5-13
7. G-CAM flip Adjustment
Set the color reproduction conditions to optimum.
Subject
Color bar chart standard picture frame
Measurement Point
Display data of page A of the
Measuring Instrument
adjustment remote commander (Note)
Adjustment Page
F
Adjustment Address
53
Note:
Displayed data of page A of the adjusting remote commander.
A : XX : XX
S2
S1
Adjusting method:
1)
Select page: 6, address: 00, and set data: 01.
2)
Select page: 6, address: 01, set data: 01, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 04, and set data: 16.
4)
Select page: F, address: 53, set data: 3F, and press the PAUSE
button of the adjustment remote commander.
5)
Select page A of the adjustment remote commander, and
compare the higher 2 digits (S1) and lower 2 digits (S2) of the
4-degits display data.
When S1 < S2
Perform steps 6) onwards.
When S1  S2
Perform steps “Processing after Completing Adjustments”.
6)
Select page: F, address: 53, set data: BF, and press the PAUSE
button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
Select page: 6, address: 04, and set data: 00.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 00, and set data: 00.
5-14
8. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart standard picture frame
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
2E, 30, 44, 45
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Switch setting:
1)
NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1)
Select page: 6, address: 00, and set data: 01.
2)
Select page: 6, address: 01, set data: 3D, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 16, set data: 37, and press the PAUSE
button of the adjustment remote commander.
4)
Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
5)
Change the data of page: F, address: 2E, 30, 44 and 45, and
settle each color luminance point in each color reproduction
frame.
Note:
Be sure to press the PAUSE button of the adjustment remote
commander before changing the addresses. If not, the new data
will not be written to the memory.
6)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2)
Select page: 6, address: 00, and set data: 00.
For NTSC model
For PAL mode
Fig. 5-1-9
Burst position
Burst position
5-15
9. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note)
Adjustment Page
F
Adjustment Address
2C
Specified Value
88 to 90 (NTSC)
88 to 90 (PAL)
Note:
The right two digits of the display data at the right bottom side of
the LCD and TV monitor is the object data.
CA 00 00XX
Object data
Switch setting:
1)
STEADY SHOT (Menu display) ..................................... OFF
2)
NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: 6, address: 00, and set data: 01.
4)
Select page: 6, address: 04, and set data: 01.
5)
Select page: 6, address: 40, and set data: 02.
6)
Select page: 6, address: 56, and set data: 40.
7)
Select page: 6, address: 01, set data: 19 and press the PAUSE
button of the adjustment remote commander.
8)
Select page: F, address: 2C, change the data and adjust the DDS
display data (Note) to the specified value.
9)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
Select page: D, address: 11, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 6, address: 00, and set data: 00.
4)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
5)
Select page: 6, address: 40, and set data: 00.
6)
Select page: 6, address: 56, and set data: 00.
10. Auto White Balance Standard Data Input
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
20 to 23, 3E, 3F
Note 1:
Perform “Color Reproduction Adjustment” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is 00. If not, turn the
power of the unit OFF/ON.
Switch setting:
1)
NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1)
Select page: 6, address: 00, and set data: 01.
2)
Wait for 2 seconds.
3)
Select page: 6, address: 01, and set data: 11, and press the
PAUSE button of the adjustment remote commander.
4)
Select page: 6, address: 01, and set data: 0D, and press the
PAUSE button of the adjustment remote commander.
(When the standard data is take in, the data will be automatically
input to page: F, address: 20 to 23, 3E, 3F.)
5)
Select page: 6, address: 02, and check that the data is “01”.
6)
Perform “Auto White Balance Adjustment”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2)
Select page: 6, address: 00, and set data: 00.
5-16
11. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
F
Adjustment Address
34, 35
Specified Value
R ratio: 2B40 to 2BC0
B ratio: 5E40 to 5EC0
Note 1:
Perform “Auto White Balance Standard Data Input” before this
adjustment.
Note 2:
The right four digits of the display data at the right bottom side of
the LCD and TV monitor is the object data.
CA 00 XXXX
Object data
Switch setting:
1)
NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1)
Place the C14 filter for color temperature correction on the
lens.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjustment remote commander.
4)
Select page: 6, address: 00, and set data: 01.
5)
Select page: 6, address: 01, and set data: 3F, and press the
PAUSE button of the adjustment remote commander.
6)
Select page: 6, address: 04, and set data: 04.
7)
Select page: F, address: 34, change the data and adjust the
average value of the DDS display data (Note 2) to the R ratio
specified value.
8)
Press the PAUSE button of the adjustment remote commander.
9)
Select page: 6, address: 04, and set data: 05.
10) Select page: F, address: 35, change the data and adjust the
average value of the DDS display data (Note 2) to the B ratio
specified value.
11) Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
Select page: D, address: 11, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 6, address: 00, and set data: 00.
4)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
5)
Select page: 6, address: 04, and set data: 00.
12. White Balance Check
Subject
Clear chart
(Color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.3
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-10. (A) to (C)
Switch setting:
1)
NIGHT SHOT switch ...................................................... OFF
Checking method:
1)
Check that the lens is not covered with either filter.
2)
Select page: 6, address: 01, set data: 0F, and press the PAUSE
button of the adjustment remote commander.
3)
Check that the center of the white luminance point is within
the circle shown Fig. 5-1-10 (A).
4)
Select page: 6, address: 01, set data: 23, and press the PAUSE
button of the adjustment remote commander.
5)
Place the C14 filter on the lens.
6)
Check that the center of the white luminance point settles in
the circle shown Fig. 5-1-10 (B).
7)
Remove the C14 filter, and place the ND filter 1.3 (1.0 + 0.3)
on the lens.
8)
Check that the white luminance point stopped moving, and then
remove the ND filter 1.3.
9)
Check that the center of the white luminance point settles within
the circle shown Fig. 5-1-10 (C).
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.