DOWNLOAD Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ↓ Size: 1.02 MB | Pages: 81 in PDF or view online for FREE

Model
HDR-FX1000 HDR-FX1000E (serv.man3)
Pages
81
Size
1.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-52
HDR-FX1000/FX1000E_ADJ
CN1004 of VC-543 board
Pin No.
Signal Name
Pin No.
Signal Name
1
XSYS_RST
11
EEP_SI_S
2
XCS_MC_FLASH
12
EEP_SI_C
3
XCS_MC_FLASH_C 13
GND
4
MD2
14
GND
5
MD2_C
15
REG_GND
6
D_2.8V
16
FRRV
7
EEP_SCK_S
17
SWP
8
EEP_SCK_C
18
REG_GND
9
EEP_SO_S
19
RF_MON
10
EEP_SO_C
20
REG_GND
2.
Procedure after operations
1) Connect the adjustment remote commander to the LANC jack.
Set the HOLD switch to ON. (Set the slide switch to SER-
VICE).
2) Select page: 3, address: 26, set data: 00, and press the PAUSE
(Write) button.
3) Select page: 3, address: 33, and set data: 00.
Fig. 6-2-1
CH1
Entrance side
Exit side
Check this section
(Normal waveform)
CH2
(Trigger)
3.3msec
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
6-2. MECHANISM  SECTION  ADJUSTMENTS
On the mechanism section adjustment
For details of mechanism section adjustments, checks, and replace-
ment of mechanism parts, refer to the separate volume “DV ME-
CHANICAL ADJUSTMENT MANUAL IX  N Mechanism  ”.
Note:
Before performing the adjustments, check the data of page:
0, address: 10 is “00”. If not, set data: 00 to this address.
2-1.
HOW  TO  ENTER  RECORD  MODE
WITHOUT  CASSETTE
1) Connect the adjustment remote commander to the LANC jack.
2) Set the HOLD switch to ON. (Set the slide switch to SER-
VICE).
3) Close the cassette compartment without the cassette.
4) Select page: 3, address: 01, set data: 0C, and press the PAUSE
(Write) button of the adjustment remote commander.
(The mechanism enters the record mode automatically.)
Note:
The function buttons become inoperable.
5) To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE (Write) button of the adjustment re-
mote commander.  (Whenever you want to quit the record
mode, be sure to quit following this procedure.)
2-2.
HOW  TO  ENTER  PLAYBACK  MODE
WITHOUT  CASSETTE
1) Connect the adjustment remote commander 
(Ref. No. J-1, J-
2)
  to the LANC jack.
2) Set the HOLD switch to ON. (Set the slide switch to SER-
VICE).
3) Close the cassette compartment without the cassette.
4) Select page: 3, address: 01, set data: 0B, and press the PAUSE
(Write) button of the adjustment remote commander.
(The mechanism enters the playback mode automatically.)
Note:
The function buttons become inoperable.
5) To quit the playback mode, select page: 3, address: 01, set
data: 00, and press the PAUSE (Write) button of the adjust-
ment remote commander.  (Whenever you want to quit the play-
back mode, be sure to quit following this procedure.)
2-3.
TAPE  PATH  ADJUSTMENT
1.
Preparation for Adjustment
1) Clean the tape running side (tape guide, drum, capstan shaft,
pinch roller, etc.).
2) Connect the adjustment remote commander to the LANC jack.
3) Set the HOLD switch to ON. (Set the slide switch to SER-
VICE).
4) Connect an oscilloscope to VC-543 board CN1004 via the
CPC-13 Connecting jigs. (J-6082-443-A)
Channel 1: VC-543 board, CN1004 Pin ql (Note)
External trigger: VC-543 board, CN1004 Pin qj
Note:
Connect a 75 
Ω resistor between pins ql of CN1004
and w; (GND).
75 
Ω resistor (Parts code: 1-247-804-11)
5) Playback the alignment tape for tracking. (XH2-1) 
(Ref. No.
J-12)
6) Select page: 3, address: 33, and set data: 08.
7) Select page: 3, address: 26, set data: 31, and press the PAUSE
(Write) button.
8) Check that the oscilloscope RF waveform is normal at the en-
trance and exit.
