Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online
6-60
HDR-FX1000/FX1000E_ADJ
5.
Processing After Adjustments
Set the data after “CAP FG duty adjustment”, “Switching position
adjustment”, “SD error rate check”.
adjustment”, “SD error rate check”.
Data change method:
Order Page Address Data
Procedure
1
0
01
01
2
3
C4
00
3
3
C5
00
4
0
01
00
6-61
HDR-FX1000/FX1000E_ADJ
1-2. S VIDEO OUT Y Level Adjustment (VC-543 board)
Mode
VCR mode
Signal
No signal
Measurement Point
Y signal terminal of S VIDEO plug
of A/V R connector (75
of A/V R connector (75
Ω termi-
nated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25 (NTSC)
7E (PAL)
7E (PAL)
Specified value
A = 1000
± 14 mVp-p
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
25
Change the data and set the Y
signal level (A) to the
specified value.
signal level (A) to the
specified value.
3
C
25
Press PAUSE (Write) button.
4
C
7E
Set a value obtained by
subtracting 3 from the
forementioned data, and
press PAUSE (Write) button.
subtracting 3 from the
forementioned data, and
press PAUSE (Write) button.
5
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
7E
Change the data and set the Y
signal level (A) to the
specified value.
signal level (A) to the
specified value.
3
C
7E
Press PAUSE (Write) button.
4
C
25
Set a value obtained by
adding 3 to the
forementioned data, and
press PAUSE (Write) button.
adding 3 to the
forementioned data, and
press PAUSE (Write) button.
5
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the speci-
fied values of “Origin Oscillation Check” of “1-3. CAMERA SYS-
TEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
fied values of “Origin Oscillation Check” of “1-3. CAMERA SYS-
TEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. S VIDEO OUT Y level adjustment
2. S VIDEO OUT chroma level adjustment
3. VIDEO OUT level check
4. COMPONENT OUT Y level adjustment
5. COMPONENT OUT Pr level adjustment
6. COMPONENT OUT Pb level adjustment
1. S VIDEO OUT Y level adjustment
2. S VIDEO OUT chroma level adjustment
3. VIDEO OUT level check
4. COMPONENT OUT Y level adjustment
5. COMPONENT OUT Pr level adjustment
6. COMPONENT OUT Pb level adjustment
1.
S VIDEO, VIDEO OUT Adjustment
1-1. Preparations
Perform the following data setting before the “S VIDEO,
VIDEO OUT Adjustment”.
VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
Set the unit to VCR mode.
2
0
01
01
3
7
83
03
4
3
71
01
Press PAUSE (Write) button.
5
0
10
01
6
C
0F
10
Press PAUSE (Write) button.
(1C)
7
8
00
01
Press PAUSE (Write) button.
(18)
8
8
01
60
Press PAUSE (Write) button.
(18)
9
8
06
55
Press PAUSE (Write) button.
(18)
10
8
04
C0
Press PAUSE (Write) button.
(18)
11
Wait for 3.5 seconds.
12
0
10
00
13
0
FF
3E
14
B
00
02
15
C
85
Check the data is “55”.
16
0
FF
00
Fig. 6-3-3
H
A
6-62
HDR-FX1000/FX1000E_ADJ
1-3. S VIDEO OUT Chroma Level Adjustment
(VC-543 board)
Mode
VCR mode
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
plug of A/V R connector (75
plug of A/V R connector (75
Ω
terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V R connector
(75
External trigger: Y signal terminal of
S VIDEO plug of A/V R connector
(75
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27 (NTSC)
7F, 80 (PAL)
7F, 80 (PAL)
Specified value
Cr level: A = 714
± 14 mVp-p(NTSC)
A = 700
± 14 mVp-p(PAL)
Cb level: B = 714
± 14 mVp-p(NTSC)
B = 700
± 14 mVp-p(PAL)
Burst level: C = 286
± 6 mVp-p(NTSC)
C = 300
± 6 mVp-p(PAL)
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
26
Change the data and set the
Cr signal level (A) to the
specified value.
Cr signal level (A) to the
specified value.
3
C
26
Press PAUSE (Write) button.
4
C
7F
Set a value obtained by
subtracting 5 from the
forementioned data, and
press PAUSE (Write) button.
subtracting 5 from the
forementioned data, and
press PAUSE (Write) button.
5
C
27
Change the data and set the
Cb signal level (B) to the
specified value.
Cb signal level (B) to the
specified value.
6
C
27
Press PAUSE (Write) button.
7
C
80
Set a value obtained by
subtracting 3 from the
forementioned data, and
press PAUSE (Write) button.
subtracting 3 from the
forementioned data, and
press PAUSE (Write) button.
8
Check the burst signal (C) to
the specified value.
the specified value.
9
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
Fig. 6-3-4
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
7F
Change the data and set the
Cr signal level (A) to the
specified value.
Cr signal level (A) to the
specified value.
3
C
7F
Press PAUSE (Write) button.
4
C
26
Set a value obtained by
adding 5 to the
forementioned data, and
press PAUSE (Write) button.
adding 5 to the
forementioned data, and
press PAUSE (Write) button.
5
C
80
Change the data and set the
Cb signal level (B) to the
specified value.
Cb signal level (B) to the
specified value.
6
C
80
Press PAUSE (Write) button.
7
C
27
Set a value obtained by
adding 3 to the
forementioned data, and
press PAUSE (Write) button.
adding 3 to the
forementioned data, and
press PAUSE (Write) button.
8
Check the burst signal (C) to
the specified value.
the specified value.
9
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
H
A
0.28
µ
sec (NTSC)
B
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
0.23
µ
sec (PAL)
C
6-63
HDR-FX1000/FX1000E_ADJ
1-5. Processing after Complete Adjustment
Perform the setting through the procedure mentioned below when
you finish the “S VIDEO, VIDEO OUT Adjustment”.
you finish the “S VIDEO, VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
0
10
01
2
C
0F
00
Press PAUSE (Write) button.
(1C)
3
8
04
80
Press PAUSE (Write) button.
(18)
4
8
00
00
Press PAUSE (Write) button.
(18)
5
8
01
00
Press PAUSE (Write) button.
(18)
6
8
06
00
Press PAUSE (Write) button.
(18)
7
0
10
00
8
3
70
10
Press PAUSE (Write) button.
9
3
70
Check the data changes to
“11”.
“11”.
10
7
83
00
11
0
01
00
1-4. VIDEO OUT Level Check (VC-543 board)
Mode
VCR mode
Signal
No signal
Measurement Point
VIDEO OUT plug of A/V R
connector (75
connector (75
Ω terminated)
Measuring Instrument
Oscilloscope
Specified value
Sync level: A = 286
± 18 mVp-p(NTSC)
A = 300
± 18 mVp-p(PAL)
Burst level: B = 286
± 18 mVp-p(NTSC)
B = 300
± 18 mVp-p(PAL)
Checking method:
Order Page Address Data
Procedure
1
Peform “Preparations”
2
Check the sync signal level
(A) to the specified value.
(A) to the specified value.
3
Check the burst signal level
(B) to the specified value.
(B) to the specified value.
4
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
Fig. 6-3-5
H
B
A
Click on the first or last page to see other HDR-FX1000 / HDR-FX1000E (serv.man3) service manuals if exist.