be as follows.
(Fig. 6-1-13)
5
When the aging completed,
execute the subsequent steps
to exit the aging temperature
judge mode.
6
F
5D
00
Press PAUSE (Write) button.
(9F)
7
0
10
00
8
0
01
00
Fig.6-1-12
CMOS temperature checking method:
Order Page Address Data
Procedure
1
0
FF
06
2
7
78
Check the data is “00”.
3
7
79
Check the data is “1D” to
“2A”. (Note 4)
4
0
FF
00
Note 4:
If the data is other than “1D” to “2A”, perform the aging.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
D0
81
5
6
01
21
Press PAUSE (Write) button.
6
6
02
Check the data changes to
“01”.
7
6
01
00
Press PAUSE (Write) button.
8
6
D0
06
9
6
01
21
Press PAUSE (Write) button.
10
6
02
Check the data changes to
“01”.
11
6
D3
Check the data is “00”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
Aging completed
(Exceeding the set 
temperature)
Excessive aging
(Exceeding appropriate 
adjustment temperature)
During aging
(Below the set temperature)
6-45
HDR-FX1000/FX1000E_ADJ
29. White Defect Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect white defective pixels (FD white point) of CMOS image
sensor.
Subject
Not required
Note 1:
Perform “White Defect & HS Defect Adjustment” be-
fore this adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
D0
0C
5
6
01
21
Press PAUSE (Write) button.
6
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
30. White Defect Check 
RadarW
RadarW
RadarW
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value 1
Data of page: 6 address: D1 is “00”
Specified value 2
Data of page: 6, address: D2 is “00”
to “06”
Note 1:
Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
D0
04
5
6
01
21
Press PAUSE (Write) button.
6
6
02
Check the data changes to
“01”.
7
6
D1
Check the data is “00”.
8
6
D2
Check the data is “00” to
“06”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
6-46
HDR-FX1000/FX1000E_ADJ
31. Black Defect Adjustment 1 (Bch) 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect black defective pixels of CMOS image sensor.
Subject
Clear chart (All white) (Note 1)
Note 1:
Shoot the clear chart with the zoom TELE end.
Note 2:
 Perform “White Defect Check” before this adjustment.
Note 3:
 Check that the data of page: 0, address: 10 is “00”.
Note 4:
 Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) ZOOM switch (Lens block) ....................................... SERVO
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
99
Check the data is “00”.
5
6
2C
01
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
10
10
6
01
79
Press PAUSE (Write) button.
11
Wait for 4 seconds.
12
6
01
00
Press PAUSE (Write) button.
13
Check that the entire screen
is white.
14
6
D0
01
15
6
D1
01
16
6
01
21
Press PAUSE (Write) button.
17
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
01
79
Press PAUSE (Write) button.
7
Wait for 4 seconds.
8
6
01
00
Press PAUSE (Write) button.
9
6
2C
00
10
0
01
00
32. Black Defect Adjustment 2 (Gch) 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect black defective pixels of CMOS image sensor.
Subject
Clear chart (All white) (Note 1)
Note 1:
Shoot the clear chart with the zoom TELE end.
Note 2:
 Perform “White Defect Check” before this adjustment.
Note 3:
 Check that the data of page: 0, address: 10 is “00”.
Note 4:
 Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) ZOOM switch (Lens block) ....................................... SERVO
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
99
Check the data is “00”.
5
6
2C
01
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
10
10
6
01
79
Press PAUSE (Write) button
11
Wait for 4 seconds.
12
6
01
00
Press PAUSE (Write) button.
13
Check that the entire screen
is white.
14
6
D0
01
15
6
D1
02
16
6
01
21
Press PAUSE (Write) button.
17
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
01
79
Press PAUSE (Write) button.
7
Wait for 4 seconds.
8
6
01
00
Press PAUSE (Write) button.
9
6
2C
00
10
0
01
00
6-47
HDR-FX1000/FX1000E_ADJ
33. Black Defect Adjustment 3 (Rch) 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect black defective pixels of CMOS image sensor.
Subject
Clear chart (All white) (Note 1)
Note 1:
Shoot the clear chart with the zoom TELE end.
Note 2:
 Perform “White Defect Check” before this adjustment.
Note 3:
 Check that the data of page: 0, address: 10 is “00”.
Note 4:
 Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) ZOOM switch (Lens block) ....................................... SERVO
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
99
Check the data is “00”.
5
6
2C
01
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
10
10
6
01
79
Press PAUSE (Write) button.
11
Wait for 4 seconds.
12
6
01
00
Press PAUSE (Write) button.
13
Check that the entire screen
is white.
14
6
D0
01
15
6
D1
04
16
6
01
21
Press PAUSE (Write) button.
17
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
01
79
Press PAUSE (Write) button.
7
Wait for 4 seconds.
8
6
01
00
Press PAUSE (Write) button.
9
6
2C
00
10
0
01
00
34. Angular Velocity Sensor Sensitivity Adjustment
• Perform the angular velocity sensor sensitivity adjustment only
when replacing the angular velocity sensor or lens block. When
the microprocessor, circuit, etc. malfunctions, do not perform
this adjustment but check operations only.
• Record the sensitivity label of the angular velocity sensor (re-
pair part), including to which side of the board it was attached
to, etc. If it has been attached incorrectly, the image will move
up and down or to the left and right during steady shot opera-
tion. Be sure to take note of this.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03RC – 04
Type B
ENC03RD
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing,
readjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.