If not normal, adjust according to the separate volume
“DV MECHANICAL ADJUSTMENT MANUAL IX
 N Mechanism ”.
6-53
HDR-FX1000/FX1000E_ADJ
Fig. 6-3-1
3-1-3.
Connecting the Equipment
Connect the measuring instruments as shown in Fig. 6-3-1, and
perform the adjustments.
6-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
3-1-1.
Precautions on Adjusting
Note:
Before performing the adjustment, check the data of page:
0, address: 10 is “00”. If not, select page: 0, address: 00,
and set data “00”.
1) The adjustments of this unit are performed in the VTR mode
(VCR mode) or camera mode (CAMERA mode).
3-1-2.
Adjusting Connectors
The measuring point of the playback RF signal is CN1004 of VC-
543 board. Connect the measuring instruments via the CPC-13 jig
(J-6082-443-A). Refer to “MECHANISM SECTION ADJUST-
MENT” for the measuring method. The following table lists the
test pin numbers of CPC-13 jig, and the pin numbers and signal
names of CN1004.
Pin No.
Signal Name
Pin No.
Signal Name
1
XSYS_RST
11
EEP_SI_S
2
XCS_MC_FLASH
12
EEP_SI_C
3
XCS_MC_FLASH_C 13
GND
4
MD2
14
GND
5
MD2_C
15
REG_GND
6
D_2.8V
16
FRRV
7
EEP_SCK_S
17
SWP
8
EEP_SCK_C
18
REG_GND
9
EEP_SO_S
19
RF_MON
10
EEP_SO_C
20
REG_GND
Table 6-3-1
A/V Connecting Cable (1.5 m)
(with S Video terminal)
(1-823-156-13)
HDMI OUT
 A/V R
LANC jack
Note: The pin arrangement is reverse between 
CN1004 of VC-543 board and CPC-13 jig. 
Accordingly, be careful when inserting the 
connector.
A/V R connector
Audio L (White)
S Video
(Black)
Video
(Yellow)
Audio R (Red)
VIDEO system adjustment (S VIDEO, VIDEO)
To
AC adaptor
(AC-L100)
1
20
Terminated
75 
20
1
CN1004
VC543 board
Adjustment remote commander
RM-95
(J-6082-053-B)
NEW LANC JIG
(J-6082-565-A)
LANC cable
(J-6082-442-A)
Oscilloscope
CPC-13 jig
(J-6082-443-A)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
6-54
HDR-FX1000/FX1000E_ADJ
3-1-4.
Alignment Tapes
Use the alignment tapes shown in the following table.
Use tapes specified in the signal column of each adjustment.
Name
Use
Tracking tape (XH2-1)
Tape path adjustment
SW/OL standard (XH2-3)
Switching position adjust-
ment
Audio operation check
Audio system adjustment
(XH5-3 (NTSC), XH5-3P (PAL))
System operation check
Operation check
(XH5-5 (NTSC), XH5-5P (PAL))
Fig. 6-3-2 shows the 75% color bar signals recorded on the align-
ment tape for Audio Operation Check.
Note:
 Measure with video terminal (Terminated at 75 
Ω)
Fig. 6-3-2 Color bar signal of alignment tapes
For NTSC model
For PAL model
Color bar signal waveform
Color bar pattern
Color bar signal waveform
Color bar pattern
3-1-5.
Output Level and Impedance
A/V OUT jack
10-pin connector
Video signal: 1 Vp-p, 75 
Ω (ohms)
Luminance signal: 1 Vp-p, 75 
Ω (ohms)
Chrominance signal: 0.286 Vp-p (burst signal), 75 
Ω (ohms)
(NTSC)
Chrominance signal: 0.3 Vp-p (burst signal), 75 
Ω (ohms)
(PAL)
Audio signal: -10 dBu (at load impedance 47 k
Ω (kilohms)),
Output impedance with less than 2.2 k
Ω (kilohms)
(0 dBu=0.775 Vrms)
COMPONENT OUT jack
Y: 1 Vp-p, 75 
Ω (ohms), P
B
/P
R
, C
B
/C
R
: +/- 350 mV, 75 
(ohms)
1 V
0.714 V
0.286 V
White (75%)
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
0.286 V
Q
I
Horizontal sync signal
(75%)
White
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Q
I
White
(100%)
Black
1 V
0.7 V
0.3 V
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
Horizontal sync signal
0.3 V
(100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
White
Blac
k
6-55
HDR-FX1000/FX1000E_ADJ
D
1
 (decimal)
D
2
 (decimal)
H
1
 (hexadecimal)
(Service model code)
00001 to 65535
D
1
FE
65536 to 131071
D
1
 
