DOWNLOAD Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ↓ Size: 1.02 MB | Pages: 81 in PDF or view online for FREE

Model
HDR-FX1000 HDR-FX1000E (serv.man3)
Pages
81
Size
1.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-28
HDR-FX1000/FX1000E_ADJ
5.
Zoom Ring Adjustment (MR Sensor)
The manual zoom ring MR adjustment is carried out automati-
cally.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6D
6E
Adjustment Address
A9 to AC, AF
FC to FF
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6D, 6E, set data: 06 to
page: 0, address: 10, and then select pages D, E. By this
data setting, the pages 6D, 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 3)
Turn the zoom ring manually
in one direction slowly.
3
It should be turning several
times.
Continue to turn till the end of
adjustment.
4
6
01
5B
Press PAUSE (Write) button.
(Note 4)
5
6
02
Check the data changes to “01”.
6
Wait for 10 seconds.
7
6
0C
Check the data is “00”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
6D, address: A9 to AC, AF and page: 6E, address: FC to
FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
RadarW
RadarW
RadarW
6.
Focus Ring Adjustment (MR Sensor)
The manual focus ring MR adjustment is carried out automati-
cally.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6D
6E
Adjustment Address
A5 to A8, AD to AF
FA, FB
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6D, 6E, set data: 06 to
page: 0, address: 10, and then select pages D, F. By this
data setting, the pages 6D, 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 3)
Turn the focus ring manually
in one direction slowly.
3
It should be turning several
times.
Continue to turn till the end of
adjustment.
4
6
01
59
Press PAUSE (Write) button.
(Note 4)
5
6
02
Check the data changes to “01”.
6
Wait for 10 seconds.
7
6
0C
Check the data is “00”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
6D, address: A5 to A8, AD to AF and page: 6E, address:
FA, FB.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
RadarW
RadarW
RadarW
RadarW
RadarW
6-29
HDR-FX1000/FX1000E_ADJ
7.
Flange Back Adjustment
(Using the minipattern box or flange back adjustment
jig)
[Preparation (Using the minipattern box)]
1) The minipattern box is installed as shown in the following fig-
ure.
Note:
 The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-6
[Preparation (Using the flange back adjustment jig)]
(Illuminance: 550 to 650 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-7
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
7-1. Flange Back Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the minipattern box or flange back adjust-
ment jig)
Perform the flange back adjustment. In whichever case, the focus
will be deviated during auto focusing/manual focusing.
Subject
Siemens star chart for minipattern
box (Note 1) or flange back
adjustment jig
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
20 to 3F
Specified value
Data of pege: 6, address: 0C is “00”
Note 1:
Dark Siemens star chart.
Note 2:
Perform “PSD Sensor Gradient Adjustment”, “Lens Ad-
justment”, “Zoom Ring Adjustment”, “Focus Ring Ad-
justment” 
before 
this adjustment.
Note 3:
Perform the adjustment with the lens in horizontal state.
Note 4:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 5:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6:
Don't touch the zoom ring during adjustment.
Note 7:
After adjustment, if the focusing to a subject located at
infinity failed, increase the ilIlluminance of the chart and
perform readjustment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
The changed portions from
Ver. 1.2 are shown in blue.
Ver. 1.3  2011.05
6-30
HDR-FX1000/FX1000E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
61
01
3
Wait for 3 seconds.
4
0
10
09
5
F
4A
83
(9F)
6
F
4B
80
(Note 10)
(9F)
7
0
10
00
8
6
02
Check the data is “00”.
9
6
99
Check the data is “00”.
10
6
4D
40
11
6
64
04
12
0
10
07
13
E
10
Set the bit value of bit1 is “0”,
(7E)
and press PAUSE (Write)
button. (Note 8)
14
0
10
00
15
6
40
01
16
6
01
13
Press PAUSE (Write) button.
17
Wait for 1 seconds.
18
6
01
27
Press PAUSE (Write) button.
19
6
02
Check the data changes to
“01”.
20
6
0C
Check the data is “00”.
Note 8:
For the bit values, refer to “6-4. SERVICE MODE”,
“4-4. 3. Bit value discrimination”.
Note 9:
The adjustment data will be automatically input to page:
6F, address: 20 to 3F.
Note 10:
The center line portion of chart should be in the AF
detection frame “A” at the TELE end.
Fig. 6-1-8
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
64
00
3
6
4D
00
4
6
40
00
5
0
10
07
6
E
10
Set the bit value of bit1 is “1”,
(7E)
and press PAUSE (Write)
button. (Note 7)
7
0
10
00
8
6
61
00
9
Wait for 3 seconds.
10
0
10
09
11
F
4A
00
(9F)
12
F
4B
00
(9F)
13
0
10
00
14
6
01
25
Press PAUSE (Write) button.
15
6
02
Check the data changes to
“01”.
16
6
01
00
Press PAUSE (Write) button.
17
0
01
00
7-2. Optical Axis Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Correct the disorder of the center axis of the optical system.
Adjustment Page
7F
Adjustment Address
30 to 3F
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 07.
3) Input the following data to page: F (7F), address: 30 to 3F.
Note:
Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
30
00
31
00
32
00
33
00
34
00
35
00
36
00
37
00
38
00
39
00
3A
00
3B
00
3C
00
3D
00
3E
00
3F
00
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
AF detection frame “A”
6-31
HDR-FX1000/FX1000E_ADJ
9.
Black Balance Adjustment 
RadarW
RadarW
RadarW
Adjust the black level.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6E
Adjustment Address
C6 to EF
Note 1:
If reading/writing data on pages 6E, set data: 06 to
page: 0, address: 10, and then select pages E. By this
data setting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Check that the data of page: 6, address: 02 is “00”
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “04”.
3
6
07
Check the data is “04”.
4
6
01
BF
Press PAUSE (Write) button.
(Note 3)
5
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
6E, address: C6 to EF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
8
.
Flange Back Check
(Using the flange back adjustment jig)
Subject
Flange back adjustment jig
(Illuminance: approx. 300 
± 50 lux)
(Used siemens star chart)
Measurement Point
Check operation on monitor TV
Measuring Instrument
(Note 2)
Specified value
Focused at the TELE end and WIDE
end
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check with the monitor larger than 40 inches.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
Procedure
1
Shoot the chart with the
zoom TELE end.
2
0
01
01
3
6
61
01
4
Wait for 3 seconds.
5
6
2C
02
6
6
40
01
7
6
41
01
8
6
4D
40
9
6
01
13
Press PAUSE (Write) button.
10
Wait for 1 second.
11
Check that the lens is
focused while zooming from
TELE end to WIDE end.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
2C
00
3
6
40
00
4
6
41
00
5
6
4D
00
6
6
61
00
7
Wait for 3 seconds.
8
0
01
00
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
Page of 81
Display

Click on the first or last page to see other HDR-FX1000 / HDR-FX1000E (serv.man3) service manuals if exist.