DOWNLOAD Sony DCR-TRV9 / DCR-TRV9E Service Manual ↓ Size: 34.67 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV9 DCR-TRV9E
Pages
127
Size
34.67 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M DCR-TRV9/TRV9E 98 US CAN E
File
dcr-trv9-dcr-trv9e.pdf
Date

Sony DCR-TRV9 / DCR-TRV9E Service Manual ▷ View online

5-54
16. IC9004 EVR CB Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the CB AD OUT level.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
D
Adjustment Address
9D
Specified Value
4D to 4F (NTSC)
53 to 55 (PAL)
Note 1:
The two digits of the display data of the LCD and TV monitor is
the object data.
 HI XX XXXX
Object data
Note 2:
Use the 75% color bar signal shown in Fig. 5-3-17.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 40.
4)
Select page: 2, address: 97, and set data: C0 (NTSC) or B0
(PAL).
5)
Select page: D, address: 9D, change the data and adjust the
DDS display data (Note 1) to the specified value.
6)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
5-55
3-5-4.
BIST Check
1. Playback System Check
1)
Set the POWER switch to VTR (or PLAYER) position.
2)
Connect the adjustment remote commander and set the HOLD
switch to HOLD (SERVICE) position.
3)
Playback the BIST check tape. (XH5-6 (NTSC), XH5-6P
(PAL))
IC1701 (D1) Playback System Check
4)
Select page: 4, address: 11, and set data: 04, then press the
PAUSE button.
5)
Select page: 4, address: 11, and set data: 00, then press the
PAUSE button.
6)
Select page: 4, address: 13, and set data: 03, then press the
PAUSE button.
(The data will be automatically return to “00”.)
7)
When the IC1701 (D1) 
 IC1601 (U1) playback system is
normal, following data will be displayed in page: 4, address:
14 and 15.
8)
When the IC1701 (D1) 
 IC3501 (INDI) playback system is
normal, following data will be displayed in page: 4, address:
16 and 17.
9)
When the IC1701 (D1) 
 IC1901 (A1) playback system is
normal, following data will be displayed in page: 4, address:
18 and 19.
IC1901 (A1) Playback System Check
10) Select page: 4, address: 11, and set data: 10, then press the
PAUSE button.
11) Select page: 4, address: 11, and set data: 00, then press the
PAUSE button.
12) Select page: 4, address: 13, and set data: 04, then press the
PAUSE button.
(The data will be automatically return to “00”.)
13) When the IC1901 (A1) playback system is normal, following
data will be displayed in page: 4, address: 14 and 15.
14) Select page: 4, address: 11, and set data: 08, then press the
PAUSE button.
15) Select page: 4, address: 13, and set data: 07, then press the
PAUSE button.
(The data will be automatically return to “00”.)
16) Select page: 4, address: 11, and set data: 00, then press the
PAUSE button.
17) Perform “Recording System Check”.
Page
4
4
Address
15
14
Data
E5 (NTSC), 27 (PAL)
11 (NTSC), CA (PAL)
Page
4
4
Address
17
16
Data
C0 or BA (NTSC), DC (PAL)
6E or 04 (NTSC), 44 (PAL)
Page
4
4
Address
19
18
Data
33 or B2 (NTSC), A2 (PAL)
59 or 19 (NTSC), 03 (PAL)
Page
4
4
Address
15
14
Data
7B (NTSC), CC (PAL)
B5 (NTSC), C0 (PAL)
5-56
2. Recording System Check
Note:
Perform “Playback System Check” before this check.
1)
Playback the BIST check tape.
2)
Input the following data in order.
Note:
Press the PAUSE button each time set the data.
3)
While keep the HOLD switch of the adjustment remote
commander at ON (SERVICE) position, eject the BIST check
tape and insert a tape for recording in place of the tape.
4)
Select page: 0, address: 01, and set data: 01.
5)
Only for AEP and UK model, select page: D, address: 14, after
memorizing the data, set the bit value of bit 0 to “1”, and then
press the PAUSE button. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
6)
Select page: D, address: 15, after memorizing the data, set data:
07 and then press the PAUSE button.
7)
While keep the HOLD switch of the adjustment remote
commander at ON (SERVICE) position, set to the VTR
