Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-40
HDR-FX1000/FX1000E_ADJ
22. Auto White Balance Standard Data Input
(ND2) 
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart (Color reproduction
adjustment frame)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
90 to 93
Specified Value
Data of page: 6 address: 0C is “00”
Note 1:
Perform “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
99
Check the data is “02”.
3
6
02
Check the data is “00”.
4
6
07
Check the data is “04”.
5
6
40
01
6
6
41
01
7
6
01
0B
Press PAUSE (Write) button.
(Note 4)
8
6
02
Check the data changes to
“01”.
9
6
0C
Check the data is “00”.
Note 4:
The adjustment data will be automatically input to page:
6F, address: 90 to 93.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
40
00
3
6
41
00
4
0
01
00
23. Auto White Balance Adjustment (ND2) 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6F
Adjustment Address
A0 to A3
Note 1:
Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
0
01
01
3
6
99
Check the data is “02”.
4
6
02
Check the data is “00”.
5
6
07
Check the data is “04”.
6
6
40
01
7
6
41
01
8
6
13
BF
9
6
01
81
Press PAUSE (Write) button.
(Note 4)
10
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
6F, address: A0 to A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
40
00
3
6
41
00
4
6
13
00
5
0
01
00
6
Remove the C14 filter on the
lens.
6-41
HDR-FX1000/FX1000E_ADJ
24. Auto White Balance Check (ND2) 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Clear chart (Color reproduction
adjustment frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: 0C is “00”
Note 1:
Perform “Auto White Balance Standard Data Input
(ND2)”, “LV Standard Data Input” and “Auto White Bal-
ance Adjustment (ND2)” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
Procedure
1
0
01
01
2
6
9B
Check the bit value of bit2 is
“0”. (Note 3)
3
6
99
Check the data is “02”.
4
6
07
Check the data is “04”.
5
6
40
01
6
6
41
01
7
6
CA
85
8
6
C9
10
 
OUTDOOR white balance check
9
6
01
4F
Press PAUSE (Write) button.
10
6
02
Check the data changes to
“01”.
11
6
0C
Check the data is “00”.
12
6
01
00
Press PAUSE (Write) button.
 
INDOOR white balance check
13
6
01
0F
Press PAUSE (Write) button.
14
6
02
Check the data changes to
“01”.
15
6
0C
Check the data is “00”.
16
6
01
00
Press PAUSE (Write) button.
Order Page Address Data
Procedure
 
InOut check
17
Place the ND filter 1.5 (1.0
+0.4 + 0.1) on the lens.
18
6
C9
11
19
6
13
BF
20
Wait for 1 second.
21
6
01
4B
Press PAUSE (Write) button.
22
6
02
Check the data changes to
“01”.
23
6
0C
Check the data is “00”.
24
6
01
00
Press PAUSE (Write) button.
25
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
C9
00
2
6
CA
00
3
6
40
00
4
6
41
00
5
6
13
00
6
0
01
00
6-42
HDR-FX1000/FX1000E_ADJ
25. Auto White Balance Standard Data Input
(ND3) 
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart (Color reproduction
adjustment frame)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
94 to 97
Specified Value
Data of page: 6 address: 0C is “00”
Note 1:
Perform “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
99
Check the data is “03”.
3
6
02
Check the data is “00”.
4
6
07
Check the data is “04”.”
5
6
40
01
6
6
41
01
7
6
13
BF
8
6
01
0B
Press PAUSE (Write) button.
(Note 4)
9
6
02
Check the data changes to
“01”.
10
6
0C
Check the data is “00”.
Note 4:
The adjustment data will be automatically input to page:
6F, address: 94 to 97.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
40
00
3
6
41
00
4
6
13
00
5
0
01
00
26. Auto White Balance Adjustment (ND3) 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6F
Adjustment Address
A4 to A7
Note 1:
Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
0
01
01
3
6
99
Check the data is “03”.
4
6
02
Check the data is “00”.
5
6
07
Check the data is “04”.
6
6
40
01
7
6
41
01
8
6
13
BD
9
6
01
81
Press PAUSE (Write) button.
(Note 4)
10
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
6F, address: A4 to A7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
40
00
3
6
41
00
4
6
13
00
5
0
01
00
6
Remove the C14 filter on the
lens.
6-43
HDR-FX1000/FX1000E_ADJ
27. Auto White Balance Check (ND3) 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Clear chart (Color reproduction
adjustment frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: 0C is “00”
Note 1:
Perform “Auto White Balance Standard Data Input
(ND3)”, “LV Standard Data Input” and “Auto White Bal-
ance Adjustment (ND3)” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
Procedure
1
0
01
01
2
6
9B
Check the bit value of bit2 is
“0”. (Note 3)
3
6
99
Check the data is “03”.
4
6
07
Check the data is “04”.
5
6
40
01
6
6
41
01
7
6
CA
85
8
6
C9
10
9
6
13
BF
 
OUTDOOR white balance check
10
6
01
4F
Press PAUSE (Write) button.
11
6
02
Check the data changes to
“01”.
12
6
0C
Check the data is “00”.
13
6
01
00
Press PAUSE (Write) button.
 
INDOOR white balance check
14
6
01
0F
Press PAUSE (Write) button.
15
6
02
Check the data changes to
“01”.
16
6
0C
Check the data is “00”.
17
6
01
00
Press PAUSE (Write) button.
Order Page Address Data
Procedure
 InOut check
18
Place the ND filter 1.5 (1.0
+0.4 + 0.1) on the lens.
19
6
C9
11
20
6
13
BE
21
Wait for 3 seconds.
22
6
01
4B
Press PAUSE (Write) button.
23
6
02
Check the data changes to
“01”.
24
6
0C
Check the data is “00”.
25
6
01
00
Press PAUSE (Write) button.
26
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
C9
00
2
6
CA
00
3
6
40
00
4
6
41
00
5
6
13
00
6
0
01
00
Page of 81
Display

Click on the first or last page to see other HDR-FX1000 / HDR-FX1000E (serv.man3) service manuals if exist.