Sony DCR-TRV9 / DCR-TRV9E Service Manual ▷ View online
5-50
7. AFC f
0
Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the free-run frequency of the AFC VCO.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
Pin 5 of CN9903 (AFC ERR) on
VC-206 board
VC-206 board
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
A1
Specified Value
A = 1.9 ± 0.1Vdc
Note:
Don't insert any plug in the S VIDEO jack.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: A1, change the data and set the AFC
error voltage (A) to the specified value.
error voltage (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
8. Decoder APC Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the free-run frequency of the decoder VXO.
Mode
VTR stop
Signal
No signal (Video signal terminal of
AUDIO/VIDEO jack) (Note 1)
AUDIO/VIDEO jack) (Note 1)
Measurement Point
Pin 3 of CN9903 (IR FSC) on VC-
206 board
206 board
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
9F
Specified Value
f = 3579545 ± 50 Hz (NTSC)
f = 4433619 ± 50 Hz (PAL)
f = 4433619 ± 50 Hz (PAL)
Note:
Insert a plug in the AUDIO/VIDEO jack.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 9F, change the data and set the IR
FSC frequency (f) to the specified value.
FSC frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
9. Decoder ACC Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the decoder ACC gain.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
Pin !ª of CN9903 (DEC B-Y) on
VC-206 board
VC-206 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
9E
Specified Value
A = 325 ± 20mV (NTSC)
A = 325 ± 20mV (PAL)
A = 325 ± 20mV (PAL)
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 9E, change the data and set the DEC
B-Y signal level (A) to the specified value.
B-Y signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-15
H
A
5-51
10. Decoder HUE Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the decoder hue.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
Pin !ª of CN9903 (DEC B-Y) on
VC-206 board
VC-206 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A0
Specified Value
A-B = 0 ± 10mV (NTSC)
A = Minimum amplitude (PAL)
A = Minimum amplitude (PAL)
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
NTSC model
Select page: D, address: A0, change the data so that the voltage
(A) between the yellow and cyan is equal to the voltage (B)
between the green and magenta.
(A) between the yellow and cyan is equal to the voltage (B)
between the green and magenta.
PAL model
Select page: D, address: A0, change the data so that the
waveform dose not appear double.
waveform dose not appear double.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
For NTSC model
For PAL model
Fig. 5-3-16
H
B
A
A
H
11. IC9004 Y clamp Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the clamp level of the Y AD OUT.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note)
Adjustment Page
D
Adjustment Address
B6
Specified Value
0F to 11
Note:
The two digits of the display data of the LCD and TV monitor is the
object data.
object data.
HI XX XXXX
Object data
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 40.
4)
Select page: 2, address: 97, and set data: 18.
5)
Select page: D, address: B6, change the data and adjust the
DDS display data (Note) to the specified value. (The data of
address: B6 should be “00“ to “99”.)
DDS display data (Note) to the specified value. (The data of
address: B6 should be “00“ to “99”.)
6)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
5-52
12. IC9004 CR clamp Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the clamp level of the CR AD OUT.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note)
Adjustment Page
D
Adjustment Address
B4
Specified Value
FF or 00 or 01
Note:
The two digits of the display data of the LCD and TV monitor is the
object data.
object data.
HI XX XXXX
Object data
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 40.
4)
Select page: 2, address: 97, and set data: 18.
5)
Select page: D, address: B4, set data: 4C, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
6)
Select page: D, address: B5, set data: 4C, and press the PAUSE
button.
button.
7)
Select page: D, address: B4, change the data and adjust the
DDS display data (Note) to the specified value. (The data of
address: B4 should be “00” to “99”.)
DDS display data (Note) to the specified value. (The data of
address: B4 should be “00” to “99”.)
8)
Press the PAUSE button of the adjustment remote commander.
9)
Perform “IC9004 CB clamp Adjustment”.
Processing after Completing Adjustments:
1)
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
13. IC9004 CB clamp Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the clamp level of the CB AD OUT.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
D
Adjustment Address
B5
Specified Value
FF or 00 or 01
Note 1:
The two digits of the display data of the LCD and TV monitor is
the object data.
the object data.
HI XX XXXX
Object data
Note 2:
Perform “IC9004 CR clamp Adjustment” before this adjustment.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 40.
4)
Select page: 2, address: 97, and set data: 18.
5)
Select page: D, address: B5, change the data and adjust the
DDS display data (Note 1) to the specified value. (The data of
address: B5 should be “00” to “99”.)
DDS display data (Note 1) to the specified value. (The data of
address: B5 should be “00” to “99”.)
6)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
5-53
14. IC9004 EVR Y Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the Y AD OUT level.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
D
Adjustment Address
9B
Specified Value
EA to EC (NTSC)
EA to EC (PAL)
EA to EC (PAL)
Note 1:
The two digits of the display data of the LCD and TV monitor is
the object data.
the object data.
HI XX XXXX
Object data
Note 2:
Use the 75% color bar signal shown in Fig. 5-3-17.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 70 (NTSC) or 40
(PAL).
(PAL).
4)
Select page: 2, address: 97, and set data: 50 (NTSC) or 30
(PAL).
(PAL).
5)
Select page: D, address: 9B, change the data and adjust the
DDS display data (Note 1) to the specified value.
DDS display data (Note 1) to the specified value.
6)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
For NTSC model
For PAL model
Fig. 5-3-17
(75%)
White
Y
e
llo
w
Cy
an
Green
Magenta
Red
Blue
Q
I
White
(100%)
Black
(100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
White
Blac
k
15. IC9004 EVR CR Adjustment (VI-148 Board)
(Except AEP/UK model)
Set the CR AD OUT level.
Mode
VTR stop
Signal
75% color bar (Video signal terminal
of AUDIO/VIDEO jack)
of AUDIO/VIDEO jack)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
D
Adjustment Address
9C
Specified Value
4D to 4F (NTSC)
53 to 55 (PAL)
53 to 55 (PAL)
Note 1:
The two digits of the display data of the LCD and TV monitor is
the object data.
the object data.
HI XX XXXX
Object data
Note 2:
Use the 75% color bar signal shown in Fig. 5-3-17.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 40.
4)
Select page: 2, address: 97, and set data: B0 (NTSC) or 9C
(PAL).
(PAL).
5)
Select page: D, address: 9C, change the data and adjust the
DDS display data (Note 1) to the specified value.
DDS display data (Note 1) to the specified value.
6)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
Click on the first or last page to see other DCR-TRV9 / DCR-TRV9E service manuals if exist.