DOWNLOAD Sony DCR-TRV240E / DCR-TRV340E (serv.man3) Service Manual ↓ Size: 12.61 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV240E DCR-TRV340E (serv.man3)
Pages
127
Size
12.61 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv240e-dcr-trv340e-sm3.pdf
Date

Sony DCR-TRV240E / DCR-TRV340E (serv.man3) Service Manual ▷ View online

— 5 —
DCR-TRV240E/TRV340E
3.
BLOCK DIAGRAMS
3-1.
OVERALL BLOCK DIAGRAM (1/5) ··························· 3-1
3-2.
OVERALL BLOCK DIAGRAM (2/5) ··························· 3-3
3-3.
OVERALL BLOCK DIAGRAM (3/5) ··························· 3-5
3-4.
OVERALL BLOCK DIAGRAM (4/5) ··························· 3-7
3-5.
OVERALL BLOCK DIAGRAM (5/5) (DCR-TRV240E) ··· 3-9
3-5.
OVERALL BLOCK DIAGRAM (5/5) (DCR-TRV340E) ···· 3-11
3-6.
POWER BLOCK DIAGRAM (1/3) ······························ 3-13
3-7.
POWER BLOCK DIAGRAM (2/3) ······························ 3-15
3-8.
POWER BLOCK DIAGRAM (3/3) ······························ 3-17
4.
PRINTED WIRING BOARDS AND
SCHEMATIC DIAGRAMS
4-1.
FRAME SCHEMATIC DIAGRAM (1/2) ······················· 4-1
FRAME SCHEMATIC DIAGRAM (2/2) ······················· 4-3
4-2.
PRINTED WIRING BOARDS AND
SCHEMATIC DIAGRAMS ············································ 4-5
• CD-357 (CCD IMAGER)
PRINTED WIRING BOARD AND
SCHEMATIC DIAGRAM ······························ 4-8
• LB-076 (EVF, BACK LIGHT)
PRINTED WIRING BOARD AND
SCHEMATIC DIAGRAM ······························ 4-9
• SI-032 (STEADY SHOT, LASER LINK)
PRINTED WIRING BOARD ······················· 4-11
• FP-411 FLEXIBLE BOARD ····································· 4-12
• SI-032 (STEADY SHOT, LASER LINK)
SCHEMATIC DIAGRAM ···························· 4-13
• PD-160 (CHA, DISPLAY DRIVE, BACK LIGHT, LCD
DRIVE, TG)
PRINTED WIRING BOARD ······················· 4-15
• FP-412 FLEXIBLE BOARD ····································· 4-18
• PD-160 (CHA, DISPLAY DRIVE, BACK LIGHT)(1/2)
SCHEMATIC DIAGRAM ···························· 4-19
• PD-160 (LCD DRIVE, TG)(2/2)
SCHEMATIC DIAGRAM ···························· 4-21
• CONTROL SWITCH BLOCK (CF-2500, FK-2500)
SCHEMATIC DIAGRAM ···························· 4-23
• LS-057 (S/T REEL SENSOR), FP-228 (DEW SENSOR),
FP-299 (MODE SWITCH), FP-300 (TAPE TOP),
FP-302 (TAPE END), FP-301 (TAPE LED)
FLEXIBLE BOARDS AND
SCHEMATIC DIAGRAMS ·························· 4-25
• CONTROL SWITCH BLOCK (SS-1380)
SCHEMATIC DIAGRAM ···························· 4-27
• FP-410 FLEXIBLE BOARD ····································· 4-28
Shematic diagram and printed wiring board of the
VC-276 board are not shown.
Pages from 4-29 to 4-82 are not shown.
4-3.
WAVEFORMS ······························································ 4-83
Waveforms and mounted parts location of the
VC-276 board are not shown.
Pages from 4-84 to 4-88 are not shown.
4-4.
MOUNTED PARTS LOCATION ································· 4-89
5.
ADJUSTMENTS
11.
Adjusting items when replacing main parts and boards. · 5-2
5-1.
CAMERA SECTION ADJUSTMENT ··························· 5-4
1-1.
