5-25
7. V-COM Level Adjustment (PD-98 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
VTR playback
Signal
Alignment tape:
For audio operation check
(XH5-3 (NTSC))
(XH5-3P (PAL))
Measurement Point
Pin 4 of CN5501 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
64
Specified Value
A = 4.95 ± 0.05V (NTSC)
A = 4.95 ± 0.05V (PAL)
Note:
Perform “Bright Adjustment” and “Contrast Adjustment” before this
adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 64, change the data and set the PANEL
COM signal level (A) to the specified value.
3)
Press the PAUSE button of the adjusting remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-20
A
2H
8. Color Adjustment (PD-98 board)
Set the color saturation to the standard value. If deviated, the color
will be to dark or light.
Mode
VTR playback
Signal
Alignment tape:
For audio operation check
(XH5-3 (NTSC))
(XH5-3P (PAL))
Measurement Point
Pin 2 of CN5501 (VG)
External trigger : Pin 4 of CN5501
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
6D
Specified Value
A = 0.15 ± 0.05V (NTSC)
A = 0.99 ± 0.05V (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 1F, set data: 02.
3)
Select page: D, address: 6D, change the data and set the voltage
(A) between the white and green to the specified value.
4)
Press the PAUSE button of the adjusting remote commander.
5)
Select page: 2, address: 1F, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
For NTSC model
For PAL model
Fig. 5-1-21
White (75
)
Green
A
2H
White (100
)
Green
2H
A
5-26
9. V-COM Adjustment (PD-98 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
66
Specified Value
The brightness difference between the
section A and section B is minimum.
Note:
Perform "Bright Adjustment" and “Contrast Adjustment” before this
adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 10, set data: 01, and press the PAUSE
button of the adjusting remote commander.
3)
Select page: 2, address: 1F, and set data: 01.
4)
Select page: D, address: 66, change the data so that the
brightness of the section A and that of the section B is equal.
5)
Press the PAUSE button of the adjusting remote commander.
6)
Select page: 2, address: 10, set data: 00, and press the PAUSE
button of the adjusting remote commander.
7)
Select page: 2, address: 1F, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-22
A
A
A
A
B
B
B
B
10. White Balance Adjustment (PD-98 board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
Camera E-E
Subject
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
60, 61
Specified Value
The LCD screen should not be
colored.
Note:
Check the white balance only when replacing the following parts. If
necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5502
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: D, address: 80 to 83.
Note:
 Press the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Select page: D, address: 60 and 61, and set the data to the initial
value.
Note:
 To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
4)
Check that the LCD screen is not colored. If colored, change
the data of page: D, address: 60 and 61 so that the LCD screen
is not colored.
Note:
 To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
5)
Input the following data to page: D, address: 82 and 83. Note:
Press the PAUSE button of the adjusting remote commander
each time to set the data.
6)
Select page: 0, address: 01, and set data: 00.
Address
Data
80
00
81
27
82
00
83
00
Address
Data
60
A0 (NTSC), A0 (PAL)
61
73 (NTSC), 73 (PAL)
Address
Data
80
38
81
00
82
20
83
20
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
ARRANGEMENT DIAGRAM FOR ADJUSTMENT PARTS
VC-206 board (SIDE A)
VC-206 board (SIDE B)
PD-98 board (SIDE A)
IC202
36
37
48
1 12
13
24
25
CL200
20
1
80
61
60
41
40
21
R1901
IC203
24 13
12
1
48
37
36
CL9912 20
2
1
19
(CPC)
25
19
CN5501
(CPC)
5-28
5-29
5-33
5-2. MECHANISM SECTION
ADJUSTMENT
For details of mechanism section adjustments, checks, and
replacement of mechanism parts, refer to the separate volume “DV
MECHANICAL ADJUSTMENT MANUAL 
  C Mechanism  ”.
2-1. OPERATING WITHOUT CASSETTE
1)
Refer to “2. Removal” and supply the power with the cabinet
assembly removed.
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Close the cassette compartment without the cassette.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: C, address: 52, and set data: FD, and press the
PAUSE button of the adjustment remote commander.
7)
Select page: D, address: 10, and set data: 10, and press the
PAUSE button of the adjustment remote commander.
8)
Turn off the HOLD switch of the adjustment remote
commander.
9)
Turn the power off and then on.
The above procedure enables the mechanism to operate without the
cassette. After checking operations be sure to perform “Procedure
After Checking Operations”. To use the “No-Cassette Operation
Mode” and “Forced Power ON Mode” together, set the following
data to page: D, address: 10.
Forced VTR power ON mode ............................................. 12
Forced Camera power ON mode ........................................ 11
[Procedure after checking operations]
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: C, address: 52, and set data: FF, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: D, address: 10, and set data: 00, and press the
PAUSE button.
4)
Select page: 0, address: 01, and set data: 00.
5)
Disconnect the power supply of the unit.
2-2. TAPE PATH ADJUSTMENT
1. Preparations for Adjustment
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Select page: 3, address: 3C, and set data: 07.
5)
Connect the oscilloscope.
Channel 1: VC-206 board, CN9903 Pin 8 (Note)
External trigger: VC-206 board, CN9903 Pin 6
(Connect the oscilloscope via CPC-8 jig (J-6082- 388-A)
6)
Playback an alignment tape (XH2-1) for tracking.
7)
Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, adjust according to the separate volume “DV
MECHANICAL ADJUSTMENT MANUAL   C Mechanism  ”.
8)
After completing the adjustment, perform “2. Procedure after
checking operations”.
Note:
Connect Pins 8 and 4 (GND) of CN9903 with a 75
 resistor.
CN9903 of VC-206 board
[Procedure after operations]
1)
Connect the adjustment remote commander, and turn on the
HOLD switch.
2)
Select page: 3, address: 3C, and set data: 00.
3)
Disconnect the power supply of the unit.
Fig. 5-2-1.
Pin No.
1
3
5
7
9
11
13
15
17
19
Signal Name
TCK
TDI
AFC ERR
IR FSC
VCC2
VCC1
LOCK
ENV OUT
TDO8
DEC B-Y
Pin No.
2
4
6
8
10
12
14
16
18
20
Signal Name
TMS
GND
JSWP
RF MONITOR
AGC IN
EQ IN
EVF BL 4.75V
EVF 4.75V (–)
VCO
EVF VG
CH1
CH2
(Trigger)
Must be flat
3.3msec
Page of 127