DOWNLOAD Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ↓ Size: 1.02 MB | Pages: 81 in PDF or view online for FREE

Model
HDR-FX1000 HDR-FX1000E (serv.man3)
Pages
81
Size
1.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1000-hdr-fx1000e-sm3.pdf
Date

Sony HDR-FX1000 / HDR-FX1000E (serv.man3) Service Manual ▷ View online

6-24
HDR-FX1000/FX1000E_ADJ
32. CD Page table
Note 1:
If reading/writing data on pages CD, set data: 0C to page:
0, address: 10, and then select pages: D. By this data
setting, the pages CD can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to 11
Fixed data-1 (Initialized data)
12
Fixed data-2
13 to 1C
Fixed data-1 (Initialized data)
1D
Fixed data-2
 1E to 2F
Fixed data-1 (Initialized data)
30 to 32
Fixed data-2
33
Fixed data-1 (Initialized data)
34, 35
Fixed data-2
36
Fixed data-1 (Initialized data)
37 to 3A
Fixed data-2
3B
Fixed data-1 (Initialized data)
3C, 3D
Fixed data-2
3E
Fixed data-1 (Initialized data)
3F
Fixed data-2
 40 to 4F
Fixed data-1 (Initialized data)
50
Fixed data-2
51 to 53
Fixed data-1 (Initialized data)
54 to 57
Fixed data-2
 58 to 87
Fixed data-1 (Initialized data)
88 to 95
Fixed data-2
96 to 99
Fixed data-1 (Initialized data)
9A to A3
Fixed data-2
A4, A5
Fixed data-1 (Initialized data)
A6 to AB
Fixed data-2
AC, AD
Fixed data-1 (Initialized data)
AE to B3
Fixed data-2
B4, B5
Fixed data-1 (Initialized data)
B6 to B9
Fixed data-2
BA to BE
Fixed data-1 (Initialized data)
BF
Fixed data-2
C0 to C2
Fixed data-1 (Initialized data)
C3
Fixed data-2
C4
Fixed data-1 (Initialized data)
C5
Fixed data-2
C6
Fixed data-1 (Initialized data)
C7
Fixed data-2
C8
Fixed data-1 (Initialized data)
C9
Fixed data-2
CA
Fixed data-1 (Initialized data)
Address
Initial value
Remark
NTSC PAL
CB
Fixed data-2
CC
Fixed data-1 (Initialized data)
CD
Fixed data-2
CE
Fixed data-1 (Initialized data)
CF
Fixed data-2
D0 to FF
Fixed data-1 (Initialized data)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
6-25
HDR-FX1000/FX1000E_ADJ
33. CE Page table
Note 1:
If reading/writing data on pages CE, set data: 0C to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages CE can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
NTSC PAL
00 to 03
Fixed data-1 (Initialized data)
04
Fixed data-2
 05 to 0F
Fixed data-1 (Initialized data)
10 to 13
Fixed data-2
 14 to 1D
Fixed data-1 (Initialized data)
1E, 1F
Fixed data-2
20 to 22
Fixed data-1 (Initialized data)
23, 24
Fixed data-2
25
Fixed data-1 (Initialized data)
26
Fixed data-2
27 to 2A
Fixed data-1 (Initialized data)
2B, 2C
Fixed data-2
2D
Fixed data-1 (Initialized data)
2E to 31
Fixed data-2
32
Fixed data-1 (Initialized data)
33
Fixed data-2
34
Fixed data-1 (Initialized data)
35, 36
Fixed data-2
37 to 3A
Fixed data-1 (Initialized data)
3B, 3C
Fixed data-2
3D to 5C
Fixed data-1 (Initialized data)
5D
Fixed data-2
 5E to 79
Fixed data-1 (Initialized data)
7A to 7D
Fixed data-2
7E to 83
Fixed data-1 (Initialized data)
84, 85
Fixed data-2
86 to 91
Fixed data-1 (Initialized data)
92, 93
Fixed data-2
94 to 97
Fixed data-1 (Initialized data)
98 to 
9D
Fixed data-2
9E
Fixed data-1 (Initialized data)
9F
Fixed data-2
A0 to C1
Fixed data-1 (Initialized data)
C2 to C5
Fixed data-2
C6 to EE
Fixed data-1 (Initialized data)
EF
Fixed data-2
F0 to FF
Fixed data-1 (Initialized data)
Address
Initial value
Remark
NTSC PAL
00 to 8F
Fixed data-1 (Initialized data)
90 to 9F
Fixed data-2
A0 to 
B0
Fixed data-1 (Initialized data)
B1 to BD
Fixed data-2
BE
Fixed data-1 (Initialized data)
BF
Fixed data-2
C0 to C7
Fixed data-1 (Initialized data)
C8 to CF
Fixed data-2
D0 to E8
Fixed data-1 (Initialized data)
E9
Fixed data-2
EA
Fixed data-1 (Initialized data)
EB to EF
Fixed data-2
F0 to FF
Fixed data-1 (Initialized data)
34. CF Page table
Note 1:
If reading/writing data on pages CF, set data: 0C to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages CF can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.11
6-26
HDR-FX1000/FX1000E_ADJ