PREPARATIONS BEFORE ADJUSTMENT
(CAMERA SECTION) ··················································· 5-4
1-1-1. List of Service Tools ························································ 5-4
1-1-2. Preparations ····································································· 5-5
1-1-3. Precaution ········································································ 5-7
1.
Setting the Switch ···························································· 5-7
2.
Order of Adjustments ······················································ 5-7
3.
Subjects ··········································································· 5-7
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 1B, 1C, 1F
PAGE DATA ···································································· 5-8
1-2-1. INITIALIZATION OF D PAGE DATA
(DCR-TRV240E) ····························································· 5-9
1.
Initializing the D Page Data ············································ 5-9
2.
Modification of D Page Data ··········································· 5-9
3.
D Page Table ···································································· 5-9
1-2-2. INITIALIZATION OF A, D PAGE DATA
(DCR-TRV340E) ··························································· 5-10
1.
Initializing the A, D Page Data ······································ 5-10
2.
Modification of A, D Page Data ···································· 5-10
3.
D Page Table ·································································· 5-10
4.
A Page Table ·································································· 5-10
1-2-3. INITIALIZATION OF B, 1B PAGE DATA
(DCR-TRV340E) ··························································· 5-11
1.
Initializing the B, 1B Page Data ···································· 5-11
2.
Modification of B, 1B Page Data ·································· 5-11
3.
Loader writing inhibit mode setting ······························ 5-11
4.
B Page Table ·································································· 5-11
5.
1B Page Table ································································ 5-11
1-2-4. INITIALIZATION OF 8, C, 1C PAGE DATA ·············· 5-12
1.
Initializing the 8, C, 1C Page Data ································ 5-12
2.
Modification of 8, C, 1C Page Data ······························ 5-12
3.
C Page Table ·································································· 5-12
4.
8 Page Table ··································································· 5-14
5.
1C Page Table ································································ 5-14
1-2-5. INITIALIZATION OF E, F, 1F PAGE DATA ··············· 5-16
1.
Initializing the E, F, 1F Page Data ································· 5-16
2.
Modification of E, F, 1F Page Data ······························· 5-16
3.
F Page Table ·································································· 5-16
4.
E Page Table ·································································· 5-17
5.
1F Page Table ································································ 5-18
1-3.
CAMERA SYSTEM ADJUSTMENTS ························ 5-19
1.
HALL Adjustment ························································· 5-19
2.
Flange Back Adjustment (Using Minipattern Box) ······· 5-20
3.
Flange Back Adjustment (Using Flange Back Adjustment
Chart and Subject More Than 500m Away) ·················· 5-21
3-1.
Flange Back Adjustment (1) ·········································· 5-21
3-2.
Flange Back Adjustment (2) ·········································· 5-21
4.
Flange Back Check ························································ 5-22
5.
Optical Axis Adjustment ··············································· 5-23
6.
Picture Frame Setting ···················································· 5-24
7.
Color Reproduction Adjustment ···································· 5-25
8.
Auto White Balance & LV Standard Data Input ··········· 5-25
9.
Auto White Balance Adjustment ··································· 5-26
10.
White Balance Check ···················································· 5-27
11.
Steady Shot Check ························································· 5-28
1-4.
ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT ····························································· 5-29
1.
VCO Adjustment (VC-276 board) ································ 5-29
2.
RGB AMP Adjustment (VC-276 board) ······················· 5-30
3.
Contrast Adjustment (VC-276 board) ··························· 5-30
1-5.
LCD SYSTEM ADJUSTMENT ··································· 5-31
1.
VCO Adjustment (PD-160 board) ································· 5-31
2.
PSIG Gray Adjustment (PD-160 board) ························ 5-32
3.
RGB AMP Adjustment (PD-160 board) ························ 5-32
4.
Black Limit Adjustment (PD-160 board) ······················ 5-33
5.
Contrast Adjustment (PD-160 board) ···························· 5-33
6.
Center Level Adjustment (PD-160 board) ····················· 5-34
7.
V-COM Adjustment (PD-160 board) ···························· 5-34
8.
White Balance Adjustment (PD-160 board) ·················· 5-35
5-2.
MECHANISM SECTION ADJUSTMENT ·················· 5-36
2-1.
