5-42
3-3.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Battery End Adjustment (VC-206 board)
Set the battery end voltage.
If the voltage is incorrect, the life of the battery will shorten. The
image at the battery end will also be rough.
Mode
Camera recording
Subject
Arbitrary
Measurement Point
LCD display of the adjustment remote
Measuring Instrument
commander
Adjustment Page
D
Adjustment Address
28 to 2C, 37
Note:
The lens block and cabinet (R) must be connected. Switch setting
1) AUTO FOCUS
OFF
2) LCD screen
Closed
3) NIGHT SHOT
OFF
Connection:
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-3-4.
Fig. 5-3-4
Adjusting method:
1)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.1 ± 0.1Vdc.
2)
Turn off the power supply.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Turn on the power supply.
5)
Load a cassette, and set to the camera recording mode.
6)
Select page: 0, address: 01, and set data: 01.
7)
Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 5.30 ± 0.01Vdc.
8)
Select page: 2, address: 51, read the data, and this data is named
Dref.
9)
Select page: D, address: 28, set data: Dref, and press the PAUSE
button of the adjustment remote commander.
10) Select page: D, address: 37, set data: Dref, and then press the
PAUSE button of the adjustment remote commander.
11) Convert Dref to decimal notation, and obtain Dref'. (Refer to
“Hexadecimal-decimal conversion table” of “Service mode”)
12) Calculate D
29
', D
2A
', D
2B
' and D
2C
' using following equations
(decimal calculation), convert it to a hexadecimal number, and
input each adjustment address.
Address: 29
D
29
' = Dref'+ 11
Address: 2A
D
2A
' = Dref'+ 36
Address: 2B
D
2B
' = Dref'+ 58
Address: 2C
D
2B
' = Dref'+ 66
Note:
After setting each data, be sure to press the PAUSE button.
13) Select page: 0, address: 01, and set data: 00.
Digital voltmeter
Regulated power supply
5.30 
±
 0.01 Vcd
3-4.
SERVO SYSTEM ADJUSTMENTS
1. T Reel FG Duty Adjustment (VC-206 Board)
Measurement Point
Adjustment remote commander
Measuring Instrument
display data
Adjustment Page
C
Adjustment Address
59, 6F
Specified Value
T reel FG Duty Adjustment:
The data of page: C, address: 6F is
“01”, or “02” , “03”.
Adjusting Method:
1)
Set the POWER switch to VTR (or PLAYER).
2)
Close the cassette compartment without inserting a cassette.
3)
Set the HOLD switch of the Adjustment remote commander to
ON (SERVICE position).
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: C, address: 6A, set data: 10, and press the PAUSE
button of the Adjustment remote commander.
6)
Select page: 3, address: 09, set data: 00, and press the PAUSE
button.
7)
Select page: 3, address: 01, set data: 1A, and press the PAUSE
button. (to start up automatic “T reel FG Duty Adjustments”.)
8)
Select page: 3, address: 02, and check that the data is changed
from “17” to “00”.
9)
Set the HOLD switch of the Adjustment remote commander to
OFF, and wait more than 2 seconds.
10) Set the HOLD switch to ON.
11) Check that the data of page: 3, address: 04 and that of page: C,
address: 6F are the same.
12) Select page: C, address: 6F. If the data is “01”, or “02”, “03”, it
means that the automatic T reel FG adjustment has ended
normally.
13) Select page: C, address: 6A, set data: 00, and press the PAUSE
button of the Adjustment remote commander.
14) Select page: 0, address: 01, and set data: 00.
15) Turn OFF the power supply.
2. Switching Position Adjustment (VC-206 Board)
Mode
VTR Playback
Signal
SW/OL reference tape (XH2-3)
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
4C, 4D, 4E, 4F
Specified Value
The data of page: 3, address: 03 is
“00”.
 Adjusting Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 0E, and press the PAUSE
button of the Adjustment remote commander.
3)
Select page: 3, address: 02, and check that the data is changed
from “0E“ to “00”.
4)
Select page: 3, address: 03, and check that the data is “00”.
5)
Set the HOLD switch of the Adjustment remote commander to
OFF, and wait more than 2 seconds (so that the adjustment
data is automatically written in page: C, address: 4C to 4F).
