Sony DCR-TRV9 / DCR-TRV9E Service Manual ▷ View online

5-9
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified value of “Composite Output Y Level Adjustment” and
“Composite Output Chroma Level Adjustment” of “Base band Block
Adjustment” of “VIDEO SYSTEM ADJUSTMENT” are satisfied.
1. 36 MHz Origin Oscillation Adjustment
  (VC-206 board)
Set the frequency of the clock for synchronization. If deviated, the
synchronization will be disrupted and the color will become
inconsistent.
Subject
Not required
Measurement Point
Pin !§ of IC203 (CL200)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
1C
Specified Value
f=18000000 ± 180Hz (NTSC)
f=18000000 ± 126Hz (PAL)
Adjusting method:
1)
Select page: 6, address: 00, and set data: 01.
2)
Select page: F, address: 1C, change the data and set the clock
frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 6, address: 00, and set data: 00.
2. Zoom Key Center Adjustment (VC-206 board)
Set the A/D value center of the microprocessor to the center voltage
of the zoom key.
If deviated, the zoom lens operates of itself ,even if the zoom key is
the center position.
Subject
Not required
Measurement Point
Display data of page: 2, address: 63
Measuring Instrument
of the adjustment remote commander
Adjustment Page
D
Adjustment Address
5B
Specified Value
The same data as page: 2, address: 63.
(The data should be “6D” to “93”.)
Note:
Perform this adjustment when the operation switch block (FK-4580)
is replaced.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 63, read the data, and this data is named
D
63
. (The data of address: 63 should be “6D“ to “93“.)
3)
Select page: D, address: 5B, set data: D
63
.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 0, address: 01, and set data: 00.
5-10
3. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Measurement Point
DDS display data of LCD or TV
Measuring Instrument
monitor (Note 3)
Adjustment Page
F
Adjustment Address
1E, 1F
Specified Value
80 to 82 during IRIS OPEN (Note 1)
13 to 17 during IRIS CLOSE (Note 2)
Note 1:
Select page: 6, address: 01, set data: 01, and press the PAUSE
button of the adjustment remote commander.
Note 2:
Select page: 6, address: 01, set data: 03, and press the PAUSE
button of the adjustment remote commander.
Note 3:
DDS display data of LCD or TV monitor.
CA 00 00XX
Object data
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 00, and set data: 01.
4)
Select page: 6, address: 04, and set data: 03.
5)
Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
6)
Select page: F, address: 1F, set data: 40, and press the PAUSE
button.
7)
Select page: F, address: 1E, set data: 40, and press the PAUSE
button.
8)
Read the DDS display data (the bottom two digits of the display
data at the bottom right of the LCD display or the TV monitor),
and this data is named K
2
.
9)
Select page: F, address: 1E, set data: 30, and press the PAUSE
button.
10) Read the DDS display data, and this data is named K
1
.
11) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
12) Read the DDS display data, and this data is named W
1
.
13) Select page: F, address: 1E, set data: 40, and press the PAUSE
button.
14) Read the DDS display data, and this data is named W
2
.
15) Convert W
1
, W
2
, K
1
, K
2
, to decimal notation, and obtain W
1
' ,
W
2
' , K
1
' , K
2
'. (Refer to “Hexadecimal-decimal Conversion
Table”. of “5-4. Service mode”.)
16) Calculate X
1
' using the following equations (decimal notation
calculation).
A'= W
2
' + K
1
' – W
1
' – K
2
' ....................................... Equation 1
B'= W1' – K1' ........................................................ Equation 2
X
1
'=[1728 + (48 
×
 A') – (16 
×
 B')]/A' ................... Equation 3
17) Convert X
1
' to hexadecimal notation, and obtain X
1
.
(Round off to one decimal place)
18) Select page: F, address: 1E, set data: X
1
, and press the PAUSE
button.
19) Select page: 6, address: 01, and set data: 03, and press the
PAUSE button.
20) Select page: F, address: 1F, change the data and adjust the DDS
display data to “15”.
21) Press the PAUSE button of the adjustment remote commander.
22) Select page: 6, address: 01, and set data: 01, and press the
PAUSE button.