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except Origin Oscillation Check”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1-3-1. Camera System Adjustments
1.
Origin Oscillation Check (VC-543 board)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
R1414 (CHCK) on VC-543 board
Measuring Instrument
Frequency counter
Specified value
f = 41538461 
± 835 Hz (NTSC)
f = 41580000 
± 835 Hz (PAL)
Switch setting
1) POWER ......................................................... CAMERA mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Fig. 6-1-5
IC1601
IC1401
R1414
VC-543 BOARD (SIDE A)
2.
Coaxial Harness Connecting Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Check if the coaxial harness of CMOS is connected correctly.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6
Adjustment Address
D1 to D6
Specified value
Data of page: 6, address: D0 is “07”
Note 1:
Check that the data of page: 6, address: 02 is “00”
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
07
Check the data is “04”.
3
0
10
09
4
E
90
10
(9E)
5
E
80
00
(9E)
6
0
10
00
7
6
01
EB
Press PAUSE (Write)
button.(Note 2)
8
6
02
Check the data changes to
“01”.
9
6
D0
Check the data is “07”.
(Note 3)
Note 2:
The adjustment data will be automatically input to page:
6, address: D1 to D6.
Note 3:
For the error codes of bit 0 to bit 2 of data of page: 6,
address: D0, see the following table.
Bit value of data of
Error contents
page: 6,
address: D0
Bit
Function
When bit value = 0 When bit value = 1
0
R
Error exists
No error
1
G
Error exists
No error
2
B
Error exists
No error
Example: If an error exists in G, data is “05”
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
10
09
3
E
90
00
(9E)
4
E
80
70
(9E)
5
0
10
00
6
0
01
00
6-27
HDR-FX1000/FX1000E_ADJ
3.
PSD Sensor Gradient Adjustment (VC-543 board)
Input average offset voltage of the YAW (SE8502)/PITCH
(SE8501) sensors on GY-014 board.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
7F
Adjustment Address
00 to 1F
Specified value
Data of page: 72, address: 02 is “01”
Note 1:
Set the camera on a horizontal table.
Note 2:
Check that the data of page: 72, address: 02 is “00”
If not, select page: 72, address: 01, set data: 00, and press
the PAUSE (Write) button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
7
3
2
01
97
Press PAUSE (Write) button.
(72)
(Note 3)
4
Wait for 6 seconds.
5
2
02
Check the data changes to
(72)
“01”. (Note 4)
6
F
16
Check the data changes to
(7F)
“11”.
7
2
01
00
Press PAUSE (Write) button.
(72)
8
0
10
00
9
0
01
00
Note 3:
The adjustment data will be automatically input to page:
7F, address: 00 to 1F.
Note 4:
If the data is other than “01”, adjustment has errors.
Contents of error is written into page: 7F, address: 16.
See the following table.
Data of page: 7F,
Error contents
address: 16
X, Y = 0
In the middle of adjustment
X, Y = 2
Abnormal termination
X, Y = 1
Normal termination
RadarW
RadarW
RadarW
4.
Lens Adjustment
The inner focus lens MR adjustment is carried out automatically.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
30, 40 to 4F
Specified value
Data of page: 6, address: 0C is “00”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Perform “Flange Back Adjustment ” after this adjustment.
Note 3:
If reading/writing data on page 6F, set data: 06 to page:
0, address: 10, and then select page F. By this data set-
ting, the page 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 4)
3
6
01
BD
Press PAUSE (Write) button.
(Note 5)
4
6
02
Check the data changes to “01”.
5
6
0C
Check the data is “00”.
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 5:
The adjustment data will be automatically input to page:
6F, address: 30, 40 to 4F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE (Write) button.
5
0
01
00
“X, Y”: X: High 4 bits Yaw sensor
             Y: Low 4 bits Pitch sensor
RadarW
RadarW
RadarW
Page of 81
Display

Click on the first or last page to see other HDR-FX1000 / HDR-FX1000E (serv.man3) service manuals if exist.