DOWNLOAD Sony DCR-TRV9 / DCR-TRV9E Service Manual ↓ Size: 34.67 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV9 DCR-TRV9E
Pages
127
Size
34.67 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M DCR-TRV9/TRV9E 98 US CAN E
File
dcr-trv9-dcr-trv9e.pdf
Date

Sony DCR-TRV9 / DCR-TRV9E Service Manual ▷ View online

5-38
3-2.
INITIALIZATION OF D, C PAGE DATA
1. Initializing the D Page Data
Note:
If the page D data is initialized, the following adjustments must be
performed again.
1) Modification of D page data
2) Clock adjustments of the video system adjustments
3) Base band block adjustments of the video system adjustments
4) Zoom Key Center Adjustment of the camera system adjustments
5) Color electronic viewfinder system adjustments
6) LCD system adjustments
7) IR transmitter adjustments
8) Battery end adjustment
Adjusting page
D
Adjusting Address
00 to FF
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 00, and set data: 2D, and press the
PAUSE button of the adjusting remote commander.
3)
Select page: 2, address: 01, set data: 2D, and press the PAUSE
button.
4)
Select page: 2, address: 02, and check that the data is “01”.
5)
Select page: 0, address: 01, and set data: 00.
6)
Perform “Modification of D Page Data”.
2. Modification of D Page Data
If the D Page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5)
After changing the data, select page: 0, address: 01, and set
data: 00.
3. D Page Table
Note:
Fixed data-1 : Initialized data. ( Refer to “1. Initializing the D Page
Data”.)
Fixed data-2 : Modified data. (Refer to “2. Modification of D Page
Data”).
Address
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
Initial value
NTSC
00
00
70
77
A0
AD
C0
70
PAL
00
00
70
77
A0
AD
C0
70
Remark
Test mode
Test mode
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Battery end adj.
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Battery end adj.
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1 (Initialized data)
5-39
Address
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
Initial value
NTSC
7D
A0
73
C7
70
59
B0
96
7A
6C
80
80
77
90
B0
PAL
7D
A0
73
C7
70
59
A0
96
7A
6C
80
80
77
90
B0
Remark
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Zoom key center adj.
Fixed data-2
Fixed data-1
White balance adj. (LCD)
Contrast adj. (LCD)
D range adj. (LCD)
V-COM level adj. (LCD)
VCO adj. (LCD)
V-COM adj. (LCD)
Fixed data-2
Fixed data-1
(Initialized data)
Bright adj. (LCD)
Color adj. (LCD)
Fixed data-1
Fixed data-2
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-2
VCO adj. (EVF)
Inverter current adj. (EVF)
Address
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
Initial value
NTSC
82
40
20
20
40
40
40
40
4C
2F
2A
32
1C
85
A3
69
69
92
PAL
82
40
20
20
40
40
40
40
4C
2F
2A
32
1C
85
A3
69
69
92
Remark
Fixed data-1
Fixed data-2
Bright adj. (EVF)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
IR video carrier adj.
IR video deviation adj.
IR audio deviation adj.
Fixed data-1
S-C output level adj.
S-Y output level adj.
Composite Y level adj.
Composite chroma level adj.
27MHz XTAL f0 adj.
Fixed data-1
AGC adj.
EVR Y  adj.
EVR CR adj.
EVR CB adj.
Decoder ACC adj.
Decoder APC adj.
Decoder hue adj.
AFC f
0
 adj.
AFC TC adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
5-40
Address
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4 to FF
Initial value
NTSC
FF
FF
FF
PAL
FF
FF
FF
Remark
Fixed data-1
(Initialized data)
Fixed data-2
CR clamp adj.
CB clamp adj.
Y clamp adj.
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
4. Initializing the C Page Data
Note:
If the page C data is initialized, the following adjustments must be
performed again.
1) Modification of C page data
2) All RF block adjustments of the video system adjustments
3) Servo system adjustments
Adjusting page
C
Adjusting Address
00 to 6F
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 4, address: 02, set data: 01, and press the PAUSE
button of the adjusting remote commander.
3)
Check that the data of page: 4, address: 02 changes in order of
“01”, “03”, “05”, “00”.
4) Select page: 0, address: 01, and set data: 00.
5) Perform “Modification of C Page Data”.
5. Modification of C Page Data
If the C Page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5)
After changing the data, select page: 0, address: 01, and set
data: 00.
6. C Page Table
Note:
Fixed data-1 : Initialized data. ( Refer to “4. Initializing the C Page
Data”.)
Fixed data-2 : Modified data. (Refer to “5. Modification of C PAGE
Data”).
Address
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
Initial value
NTSC
PAL
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-3-1
5-41
Address
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
Initial value
NTSC
00
00
00
00
00
00
00
00
00
00
00
00
F0
F0
70
70
C0
C0
90
90
90
80
C0
PAL
00
00
00
00
00
00
00
00
00
00
00
00
F0
F0
70
70
C0
C0
90
90
90
80
C0
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Emergency memory address
PLL f
0
 adj.
REC current adj.
AEQ adj.
AGC center level adj.
Fixed data-1
PLL capture range adj.
CLK DELAY adj.
Fixed data-1
Address
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
Initial value
NTSC
00
00
00
00
00
00
PAL
00
00
00
00
00
00
Remark
Fixed data-1
Switching position adj.
Fixed data-1
T reel FG duty adj.
Fixed data-2
Fixed data-1
T reel FG duty adj.
Table. 5-3-2
Page of 127
Display