23) Read the DDS display data, and this data is named W
0
. If W
0
lies within the “80” to “82” range, perform “Processing after
completing adjustments”. If it is lies outside the range, perform
the following adjustments.
24) Convert W
0
 to decimal notation, and obtain W
0
'.
25) Calculate X
2
' using the following equations (decimal notation
calculation).
C'= W
0
 – B'–23 ...................................................... Equation 4
X
2
'=[(108 – B') 
×
 (X
1
' – 48) + (48 
×
 C')]/C' .......... Equation 5
(X
1
' and B' are values obtained from equations 2) and 3) )
26) Convert X
2
' to hexadecimal notation, and obtain X
2
. (Round
off to one decimal place)
27) Select page: F, address: 1E, set data: X
2
, and press the PAUSE
button.
28) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
29) Select page: F, address: 1F, change the data and adjust the DDS
display data to “81”.
30) Press the PAUSE button of the adjustment remote commander.
31) Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
32) Check the DDS display data lies within the “13” to “17” range.
Processing after Completing Adjustments
1)
Select page: D, address: 11, and set data: 00, and press the
PAUSE button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
4)
Select page: 6, address: 04, and set data: 00.
5)
Select page: 6, address: 00, and set data: 00.
5-11
4. Flange Back Adjustment
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
4-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 230 ± 30 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
24 to 2B, 36 to 3D
Switch setting:
1)
NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
2)
Select page: 6, address: 00, and set data: 01.
3)
Check that the data of page: F, address: 24 to 2B, 36 to 3D is
the initial value (See table below).
4)
Select page: 6, address: 02, and check that the data is “00”.
5)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 6, address: 01, set data: 15, and press the PAUSE
button of the adjustment remote commander.
( The adjustment data will be automatically input to page: F,
addresses: 24 to 2B, 36 to 3D.)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Turn OFF the main power supply (8.4V).
2)
Perform “Flange Adjustment (2)”.
Address
24
25
26
27
28
29
2A
2B
Data
FB
1D
87
2A
79
13
00
00
Address
36
37
38
39
3A
3B
3C
3D
Data
00
00
46
00
19
00
21
02
4-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
24 to 2B, 36 to 3D
Switch setting:
1)
NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500 m away should
not be in the screen.)
2)
Select page: 6, address: 00, and set data: 01.
3)
Select page: 6, address: 02, and check that the data is “00”.
4)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
5)
Place a ND filter on the lens so that the optimum image is
obtain.
6)
Select page: 6, address: 01, set data: 29, and press the PAUSE
button of the adjustment remote commander.
(The adjustment data will be automatically input to page: F,
addresses: 24 to 2B, 36 to 3D.)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 00, and set data: 00.
2)
Turn OFF the main power supply (8.4V).
3)
Perform “Flange Back Check”.
5-12
5. Flange Back Check
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 230 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Note 1:
The front panel block must be assembled.
Switch setting:
1)
NIGHT SHOT switch ...................................................... OFF
2)
STEADY SHOT (Menu display) ..................................... OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Shoot the Siemens star with the zoom TELE end.
4)
Turn on the auto focus.
5)
Check that the lens is focused (Note 2).
6)
Select page: 6, address: 21, and set data: 10.
7)
Shoot the Siemens star with the zoom WIDE end.
8)
Observe the TV monitor and check that the lens is focused.
Note 2:
When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page A of the adjustment remote
commander.
1)
Select page: 6, address: 04, and set data: 0F.
2)
Page A shows the state of the focus.
A : 00 : XX
Odd: Focused
Even: Unfocused
Processing after Completing Adjustments:
1)
Select page: 6, address: 04, and set data: 00.
2)
Select page: 6, address: 21, and set data: 00.
6. Picture Frame Setting
Subject
Color bar chart standard picture frame
(1.5m from the front of the lens)
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, t=0 ± 0.1msec
Setting method:
1)
Adjust the zoom and the camera direction, and set to the
specified position.
2)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color bar chart standard picture frame”.
Check on the oscilloscope
1. Horizontal period
Fig. 5-1-6
2. Vertical period
Fig. 5-1-7
Color on the TV monitor
Fig. 5-1-8
A=B
C=D
A
B
C
D
t
±
 0.1msec
V
Color bar chart picture frame
TV monitor picture frame