− 65536
FE
131072 to196607
D
1
 
− 131072
FE
196608 to 262143
D
1
 
− 196608
FE
262144 to 327679
D
1
 
− 262144
FE
327680 to 393215
D
1
 
− 327680
FE
393216 to 458751
D
1
 
− 393216
FE
458752 to 524287
D
1
 
− 458752
FE
524288 to 589823
D
1
 
− 524288
FE
589824 to 655359
D
1
 
− 589824
FE
655360 to 720895
D
1
 
− 655360
FE
720896 to 786431
D
1
 
− 720896
FE
786432 to 851967
D
1
 
− 786432
FE
851968 to 917503
D
1
 
− 851968
FE
917504 to 983039
D
1
 
− 917504
FE
983040 to 999999
D
1
 
− 983040
FE
Table 6-3-2
5) Enter H
1
 to address: 09 on page: 13.
Example: If H
1
 = FE,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 09, and set data: FE, then press
the PAUSE (Write) button.
6) From Table 6-3-3, obtain the maximum decimal number less
than D
2
, and it is assumed to be D
3
.
Example: If D
2
 = 12345.
D
3
 = 12288
7) From Table 6-3-3, obtain a hexadecimal number that corre-
sponds to D
3
, and it is assumed to be H
3
.
Example: If D
3
 = 12288,
H
3
 = 3000
8) Caluculate D
4
  using following equa tions (decimal
caluculation). (0   D
4
 
 225)
D
4
 = D
2
 – D
3
Example: If D
2
 = 12345 and D
3
 = 12288,
D
4
 = 12345 – 12288 = 57
9) Convert D
4
 into a hexadecimal number to obtain H
4
. (See Table
6-4-1 “Hexadecimal - decimal conversion table” in 6-4. Ser-
vice Mode)
Example: If D
4
 = 57,
H
4
 = 39
10) Enter higher two digits of H
3
 to address: 0A on page: 13.
Example: If H
3
 = 3000,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 0A, and set data: 30, then press
the PAUSE (Write) button.
11) Enter H
4
 to address: 0B on page: 13.
Example: If H
4
 = 39,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 0B, and set data: 39, then press
the PAUSE (Write) button.
12) Select page: 0, address: 10, and set data: 00.
13) Select page: 3, address: 70, and set data: 10, then press the
PAUSE (Write) button.
14) Select page: 3, address: 70, and check that the data changes to
“11”.
15) Select page: 0, address: 01, and set data: 00.
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENTS
1.
Initialization of EEPROM Data
If the EEPROM data is erased due to some reason, perform “1-2.
INITIALIZATION OF EVR DATA ”, of “6-1. CAMERA SEC-
TION ADJUSTMENTS”
2.
Node Unique ID No. Input
Note 1:
Perform “2-2. Input of Serial No.” if the data on page 13
has been cleared and original node unique ID No. is un-
certain.
Usually, read the data on page 13 before repair, and write
it after repair.
Note 2:
If reading/writing data on pages 13, set data: 01 to page:
0, address: 10, and then select pages: 3. By this data set-
ting, the pages 13 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
2-1. Input of Company ID
Write the company ID to the EEPROM (nonvolatile memory).
Page
13
Address
04, 05, 06, 07
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 71, and set data: 01, then press the
PAUSE (Write) button.
3) Select page: 0, address: 10, and set data: 01.
4) Select page: 3 (13), and enter the following data.
Note 3:
Each time the data is set, press the PAUSE (Write) but-
ton on the adjusting remote commander.
Address
Data
04
08
05
00
06
46
07
01
 5)Select page: 0, address: 10, and set data: 00.
6) Select page: 3, address: 70, and set data: 10, then press the
PAUSE (Write) button.
7) Select page: 3, address: 70, and check that the data changes to
“11”.
8) Select page: 0, address: 01, and set data: 00.
2-2. Input of Serial No.
Write the serial No. and model code to the EEPROM (nonvolatile
memory).
In writing the serial No., a decimal number should be converted
into a hexadecimal number
Page
13
Address
08, 09, 0A, 0B
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 71, and set data: 01, then press the
PAUSE (Write) button.
3) Read the serial No. from the model name label, and it is as-
sumed to be D
1
.
Example: If serial No. is “77881”,
D
1
 = 77881
4) From Table 6-3-2, obtain D
2
 and H
1
 that correspond to D
1
.
Example: If D
1
 = 77881,
D
2
 = D
1
 – 65536 = 12345
H
1
 = FE
Page of 81
Display