recording mode. (Use the wireless remote commander of 8mm
VCR, only for AEP and UK model.)
8)
Select page: 4, address: 11, and set data: 02, then press the
PAUSE button.
9)
Select page: 4, address: 13, and set data: 02, then press the
PAUSE button.
10) Select page: 4, address: 11, and set data: 00, then press the
PAUSE button.
IC1701 (D1) Recording System Check
11) Select page: 3, address: 01, and set data: 0D, then press the
PAUSE button.
12) Select page: 4, address: 1C, and set data: FF, then press the
PAUSE button.
13) Select page: 4, address: 11, and set data: 04, then press the
PAUSE button.
14) Select page: 4, address: 11, and set data: 00, then press the
PAUSE button.
15) Select page: 4, address: 13, and set data: 03, then press the
PAUSE button.
(The data will be automatically return to “00”.)
16) When the IC1601 (U1) 
 IC1701 (D1) recording system is
normal, following data will be displayed in page: 4, address:
14 and 15.
Page
4
4
4
4
4
4
4
4
4
4
4
4
Address
41
0F
0E
40
0F
40
40
0F
40
40
0F
40
Data
01
02
01
01
0A
00
01
0E
00
01
8E
00
Page
4
4
Address
15
14
Data
C6 (NTSC), F8 (PAL)
90 (NTSC), 3E (PAL)
17) When the IC1701 (D1) 
 IC3501 (INDI) recording system is
normal, following data will be displayed in page: 4, address:
16 and 17.
18) When the IC1901 (A1) 
 IC1701 (D1) recording system is
normal, following data will be displayed in page: 4, address:
18 and 19.
19) When the IC1701 (D1) 
 IC6101 (DX) recording system is
normal, following data will be displayed in page: 4, address:
1A and 1B.
20) Only for AEP and UK model, select page: D, address: 14, and
set the data memorized at step 5) .
21) Select page: D, address: 15, and set the data memorized at step
6).
22) Press the PAUSE button of the adjustment remote commander.
23) Select page: 0, address: 01, and set data: 00.
Page
4
4
Address
17
16
Data
19 (NTSC), 2A (PAL)
AA (NTSC), AE (PAL)
Page
4
4
Address
19
18
Data
76 (NTSC), CE (PAL)
B9 (NTSC), E7 (PAL)
Page
4
4
Address
1B
1A
Data
98 (NTSC), DC (PAL)
E6 (NTSC), 85 (PAL)
5-57
3-5.
IR TRANSMITTER ADJUSTMENTS
(Except DCR-TRV9E AEP/UK model)
Adjust using a IR receiver jig (J-6082-383-A).
Switch setting:
LASER LINK ................................................ ON (Red LED is lit)
1. IR Video Carrier Frequency Adjustment
  (MA-322 board)
Mode
Camera standby
Subject
Arbitrary
Measurement Point
Pin 5 of CN003 of IR receiver jig
(RF) (Or Pin !§ of IC8401)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
90
Specified Value
f = 11.85 ± 0.05 MHz
Connection of Equipment
Connect the measuring device as shown in the following figure,
and adjust.
Fig. 5-3-18
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 12, set data: 10, and press the PAUSE
button of the adjusting remote commander.
3)
Select page: D, address: 90, change the data, and set the video
carrier frequency (f) to the specified value.
4)
Press the PAUSE button of the adjusting remote commander.
5)
Select page: 2, address: 12, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6)
Select page: 0, address: 01, and set data: 00.
Main unit
IR receiver jig
CN003
pin 
5
Frequency counter
2. IR Video Deviation Adjustment (MA-322 board)
Mode
VTR playback
Signal
Alignment tape:
For audio operation check
(XH5-3 (NTSC))
(XH5-3P (PAL))
Measurement Point
VIDEO OUT terminal of IR receiver
jig (Terminated at 75 
)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
91
Specified Value
A = 1.00 ± 0.05 V
Connection of Equipment:
Connect the measuring device as shown in the following figure,
and adjust.
Fig. 5-3-19
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 91, and change the data, set the video
signal amplitude (A) to the specified value.
3)
Press the PAUSE button of the adjusting remote commander.
4)
Select page: 0, address: 01, and set data: 00.
For NTSC model
For PAL model
Fig. 5-3-20
Main unit
IR receiver jig
VIDEO 
OUT
75 
 
75 
 (1-247-804-11)
Oscilloscope
White (100%)
A
H
White (100%)
A
H
Page of 127