DOWNLOAD Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ↓ Size: 1.02 MB | Pages: 81 in PDF or view online for FREE

Model
HDR-FX1000 HDR-FX1000E (serv.man3)
Pages
81
Size
1.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-16
HDR-FX1000/FX1000E_ADJ
1-2-3.
Initialization of Camera Control Page Data
1.
Initializing of Camera Control Page Data
Note 1:
If “Initialization of Camera Control Page Data” is ex-
ecuted, all data on camera control page are initialized.
(Only an individual page cannot be initialized)
Note 2:
If the camera control page data has been initialized, the
following adjustments need to be performed again.
1) Modification of camera control page data
2) Camera system adjustment (if all areas were initial-
ized)
Adjustment Page
6D
Adjustment Address
00 to F9
Adjustment Page
6E
Adjustment Address
00 to FF
Adjustment Page
6F
Adjustment Address
10 to FF
Adjustment Page
7C
Adjustment Address
00 to FF
Adjustment Page
7E
Adjustment Address
00 to FF
Adjustment Page
7F
Adjustment Address
00 to FF
Adjustment Page
8C
Adjustment Address
00 to F9
Adjustment Page
8D
Adjustment Address
00 to FF
Adjustment Page
8E
Adjustment Address
00 to FF
Adjustment Page
8F
Adjustment Address
00 to FF
Adjustment Page
9D
Adjustment Address
00 to 4F
Adjustment Page
9E
Adjustment Address
00 to FF
Adjustment Page
9F
Adjustment Address
00 to FF
Adjustment Page
AD
Adjustment Address
00 to 4F
Adjustment Page
AE
Adjustment Address
00 to F1
Adjustment Page
AF
Adjustment Address
00 to FF
Adjustment Page
BE
Adjustment Address
00 to F9
Adjustment Page
BF
Adjustment Address
00 to FF
Adjustment Page
C2
Adjustment Address
00 to FF
Adjustment Page
C3
Adjustment Address
00 to FF
Adjustment Page
C4
Adjustment Address
00 to FF
Adjustment Page
C5
Adjustment Address
00 to FF
Adjustment Page
C6
Adjustment Address
00 to DF
Adjustment Page
C7
Adjustment Address
00 to FF
Adjustment Page
C8
Adjustment Address
00 to FF
Adjustment Page
C9
Adjustment Address
00 to FF
Adjustment Page
CA
Adjustment Address
00 to FF
Adjustment Page
CB
Adjustment Address
00 to DF
Adjustment Page
CC
Adjustment Address
00 to C7
Adjustment Page
CD
Adjustment Address
00 to FF
Adjustment Page
CE
Adjustment Address
00 to FF
Adjustment Page
CF
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
2
EA
Check the bit1 value.
1: NTSC model
0: PAL model
4
6
01
Set the following data, and
press PAUSE (Write) button.
(Note 3)
NTSC model:
2D: Initializing all areas
31: Initializing other than
adjustment address
PAL model:
2F: Initializing all areas
33: Initializing other than
adjustment address
5
6
03
01
Press PAUSE (Write) button.
6
6
02
Check the data changes to
“01”.
7
6
01
00
Press PAUSE (Write) button.
8
0
10
7
9
2
01
Set the following data, and
press PAUSE (Write) button.
2D: Initializing all areas
31: Initializing other than
adjustment address
10
2
02
Check the data changes to
“01”.
11
2
01
00
Press PAUSE (Write) button.
12
0
10
00
13
Perform “Modification of
Camera Control Data”.
Note 3:
If other than adjustment address was initialized, the ad-
justed data is not initialized.
Note 4:
NTSC model: HDR-FX1000
PAL model: HDR-FX1000E
(72)
(72)
(72)
6-17
HDR-FX1000/FX1000E_ADJ
2.
Modification of Camera Control Page Data
If the camera control page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If 2-digit page is selected, set higher-order digit to page: 0,
address: 10 as data, and then select lower-order digit by a usual
method.
e.g.: Set data: 06 to page: 0, address: 10, and then select page:
D. Thus, the page 6D can be selected.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the cam-
corder may not operate.
4) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table. If different, change them to the adjustment
initial values.
6) Select page: 0, address: 01, set data: 01.
7) Select page: 3, address: 71, set data: 01, and press PAUSE
(Write) button.
Processing after Completing Modification Camera Control
Data:
Order Page Address Data
Procedure
1
0
10
00
2
3
70
10
Press PAUSE (Write) button.
3
3
70
Check the data changes to
“11”.
4
2
00
29
5
2
01
29
Press PAUSE (Write) button.
3.
6D Page table
Note 1:
If reading/writing data on pages 6D, set data: 06 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 6D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to 59
Fixed data-1 (Initialized data)
5A
00
00
STD gain adj.
5B
Fixed data-1 (Initialized data)
5C
36
36
LV Standard data input
5D
10
10
5E
0B
0B
MAX gain adj.
5F
6E
6E
60 to F9
Fixed data-1 (Initialized data)
Ver. 1.1  2008.11
6-18
HDR-FX1000/FX1000E_ADJ
4.
6E Page table
Note 1:
If reading/writing data on pages 6E, set data: 06 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
5.
6F Page table
Note 1:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
10 to FF
Fixed data-1 (Initialized data)
6.
7C Page table
Note 1:
If reading/writing data on pages 7C, set data: 07 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 7C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
7.
7E Page table
Note 1:
If reading/writing data on pages 7E, set data: 07 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 7E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
8.
7F Page table
Note 1:
If reading/writing data on pages 7F, set data: 07 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00
80
80
01
80
80
02
02
02
03
C2
C2
04
02
02
05
C2
C2
06
00
00
07
00
00
08
00
00
09
00
00
0A
00
00
0B
00
00
0C
00
00
0D
00
00
0E
00
00
0F
00
00
PSD Sensor Gradient Adjustment
10
00
00
11
00
00
12
00
00
13
00
00
14
00
00
15
00
00
16
00
00
17
00
00
18
00
00
19
00
00
1A
00
00
1B
00
00
1C
00
00
1D
00
00
1E
00
00
1F
00
00
20
60
60
Angular Velocity Sensor Sensitivity
21
60
60
Adjustment
22 to 7F
Fixed data-1 (Initialized data)
6-19
HDR-FX1000/FX1000E_ADJ
9.
8C Page table
Note 1:
If reading/writing data on pages 8C, set data: 08 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 8C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to 45
Fixed data-1 (Initialized data)
46
Fixed data-2
47 to DE
Fixed data-1 (Initialized data)
DF
Fixed data-2
E0
Fixed data-1 (Initialized data)
E1
Fixed data-2
E2 to F9
Fixed data-1 (Initialized data)
10. 8D Page table
Note 1:
If reading/writing data on pages 8D, set data: 08 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 8D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
11. 8E Page table
Note 1:
If reading/writing data on pages 8E, set data: 08 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 8E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to 08
Fixed data-1 (Initialized data)
09 to 0E
Fixed data-2
0F, 10
Fixed data-1 (Initialized data)
11 to 16
Fixed data-2
17, 18
Fixed data-1 (Initialized data)
19 to 1C
Fixed data-2
1D
Fixed data-1 (Initialized data)
1E
Fixed data-2
1F, 20
Fixed data-1 (Initialized data)
21 to 24
Fixed data-2
25
Fixed data-1 (Initialized data)
26
Fixed data-2
27, 28
Fixed data-1 (Initialized data)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
Page of 81
Display