Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-12
HDR-FX1000/FX1000E_ADJ
4.
9 Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
3.
8 Page table
Note 1:
Check that the data of page: 0, address: 10 is“00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to F1
Fixed data-1 (Initialized data)
F2
Fixed data-2
F3 to FF
Fixed data-1 (Initialized data)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
6-13
HDR-FX1000/FX1000E_ADJ
5.
C Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
10
EE
EE
11
00
00
Switching position adj.
12
00
00
13
00
00
14, 15
Fixed data-1 (Initialized data)
16
E0
E0
CAP FG duty adj.
17 to 24
Fixed data-1 (Initialized data)
25
70
-
S VIDEO OUT Y level adj.
(NTSC)/Fixed data-1 (PAL)
26
8A
-
S VIDEO OUT chroma level adj.
27
61
-
(NTSC)/Fixed data-1 (PAL)
28 to 7D
Fixed data-1 (Initialized data)
7E
-
70
Fixed data-1(NTSC)/S VIDEO OUT
Y level adj. (PAL)
7F
-
8A
Fixed data-1(NTSC)/S VIDEO OUT
80
-
61
chroma level adj. (PAL)
81to 8B
Fixed data-1 (Initialized data)
8C
79
79
COMPONENT OUT Y level adj.
8D
31
31
COMPONENT OUT Pb level adj.
8E
32
32
COMPONENT OUT Pr level adj.
8F to A0
Fixed data-1 (Initialized data)
A1
70
70
V-COM adj. (LCD)
A2
20
20
Transmissive mode white balance
A3
20
20
adj. (LCD)
A4, A5
Fixed data-1 (Initialized data)
A6
80
80
A7
80
80
PANEL gain adj.
A8
80
80
A9
80
80
AA
80
80
AB
80
80
EVF gain adj.
AC
37
37
AD
37
37
AE
37
37
AF
37
37
B0
37
37
PANEL gain adj.
B1
37
37
Address
Initial value
Remark
NTSC PAL
B2
00
00
B3
00
00
B4
00
00
B5
00
00
B6
00
00
B7
80
80
B8
00
00
B9
00
00
BA
00
00
BB
00
00
BC
00
00
BD
00
00
Error rate check
BE
00
00
BF
00
00
C0
00
00
C1
00
00
C2
80
80
C3
00
00
C4
00
00
C5
00
00
C6
00
00
C7
00
00
C8 to EA
Fixed data-1 (Initialized data)
EB
00
00
Est Error Code
EC to F3
Fixed data-2
F4
00
00
F5
00
00
F6
00
00
F7
00
00
F8
00
00
F9
00
00
Emergence memory address
FA
00
00
(Mechanism section)
FB
00
00
FC
00
00
FD
00
00
FE
00
00
FF
00
00
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
6-14
HDR-FX1000/FX1000E_ADJ
6.
13 Page table
Note 1:
If reading/writing data on pages 13, set data: 01 to page:
0, address: 10, and then select pages: 3. By this data set-
ting, the pages 13 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 03
Fixed data-1 (Initialized data)
04
08
08
05
00
00
06
46
46
07
01
01
Node unique ID No. input
08
02
02
09
00
00
0A
00
00
0B
00
00
0C
48
48
0D
44
44
0E
52
52
0F
2D
2D
10
46
46
11
58
58
Model Name (SDD data)
12
31
31
13
30
30
14
30
30
15
30
30
16
45
17
00
00
18 to 23
Fixed data-1 (Initialized data)
24
01
01
Module No.
25
7F
Fixed data-1 (NTSC)/
Module No. (PAL)
26 to FF
Fixed data-1 (Initialized data)
7.
18 Page table
Note 1:
If reading/writing data on pages 18, set data: 01 to page:
0, address: 10, and then select pages: 8. By this data set-
ting, the pages 18 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to DD
Fixed data-1 (Initialized data)
DE
Fixed data-2
DF to FF
Fixed data-1 (Initialized data)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
6-15
HDR-FX1000/FX1000E_ADJ
8.
1C Page table
Note 1:
If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to“00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
9.
1D Page table
Note 1:
If reading/writing data on pages 1D, set data: 01 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 1D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
10. 1E Page table
Note 1:
If reading/writing data on pages 1E, set data: 01 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 1E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 65
Fixed data-1 (Initialized data)
66
Fixed data-2
67 to 81
Fixed data-1 (Initialized data)
82
Fixed data-2
83, 84
Fixed data-1 (Initialized data)
85, 86
Fixed data-2
87 to FF
Fixed data-1 (Initialized data)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
Page of 81
Display

Click on the first or last page to see other HDR-FX1000 / HDR-FX1000E (serv.man3) service manuals if exist.