Hi8/STANDARD 8 MODE ··········································· 5-36
— 6 —
DCR-TRV240E/TRV340E
2-1-1. OPERATING WITHOUT CASSETTE ························ 5-36
2-1-2. TAPE PATH ADJUSTMENT ········································ 5-36
1.
Preparations for Adjustment ·········································· 5-36
2-2.
DIGITAL8 MODE ························································ 5-37
2-2-1. HOW TO ENTER RECORD MODE WITHOUT
CASSETTE ··································································· 5-37
2-2-2. HOW TO ENTER PLAYBACK MODE WITHOUT
CASSETTE ··································································· 5-37
2-2-3. OVERALL TAPE PATH CHECK ································· 5-37
1.
Recording of the tape path check signal ························ 5-37
2.
Tape path check ····························································· 5-37
5-3.
VIDEO SECTION ADJUSTMENT ······························ 5-38
3-1.
PREPARATIONS BEFORE ADJUSTMENTS ············ 5-38
3-1-1. Equipment to Required ·················································· 5-38
3-1-2. Precautions on Adjusting ··············································· 5-39
3-1-3. Adjusting Connectors ···················································· 5-40
3-1-4. Connecting the Equipment ············································ 5-40
3-1-5. Alignment Tape ····························································· 5-41
3-1-6. Input/output Level and Impedance ································ 5-41
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENT ········ 5-42
1.
Initialization of 8, A, B, C, D, E, F, 1B, 1C, 1F
Page Data ······································································· 5-42
2.
Serial No. Input ····························································· 5-42
2-1.
Company ID Input ························································· 5-42
2-2.
Serial No. Input ····························································· 5-42
3-3.
SERVO AND RF SYSTEM ADJUSTMENT ··············· 5-44
1.
REEL FG Adjustment (VC-276 board) ························· 5-44
2.
PLL f
0
 & LPF f
0
 Adjustment (VC-276 board) ·············· 5-44
3.
Switching Position Adjustment (VC-276 board) ··········· 5-45
4.
AGC Center Level and APC & AEQ Adjustment ········· 5-45
4-1.
Preparations before adjustments ···································· 5-45
4-2.
AGC Center Level Adjustment (VC-276 board) ··········· 5-45
4-3.
APC & AEQ Adjustment (VC-276 board) ···················· 5-46
4-4.
Processing after Completing Adjustments ···················· 5-46
5.
PLL f
0
 & LPF f
0
 Fine Adjustment (VC-276 board) ······ 5-47
6.
Hi8/Standard8 Switching Position Adjustment
(VC-276 board) ····························································· 5-47
7.
CAP FG Duty Adjustment (VC-276 board) ·················· 5-48
3-4.
VIDEO SYSTEM ADJUSTMENTS ····························· 5-49
1.
36MHz Origin Oscillation Adjustment (VC-276 board) · 5-49
2.
S VIDEO OUT Y Level Adjustment (VC-276 board) ··· 5-49
3.
S VIDEO OUT Chroma Level Adjustment
(VC-276 board) ····························································· 5-50
4.
VIDEO OUT Y, Chroma Level Check (VC-276 board) ·· 5-50
5.
Hi8/Standard8 Y/C Output Level Setting
(VC-276 board) ····························································· 5-51
6.
Hi8/standard 8mm AFC f
0
 Adjustment
(VC-276 board) ····························································· 5-51
3-5.
AUDIO SYSTEM ADJUSTMENTS ···························· 5-52
1.
Hi8/Standard8 AFM BPF f
0
 Adjustment
(VC-276 board) ····························································· 5-52
2.
Hi8/Standard8 AFM 1.5 MHz Deviation Adjustment
(VC-276 board) ····························································· 5-53
3.
Hi8/Standard8 AFM 1.7 MHz Deviation Adjustment
(VC-276 board) ····························································· 5-53
4.
Digital8 Playback Level Check ····································· 5-53
5.
Overall Level Characteristics Check ····························· 5-53
6.
Overall Distortion Check ··············································· 5-53
7.
Overall Noise Level Check ············································ 5-54
8.
Overall Separation Check ·············································· 5-54
5-4.
