5-17
R-Y
2mm
B-Y
2mm
R-Y
B-Y
1.0mm
1.0mm
3mm
3mm
R-Y
B-Y
3mm
3mm
2.0mm
1.0mm
Fig. 5-1-10 (A)
Fig. 5-1-10 (B)
Fig. 5-1-10 (C)
13. Angular Velocity Sensor Sensitivity Adjustment
• This adjustment is performed only when replacing the angular
velocity sensor.
Although this adjustment need not be performed when the circuit
is damaged, etc., check the operations.
• Note down the sensitivity displayed on the angular velocity sensor
of the repair parts. At this time, note down also to which board it
was attached to.
Be sure to check because if attached incorrectly, the screen will
vibrate up and down or left and right during hand-shake correction
operations.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03JA or ENC03GA
Type B
ENC03JB or ENC03GB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, re-
adjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Adjustment Page
F
Adjustment Address
41, 42
Note:
The sensor sensitivity of SE451 and SE452 of  the CD-185 board is
written only on the repair parts.
Adjusting method:
1)
Select page: 6, address: 00, and set data: 01.
2)
Read the sensor sensitivity written on SE451 of the CD-185
board, and take this as S
451
.
3)
Read the sensor sensitivity written on SE452 of the CD-185
board, and take this as S
452
.
4)
Calculate D
43
' and D
44
' using the following equation (decimal
calculation).
NTSC model:
D
41
' = 85/S
452
D
42
' = 90/S
451
PAL model:
D
41
' = 118/S
452
D
42
' = 106/S
451
5)
Convert D
41
' and D
42
' into hexadecimal digits, to obtain D
41
and D
42
. (Round off decimal points)
6)
Select page: F, address: 41, set data: D
41
, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: F, address: 42, set data: D
42
, and press the PAUSE
button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
Select page: 6, address: 00, and set data: 00.
2)
Check that the steady shot operations have been performed
normally.
5-18
1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENT
Note 1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note 3:
Set the VF BRIGHT (Menu display) to the center.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN9903 of the VC-206 board. Connect the
Measuring Instruments via the CPC-8 jig (J- 6082-388-A).
The following table shows the Pin No. and signal name of CN9903.
Fig. 5-1-11
Pin No.
1
3
5
7
9
11
13
15
17
19
Signal Name
TCK
TDI
AFC ERR
IR FSC
VCC2
VCC1
LOCK
ENV OUT
TDO8
DEC B-Y
Pin No.
2
4
6
8
10
12
14
16
18
20
Signal Name
TMS
GND
JSWP
RF MONITOR
AGC IN
EQ IN
EVF BL 4.75V
EVF 4.75V (–)
VCO
EVF VG
CN9903 (CPC)
LI-64 board
Remove the cover
Note 1: Don’t disconnect the connector. If disconnect, data
such as, time, user-set menus will be lost.
Note 2: When removing cable from the LI-64 board, remove
the connector of the LI-64 board’s side.
1. EVF Initial Data Input
Mode
VTR stop
Signal
No signal
Adjustment Page
D
Adjustment Address
70 to 7B, 7E, 7F, 87 to 8F, 99
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, and input the data in the following table.
Note:
 To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
3)
Select page: 0, address: 01, and set data: 00.
Address
70
71
72
73
74
75
76
77
78
79
7A
7B
7E
7F
87
88
89
8A
8B
8C
8D
8E
8F
99
NTSC
5E
80
80
77
40
5E
90
B0
70
EA
82
9F
A7
A0
85
38
00
20
20
00
00
12
40
31
PAL
5E
80
80
77
40
5E
90
B0
70
EA
82
9F
A7
A0
E5
38
00
20
20
00
00
12
40
31
Data
Remark
Fixed value
White balance adjustment
White balance adjustment
Contrast adjustment
Fixed value
Fixed value
VCO adjustment
Backlight consumption current adjustment
Fixed value
Fixed value
Bright adjustment
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
5-19
2. VCO Adjustment (VF-121 board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin !• of CN9903 (VCO) on VC-206
board
Measuring Instrument
Oscilloscope (DC range)
Adjustment Page
D
Adjustment Address
76
Specified Value
A = 1.80 ± 0.05Vdc
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Check the GND level of the oscilloscope.
3)
Select page: D, address: 76, change the data and set the VCO
output voltage (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-12
H
A
GND level
(0Vdc)
3. Bright Adjustment (VF-121 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin @º of CN9903 (EVF VG) on
VC-206 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
7A
Specified Value
A = 7.1 ± 0.1V (NTSC)
A = 7.1 ± 0.1V (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 11, set data: 04, and press the PAUSE
button of the adjustment remote commander.
3)
Input the following data to page: D, address: 88 to 8D.
Note:
 Press the PAUSE button of the adjustment remote commander
each time to set the data.
4)
Select page: D, address: 7A, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Input the following data to page: D, address: 88 to 8D.
Note:
 Press the PAUSE button of the adjustment remote commander
each time to set the data.
7)
Select page: 2, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-13
Address
Data
88
00
89
00
8A
00
8B
00
8C
00
8D
00
Address
Data
88
38
89
00
8A
20
8B
20
8C
00
8D
00
A
2H
5-20
4. Contrast Adjustment (VF-121 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin @º of CN9903 (EVF VG) on
VC-206 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
73
Specified Value
A = 1.45 ± 0.1V (NTSC)
A = 1.35 ± 0.1V (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 11, set data: 04, and press the PAUSE
button of the adjustment remote commander.
3)
Input the following data to page: D, address: 88 to 8D.
Note:
 Press the PAUSE button of the adjustment remote commander
each time to set the data.
4)
Select page: D, address: 73, change the data and set the voltage
(A) between the white (30%) and pedestal to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Input the following data to page: D, address: 88 to 8D.
Note:
 Press the PAUSE button of the adjustment remote commander
each time to set the data.
7)
Select page: 2, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-14
Address
Data
88
00
89
27
8A
00
8B
00
8C
00
8D
00
Address
Data
88
38
89
00
8A
20
8B
20
8C
00
8D
00
2H
White (30%)
Pedestal
A
5. Backlight Consumption Current Adjustment
  (VF-121 board)
Set the backlight luminance and color temperature.
If deviated, the image may become dark or bright.
Mode
VTR stop
Signal
No signal
Measurement Point
+ Probe: Pin !¢ of CN9903
(EVF BL 4.75V) on VC-206 board
– Probe: Pin !§ of CN9903
(EVF BL 4.75V(–)) on VC-206 board
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
77
Specified Value
A = 21.0 ± 1.0mVdc
Note:
Adjust 30 seconds after running on the power supply. Adjusting
method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 77, change the data and set the voltage
difference (A) between Pin !¢ of CN9903 (EVF BL 4.75V)
and Pin !§ of CN9903 (EVF BL 4.75V(–)) to the specified
value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Page of 127