Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-60
HDR-FX1000/FX1000E_ADJ
5.
Processing After Adjustments
Set the data after “CAP FG duty adjustment”, “Switching position
adjustment”, “SD error rate check”.
Data change method:
Order Page Address Data
Procedure
1
0
01
01
2
3
C4
00
3
3
C5
00
4
0
01
00
6-61
HDR-FX1000/FX1000E_ADJ
1-2. S VIDEO OUT Y Level Adjustment (VC-543 board)
Mode
VCR mode
Signal
No signal
Measurement Point
Y signal terminal of S VIDEO plug
of A/V R connector (75 
Ω termi-
nated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25 (NTSC)
7E (PAL)
Specified value
A = 1000 
± 14 mVp-p
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
25
Change the data and set the Y
signal level (A) to the
specified value.
3
C
25
Press PAUSE (Write) button.
4
C
7E
Set a value obtained by
subtracting 3 from the
forementioned data, and
press PAUSE (Write) button.
5
Perform “Processing after
Complete Adjustment”.
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
7E
Change the data and set the Y
signal level (A) to the
specified value.
3
C
7E
Press PAUSE (Write) button.
4
C
25
Set a value obtained by
adding 3 to the
forementioned data, and
press PAUSE (Write) button.
5
Perform “Processing after
Complete Adjustment”.
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the speci-
fied values of “Origin Oscillation Check” of “1-3. CAMERA SYS-
TEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. S VIDEO OUT Y level adjustment
2. S VIDEO OUT chroma level adjustment
3. VIDEO OUT level check
4. COMPONENT OUT Y level adjustment
5. COMPONENT OUT Pr level adjustment
6. COMPONENT OUT Pb level adjustment
1.
S VIDEO, VIDEO OUT Adjustment
1-1. Preparations
Perform the following data setting before the “S VIDEO,
VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
Set the unit to VCR mode.
2
0
01
01
3
7
83
03
4
3
71
01
Press PAUSE (Write) button.
5
0
10
01
6
C
0F
10
Press PAUSE (Write) button.
(1C)
7
8
00
01
Press PAUSE (Write) button.
(18)
8
8
01
60
Press PAUSE (Write) button.
(18)
9
8
06
55
Press PAUSE (Write) button.
(18)
10
8
04
C0
Press PAUSE (Write) button.
(18)
11
Wait for 3.5 seconds.
12
0
10
00
13
0
FF
3E
14
B
00
02
15
C
85
Check the data is “55”.
16
0
FF
00
Fig. 6-3-3
H
A
6-62
HDR-FX1000/FX1000E_ADJ
1-3. S VIDEO OUT Chroma Level Adjustment
(VC-543 board)
Mode
VCR mode
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
plug of A/V R connector (75 
terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V R connector
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27 (NTSC)
7F, 80 (PAL)
  Specified value
Cr level: A = 714 
± 14 mVp-p(NTSC)
A = 700 
± 14 mVp-p(PAL)
Cb level: B = 714 
± 14 mVp-p(NTSC)
B = 700 
± 14 mVp-p(PAL)
Burst level: C = 286 
± 6 mVp-p(NTSC)
   C = 300 
± 6 mVp-p(PAL)
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
26
Change the data and set the
Cr signal level (A) to the
specified value.
3
C
26
Press PAUSE (Write) button.
4
C
7F
Set a value obtained by
subtracting 5 from the
forementioned data, and
press PAUSE (Write) button.
5
C
27
Change the data and set the
Cb signal level (B) to the
specified value.
6
C
27
Press PAUSE (Write) button.
7
C
80
Set a value obtained by
subtracting 3 from the
forementioned data, and
press PAUSE (Write) button.
8
Check the burst signal (C) to
the specified value.
9
Perform “Processing after
Complete Adjustment”.
Fig. 6-3-4
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
7F
Change the data and set the
Cr signal level (A) to the
specified value.
3
C
7F
Press PAUSE (Write) button.
4
C
26
Set a value obtained by
adding 5 to the
forementioned data, and
press PAUSE (Write) button.
5
C
80
Change the data and set the
Cb signal level (B) to the
specified value.
6
C
80
Press PAUSE (Write) button.
7
C
27
Set a value obtained by
adding 3 to the
forementioned data, and
press PAUSE (Write) button.
8
Check the burst signal (C) to
the specified value.
9
Perform “Processing after
Complete Adjustment”.
H
A
0.28 
µ
sec (NTSC)
B
0.28 
µ
sec (NTSC)
0.23 
µ
sec (PAL)
0.23 
µ
sec (PAL)
C
6-63
HDR-FX1000/FX1000E_ADJ
1-5. Processing after Complete Adjustment
Perform the setting through the procedure mentioned below when
you finish the “S VIDEO, VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
0
10
01
2
C
0F
00
Press PAUSE (Write) button.
(1C)
3
8
04
80
Press PAUSE (Write) button.
(18)
4
8
00
00
Press PAUSE (Write) button.
(18)
5
8
01
00
Press PAUSE (Write) button.
(18)
6
8
06
00
Press PAUSE (Write) button.
(18)
7
0
10
00
8
3
70
10
Press PAUSE (Write) button.
9
3
70
Check the data changes to
“11”.
10
7
83
00
11
0
01
00
1-4. VIDEO OUT Level Check (VC-543 board)
Mode
VCR mode
Signal
No signal
Measurement Point
VIDEO OUT plug of A/V R
connector (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Specified value
Sync level: A = 286 
± 18 mVp-p(NTSC)
A = 300 
± 18 mVp-p(PAL)
Burst level: B = 286 
± 18 mVp-p(NTSC)
B = 300 
± 18 mVp-p(PAL)
Checking method:
Order Page Address Data
Procedure
1
Peform “Preparations”
2
Check the sync signal level
(A) to the specified value.
3
Check the burst signal level
(B) to the specified value.
4
Perform “Processing after
Complete Adjustment”.
Fig. 6-3-5
H
B
A
Page of 81
Display