6)
Set the HOLD switch of the Adjustment remote commander to
ON.
7)
Select page: 0, address: 01, and set data: 00.
8)
Set to the stop mode.
9)
Turn OFF the power supply.
5-43
3-5.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the
specified value of “36 MHz Origin Oscillation Adjustment” of
“CAMERA SYSTEM ADJUSTMENT” is satisfied.
3-5-1.
RF Block Adjustments
1. Recording Current Adjustment (VC-206 Board)
Mode
VTR stop
Measurement Point
ODDch adjustment
CH1: Pin 5 of CN2701 (CL2718)
CH2: Pin 6 of CN2701 (CL2719)
EVENch adjustment
CH1: Pin 9 of CN2701 (CL2722)
CH2: Pin 8 of CN2701 (CL2721)
Measuring Instrument
Oscilloscope
ADD mode
CH2 INV mode
Adjustment Page
C
Adjustment Address
3E, 3F
Specified Value
A = 3.1 ± 0.1 Vp-p
Connection:
Disconnect CN2701 and connect as follows.
1)
ODDch adjustment: Connect a 180 
 resistor between Pin 5
of CN2701 (CL2718) and Pin 6 of CN2701 (CL2719).
2)
EVENch adjustment: Connect a 180 
 resistor between Pin
9 of CN2701 (CL2722) and Pin 8 of CN2701 (CL2721).
180 
Ω 
resistor (Parts code: 1-249-408-11)
Adjusting method:
1)
Equalize the vertical range of CH1 and CH2 of the oscilloscope.
2)
Set the oscilloscope to the ADD mode, and set CH2 to the INV
mode.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: 3, address: 01, set data: 0C, and press the PAUSE
button of the Adjustment remote commander.
5)
Select page: 3, address: 34, and set data: 01.
6)
Select page: C, address: 3F (ODDch adjustment) or address:
3E (EVENch adjustment), change the data and adjust the signal
voltage (A) to the specified value.
7)
Press the PAUSE button of the adjustment remote commander.
8)
Select page: 3, address: 34, and set data: 04.
9)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the Adjustment remote commander.
10) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-5
A
0.1 
µ
sec
2. PLL f
0
 Adjustment (VC-206 Board)
Mode
VTR stop
Measurement Point
Display data of page: 3, address: 04
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
3C, 3D
Specified Value
Displayed data is “FD” to “FF” or
“00” to “03”. (“FF”, “00” are center
values)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 05, and press the PAUSE
button of the Adjustment remote commander.
3)
Select page: 3, address: 36, and set data: 04.
4)
Select page: 3, address: 04, and check that the average value
D
04
 of the displayed data is “FD” to “FF” or “00” to  “03”. If
outside this range, change the data of page: C, address: 3C,
and check again.
[ If D
04
 is “80” to “FC” ]
Decrease the data of page: C, address: 3C. (As the data is to be
rewritten, press the PAUSE button of the adjusting remote
commander.)
[ If D
04
 is “04” to “7F” ]
Increase the data of page: C, address: 3C. (As the data is to be
rewritten, press the PAUSE button of the adjusting remote
commander.)
5)
Select page: 3, address: 36, and set data: 05.
6)
Select page: 3, address: 04, and check that the average value
D04 of the displayed data is “FD” to “FF” or “00” to  “03”. If
outside this range, change the data of page: C, address: 3D,
and check again.
[ If D
04
 is “80” to “FC” ]
Decrease the data of page: C, address: 3D. (As the data is to be
rewritten, press the PAUSE button of the adjusting remote
commander.)
[ If D
04
 is “04” to “7F” ]
Increase the data of page: C, address: 3D. (As the data is to be
rewritten, press the PAUSE button of the adjusting remote
commander.)
7)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the Adjustment remote commander.
8)
Select page: 3, address: 36, and set data: 02.
9)
Select page: 0, address: 01, and set data: 00.
