Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-76
HDR-FX1000/FX1000E_ADJ
10. Switch Check (4)
Page 6
Address 6A
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method 1:
1) Select page: 6, address: 69, and set data: 01.
2) Select page: 6, address: 6A.
3) By discriminating the display data, the pressed key can be discriminated.
4) Select page: 6, address: 69, and set data: 00
Address
6A
(BODY AD)
(VC-543)
(IC4201 
N20
)
00
00 to 0C
1B
0D to 27
36
32 to 3A
53
4F to 58
77
73 to 7B
A0
8B to B7
HANDLE ZOOM
OFF
(GP-025)
(S7801)
CF
B8 to E6
HANDLE ZOOM
FIX
(GP-025)
(S7801)
FF
E7 to FF
HANDLE ZOOM
VAR
(GP-025)
(S7801)
Data
11. LED Check
Page 7
Address 01, 02 and 04
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method:
Order Page Address Data
Procedure
1
Set the unit to CAMERA
mode.
2
7
01
90
3
7
02
FF
4
7
04
01
5
7
00
01
Press PAUSE (Write) button.
6
7
02
Check the data changes to
“01”.
7
Check that the following
LED are lit.
• Front recording lamp
• Rear recording lamp
• MS access lamp
• Charge lamp
8
7
01
90
9
7
02
FF
10
7
04
00
11
7
00
01
Press PAUSE (Write) button.
12
7
02
Check the data changes to
“01”.
13
7
00
00
14
7
01
00
6-77
HDR-FX1000/FX1000E_ADJ
Address
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
Function
Power supplying
Hour (H)
time
Hour (M)
Hour (L)
(BCD code)
Minute
Drum rotation
Hour (H)
counted time
Hour (M)
Hour (L)
(BCD code)
Minute
Tape run time
Hour (H)
Hour (M)
Hour (L)
(BCD code)
Minute
Remarks
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
12. Record of Use Check (1)
Page 7
Address A4 to AF
Note 1:
This data will not be erased (reset) when the lithium 3 V
power supply (PI-029 board BT7001) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: A4 to
AF.
Initializing method:
Order Page Address Data
Procedure
1
7
A4
00
Press PAUSE (Write) button.
2
7
A5
00
Press PAUSE (Write) button.
3
7
A6
00
Press PAUSE (Write) button.
4
7
A7
00
Press PAUSE (Write) button.
5
7
A8
00
Press PAUSE (Write) button.
6
7
A9
00
Press PAUSE (Write) button.
7
7
AA
00
Press PAUSE (Write) button.
8
7
AB
00
Press PAUSE (Write) button.
9
7
AC
00
Press PAUSE (Write) button.
10
7
AD
00
Press PAUSE (Write) button.
11
7
AE
00
Press PAUSE (Write) button.
12
7
AF
00
Press PAUSE (Write) button.
6-78
HDR-FX1000/FX1000E_ADJ
13. Record of Use Check (2)
Page 7
Address 90 to 95
Note 1:
This data will not be erased (reset) when the lithium 3 V
power supply (PI-029 board BT7001) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: 90 to
95.
Initializing method:
Order Page Address Data
Procedure
1
7
90
00
Press PAUSE (Write) button.
2
7
91
00
Press PAUSE (Write) button.
3
7
92
00
Press PAUSE (Write) button.
4
7
93
00
Press PAUSE (Write) button.
5
7
94
00
Press PAUSE (Write) button.
6
7
95
00
Press PAUSE (Write) button.
Address
90
91
92
93
94
95
Function
Eject count with tape
Count (H)
Count (M)
(BCD code)
Count (L)
Eject count without
Count (H)
 tape
Count (M)
(BCD code)
Count (L)
Remarks
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
14. Record of Use Check (3)
Page 7
Address C8 to CD
Note 1:
 This data will not be erased (reset) when the lithium 3 V
power supply (PI-029 board BT7001) is removed.
Note 2:
Check that the data of page: 0, address 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: C8 to
CD.
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
6-79E
HDR-FX1000/FX1000E_ADJ
Address
B0
B1
B2
B4
B5
B6
B8
B9
BA
BC
BD
BE
C0
C1
C2
C4
C5
C6
Self-diagnosis code
“Repaired by” code (Occurred 1st time)   *1
“Block function” code (Occurred 1st time)
“Detailed” code (Occurred 1st time)
“Repaired by” code (Occurred 2nd time)   *1
“Block function” code (Occurred 2nd time)
“Detailed” code (Occurred 2nd time)
“Repaired by” code (Occurred 3rd time)   *1
“Block function” code (Occurred 3rd time)
“Detailed” code (Occurred 3rd time)
“Repaired by” code (Occurred 4th time)   *1
“Block function” code (Occurred 4th time)
“Detailed” code (Occurred 4th time)
“Repaired by” code (Occurred 5th time)   *1
“Block function” code (Occurred 5th time)
“Detailed” code (Occurred 5th time)
“Repaired by” code (Occurred the last time)   *1
“Block function” code (Occurred the last time)
“Detailed” code (Occurred the last time)
15. Record of Self-diagnosis Check
Page 7
Address B0 to C6
Note 1:
 This data will not be erased (reset) when the lithium 3 V
power supply (PI-029 board BT7001) is removed.
Note 2:
Check that the data of page: 0, address 10 is “00”.
*1 : “01” 
t “C”, “03” t “E”
Using method:
1) The past self-diagnosis codes are displayed at page: 7, ad-
dress: BC to C6. Refer to “1-5. SELF-DIAGNOSIS FUNC-
TION” for detail of the self-diagnosis code.
Initializing method:
Order Page Address Data
Procedure
1
7
01
C0
2
7
00
01
Press PAUSE button.
3
7
B0 to C6
Check that the data is “00”.
4
7
00
00
5
7
01
00
Page of 81
Display