Sony DCR-TRV9 / DCR-TRV9E Service Manual ▷ View online
5-46
3-5-2.
Clock Adjustments
1. IC1900 27MHz XTAL f
0
Adjustment (VC-206 Board)
Set the sub-carrier frequency of the video output signal in the VTR
mode.
mode.
Mode
VTR stop
Signal
No signal
Measurement Point
R1901 (Pin 2 of IC1900)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
98
Specified Value
f = 13500000 ± 68 Hz (NTSC)
f = 13500000 ± 68 Hz (PAL)
f = 13500000 ± 68 Hz (PAL)
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 98, change the data and set the clock
frequency (f) to the specified value.
frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
2. IC1900 VCO Operation Check (VC-206 Board)
Mode
VTR stop
Signal
No signal
Measurement Point
Display data of page: 2, address: 0E
Measuring Instrument
Adjustment remote commander
Specified Value
“C0” to “FF”
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 05, set data: 02, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: D, address: B0, set data: 03, and press the PAUSE
button.
button.
4)
Select page: 2, address: 0E, and check that the data is “C0” to
“FF”.
“FF”.
5)
Select page: D, address: B0, set data: 05, and press the PAUSE
button.
button.
6)
Select page: 2, address: 0E, and check that the data is “C0” to
“FF”.
“FF”.
7)
Select page: D, address: B0, set data: 00, and press the PAUSE
button.
button.
8)
Select page: 2, address: 05, set data: 00, and press the PAUSE
button.
button.
9)
Select page: 0, address: 01, and set data: 00.
3. IC6101 41.85MHz VCO Operation Check
(VC-206 Board)
Mode
VTR playback
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 39
Measuring Instrument
Adjustment remote commander
Specified Value
“37” to “C9”
Checking method:
1)
1)
Select page: 3, address: 39, and check that the data is “37” to
“C9”.
“C9”.
5-47
3-5-3.
Base Band Block Adjustments
1. Composite Output Y Level Adjustment
(VC-206 Board)
Set the Y signal level of the composite video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Video signal terminal of AUDIO/
VIDEO jack (75
VIDEO jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
96
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
A = 300 ± 6 mV (PAL)
Note:
Insert a plug in the AUDIO/VIDEO jack.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 96, change the data and set the Y signal
level (A) to the specified value.
level (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: D, address: 15, and set the data memorized at step
2).
2).
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
8)
Perform “Composite Output Chroma Level Adjustment”.
Fig. 5-3-9
A
H
2. Composite Output Chroma Level Adjustment
(VC-206 Board)
Set the chroma signal level of the composite video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Video signal terminal of AUDIO/
VIDEO jack (75
VIDEO jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
97
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
A = 300 ± 6 mV (PAL)
Note 1:
Insert a plug in the AUDIO/VIDEO jack.
Note 2:
Perform “Composite Output Chroma Level Adjustment” before
this adjustment.
this adjustment.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 97, change the data and set the burst
signal level (A) to the specified value.
signal level (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: D, address: 15, and set the data memorized at step
2).
2).
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
8)
Perform “S-C Output Level Adjustment”.
Fig. 5-3-10
A
H
5-48
3. S-C Output Level Adjustment (VC-206 Board)
Set the chroma signal level of the S video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
jack (75
jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
94
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
A = 300 ± 6 mV (PAL)
Note 1:
Insert a plug in the S VIDEO jack.
Note 2:
Perform “Composite Output Y Level Adjustment” and “Composite
Output Chroma Level Adjustment” before this adjustment.
Output Chroma Level Adjustment” before this adjustment.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”)
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”)
3) Select page: D, address: 94, change the data and set the burst
signal level (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: D, address: 15, and set the data memorized at step
2).
2).
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-11
A
H
4. S-Y Output Level Adjustment (VC-206 Board)
Set the Y signal level of the S video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Y signal terminal of S VIDEO jack
(75
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
95
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
A = 300 ± 6 mV (PAL)
Note:
Insert a plug in the S VIDEO jack.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 95, change the data and set the sync
signal level (A) to the specified value.
signal level (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: D, address: 15, and set the data memorized at step
2).
2).
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-12
A
H
5-49
5. IC9004 AGC Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the AGC gain.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
Y signal terminal of S VIDEO jack
(75
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
9A
Specified Value
A = 1.00 ± 0.02V
Note 1:
Insert a plug in the S VIDEO jack.
Note 2:
Before perform this adjustment, check that the specified value of
“S-Y Output Level Adjustment” is satisfied.
“S-Y Output Level Adjustment” is satisfied.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 13, and set data: FE.
3)
Select page: D, address: 9A, change the data and set the Y
signal level (A) to the specified value.
signal level (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 2, address: 13, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
For NTSC model
For PAL model
Fig. 5-3-13
H
A
White (100%)
A
White (100%)
H
6. AFC TC Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the picture frame in recording.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
Y signal terminal of S VIDEO jack
(75
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A2
Specified Value
t
2
-t
1
= 0 ± 0.05
µ
sec
Note:
Insert a plug in the S VIDEO jack.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 13, and set data: FE.
3)
Check the delay time (t
1
).
4)
Select page: 2, address: 13, and set data: FF.
5)
Select page: D, address: A2, change the data so that the delay
time (t
time (t
2
) is equal to the delay time (t
1
) of step 3).
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 2, address: 13, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
For NTSC model
For PAL model
Fig. 5-3-14
H
t
1
or t
2
H
t
1
or t
2
Click on the first or last page to see other DCR-TRV9 / DCR-TRV9E service manuals if exist.