5-44
3. CLK DELAY Adjustment (VC-206 Board)
Mode
Camera recording /playback
(LP mode)
Subject
Arbitrary
Signal
Playback signal of recorded tape
Measurement Point
CH1: CL9912 (Pin
203
 of IC1701)
     (C1ERP)
CH2: Pin 6 of CN9903 (JSWP)
Measuring Instrument
Oscilloscope
Trigger source: CH2
Adjustment Page
C
Adjustment Address
47
Adjusting method:
1)
Record for two minutes on any tape.
2)
Select page: 0, address: 01, and set data: 01.
3)
Write the following data in page: C, addresses: 40 to 44, 47,
4B, 5A.
(To write the data, press the PAUSE button of the adjusting
remote commander each time data is set.)
Page: C, address: 40, data: C0
Page: C, address: 41, data: C0
Page: C, address: 42, data: 90
Page: C, address: 43, data: 90
Page: C, address: 44, data: 90
Page: C, address: 47, data: C0
Page: C, address: 4B, data: 80
Page: C, address: 5A, data: 00
4)
Playback the recorded portion.
5)
Increase the data of page: C, address: 47 from “C0”, and read
the data D
1
 when the CH1 pulse is set to the whole audio and
video areas.
6)
Decrease the data of page: C, address: 47 from “C0”, and read
the data D
2
 when the CH1 pulse is set to the whole audio and
video areas.
7)
Obtain the average value of D
1
 and D
2
 , and take it as D
3
.
8)
Select page: C, address: 47, set data: D
3
, and press the PAUSE
button of the Adjustment remote commander.
9)
Select page: C, address: 4B, set data: 00, and press the PAUSE
button.
10) Select page: C, address: 5A, set data: 8C, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
12) After completing the adjusting, perform “5. AEQ Adjustment”.
Fig. 5-3-6
CH1
CH2
CH1
CH2
EVEN ch
EVEN ch
3.33msec
When the CH1 pulse is not set.
When the CH1 pulse is set.
4. AGC Center Level Adjustment (VC-206 Board)
Mode
Camera recording /playback
(LP mode)
Subject
Arbitrary
Signal
Playback signal of recorded tape
Measurement Point
CH1: CL9912 (Pin
203
 of IC1701)
     (C1ERP)
CH2: Pin 6 of CN9903 (JSWP)
Measuring Instrument
Oscilloscope
Trigger source: CH2
Adjustment Page
C
Adjustment Address
44
Adjusting method:
1)
Record for two minutes on any tape.
2)
Select page: 0, address: 01, and set data: 01.
3)
Write the following data in page: C, addresses: 40 to 44, 4B,
5A.
(To write the data, press the PAUSE button of the adjusting
remote commander each time data is set.)
Page: C, address: 40, data: C0
Page: C, address: 41, data: C0
Page: C, address: 42, data: 90
Page: C, address: 43, data: 90
Page: C, address: 44, data: 90
Page: C, address: 4B, data: 80
Page: C, address: 5A, data: 00
4)
Playback the recorded portion.
5)
Increase the data of page: C, address: 44 from “90”, and read
the data D
1
 when the CH1 pulse is set to the whole audio and
video areas.
6)
Decrease the data of page: C, address: 44 from “90”, and read
the data D
2
 when the CH1 pulse is set to the whole audio and
video areas.
7)
Obtain the average value of D
1
 and D
2
 , and take it as D
3
.
8)
Select page: C, address: 44, set data: D
3
, and press the PAUSE
button of the Adjustment remote commander.
9)
Select page: C, address: 4B, set data: 00, and press the PAUSE
button.
10) Select page: C, address: 5A, set data: 8C, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
12) After completing the adjusting, perform “5. AEQ Adjustment”.
Fig. 5-3-7
CH1
CH2
CH1
CH2
EVEN ch
EVEN ch
3.33msec
When the CH1 pulse is not set.
When the CH1 pulse is set.
5-45
5. AEQ Adjustment (VC-206 Board)
Mode
Camera recording /playback
(LP mode)
Subject
Arbitrary
Signal
Playback signal of recorded tape
Measurement Point
CH1: Pin 8 of CN9903
(RF MONITOR)
CH2: Pin 6 of CN9903 (JSWP)
Measuring Instrument
Oscilloscope
Trigger source: CH2
Adjustment Page
C
Adjustment Address
40, 41, 42, 43, 5A
Note:
Connect a 75 
Ω 
resister between Pin 8 (RF MONITOR) and Pin
4 (GND) of CN9903.
75 
Ω 
resister (Parts code: 1-247-804-11)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Write the following data in page: C, addresses: 40 to 43, 4B,
5A.
(To write the data, press the PAUSE button of the adjusting
remote commander each time data is set.)
Page: C, address: 40, data: C0
Page: C, address: 41, data: C0
Page: C, address: 42, data: 90
Page: C, address: 43, data: 90
Page: C, address: 4B, data: 80
Page: C, address: 5A, data: 00
3)
Record for two minutes from tape top.
4)
Rewind the tape, and play back from the tape top.
5)
When the RF output stabilizes, select page: 3, address: 01, set
data: 07, and press the PAUSE button of the adjusting remote
commander.
6)
About 20 to 30 seconds after pressing the PAUSE button, check
that the data of page: 3, address: 02 changes from “07” to “00”.
7)
Check that the data of page: 3, address: 03 is following value.
When “00” : Normal
When “01” : EVENch is faulty
When “02” : ODDch is faulty
When “03” : EVENch and ODDch are faulty
Perform the following procedure only when “00” is displayed.
8)
Read the data of page: 3, address: 04 to 07, and take the values
as D
04
, D
05
, D
06
 and D
07
.
9)
Select page: C, address: 40, set data: D
04
, and press the PAUSE
button of the Adjustment remote commander.
10) Select page: C, address: 42, set data: D
05
, and press the PAUSE
button.
11) Select page: C, address: 41, set data: D
06
, and press the PAUSE
button.
12) Select page: C, address: 43, set data: D
07
, and press the PAUSE
button.
13) Select page: C, address: 4B, set data: 00, and press the PAUSE
button.
14) Select page: C, address: 5A, set data: 8C, and press the PAUSE
button.
15) Select page: 0, address: 01, and set data: 00.
6. PLL Capture Range Adjustment (VC-206 Board)
Mode
Camera recording /playback
(LP mode)
Subject
Arbitrary
Signal
Playback signal of recorded tape
Measurement Point
CH1: CL9912 (Pin
203
 of IC1701)
     (C1ERP)
CH2: Pin 6 of CN9903 (JSWP)
Measuring Instrument
Oscilloscope
Trigger source: CH2
Adjustment Page
C
Adjustment Address
46
Adjusting method:
1)
Record for two minutes on any tape.
2)
Select page: 0, address: 01, and set data: 01.
3)
Write the following data in page: C, address: 4B and 5A.
(To write the data, press the PAUSE button of the adjusting
remote commander each time data is set.)
Page: C, address: 4B, data: 80
Page: C, address: 5A, data: 00
4)
Playback the recorded portion.
5)
Select page: C, address: 46, set data: 80, and press the PAUSE
button of the Adjustment remote commander.
6)
Set the data of page: C, address: 46 to “60”, and check that the
pulse is not set at the audio area head of the C1ERP waveform's
ODDch of the oscilloscope (CH1).
7)
Set the data of page: C, address: 46 to “A0”, and check that the
pulse is not set at the audio area head of the C1ERP waveform's
ODDch of the oscilloscope (CH1). After confirming steps 6)
and 7), set the data of page: C, address: 46 to “80”, and proceed
to step 12).
8)
If the pulse is set in steps 6) and 7), increase the data of page:
C, address: 46 from “80“, and read the data D
1
 when the pulse
is set at the audio area head of CH1.
9)
Decrease the data of page: C, address: 46 from “80“, and read
the data D
2
 when the pulse is set at the audio area head of CH1.
10) Obtain the average value of D
1
 and D
2
 , and take it as D
3
.
11) Select page: C, address: 46, set data: D
3
, and press the PAUSE
button of the Adjustment remote commander.
12) Select page: C, address: 4B, set data: 00, and press the PAUSE
button.
13) Select page: C, address: 5A, set data: 8C, and press the PAUSE
button.
14) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-8
CH1
CH2
CH1
CH2
ODD ch
3.33msec
Pulse is not set at the audio area head.
When the pulse is set at the audio area head.
Page of 127