SERVICE MODE ·························································· 5-55
4-1.
ADJUSTMENT REMOTE COMMANDER ················ 5-55
1.
Using the Adjustment Remote Commander ·················· 5-55
2.
Precautions Upon Using  the Adjustment Remote
Commander ··································································· 5-55
4-2.
DATA PROCESS ··························································· 5-56
4-3.
SERVICE MODE ·························································· 5-57
1.
Setting the Test Mode ···················································· 5-57
2.
Emergence Memory Address ········································ 5-57
2-1.
EMG Code (Emergency Code) ····································· 5-57
2-2.
MSW Code ···································································· 5-58
3.
Bit Value Discrimination ··············································· 5-59
4.
Switch check (1) ···························································· 5-59
5.
Switch check (2) ···························································· 5-60
6.
Switch check (3) ···························································· 5-60
7.
Switch check (4) ···························································· 5-61
8.
Record of Use check (1) ················································ 5-62
9.
Record of Use check (2) ················································ 5-62
10.
Record of Self-diagnosis check ····································· 5-63
6.
REPAIR PARTS LIST
6-1.
EXPLODED VIEWS ······················································ 6-1
6-1-1. OVERALL SECTION ····················································· 6-1
6-1-2. CABINET (L) SECTION-1 ············································ 6-2
6-1-3. CABINET (L) SECTION-2 ············································ 6-3
6-1-4. LENS, EVF SECTION ···················································· 6-4
6-1-5. CABINET (R) SECTION ··············································· 6-5
6-1-6. LCD SECTION ······························································· 6-6
6-1-7. CASSETTE COMPARTMENT ASSY, DRUM ASSY ··· 6-7
6-1-8. LS CHASSIS BLOCK ASSEMBLY ······························· 6-8
6-1-9. MECHANICAL CHASSIS BLOCK ASSEMBLY-1 ······ 6-9
6-1-10. MECHANICAL CHASSIS BLOCK ASSEMBLY-2 ·· 6-10
6-2.
ELECTRICAL PARTS LIST ········································ 6-11
Parts list of the VC-276 board are not shown.
Pages from 6-14 to 6-25 are not shown.
 *  Optical axis frame and Color reproduction frame are
shown on pages 220 and 221.
— 7 —
DCR-TRV240E/TRV340E
SERVICE NOTE
1.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied (8.4V) to the battery terminal using the service power code (J-6082-223-A), the power
is shut off so that the unit cannot operate.
These following two methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Use the DC IN terminal. (Use the AC power adaptor.)
Method 2.
Connect the adjustment remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the HOLD switch to the “ADJ” side.
2.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
1
Refer to 2-2. to remove the front panel section.
2
Refer to 2-3. to remove the cabinet (upper) section.
3
Refer to 2-3. to remove the cabinet (R) section.
4
Refer to 2-4. to remove the lens section.
5
Refer to 2-5. to remove the EVF section.
6
Refer to 2-6. to remove the battery panel section.
7
Refer to 2-8. and 2-9. to remove the cabinet (L) section. (Include the CS frame assembly and control switch block (SS-1380).)
8
Disconnect CN4401 (2P) of VC-276 board.
9
Add +5V from the DC POWER SUPPLY and unload with a pressing the cassette compertment.
qa
 
Let your hold the cassette 
     compartment and rise the cassette
     compartment to take out a cassette.
DC power supply
(+5V)
Loading 
motor
Adjust the bending 
of a tape
Timing belt
Press the cassette compartment not 
to rise the cassette compartment
Disconnect CN4401 of 
VC-276 board
0
Pull the timing belt in the direction of 
arrow 
A
 with a pincette while pressing 
the cassette compartment (take care 
not to damage) to adjust the bending 
of a tape.
Pincette
Timing belt
A
— 8 —
DCR-TRV240E/TRV340E
SELF-DIAGNOSIS FUNCTION
1.
Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder or Display
window what to do. This function consists of two display; self-
diagnosis display and service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
Note: The “self-diagnosis display” data will be backed up by the coin-type lithium battery (CF-2500 block BT101). When the
CF-2500 block is disconnected, the “self-diagnosis display” data will be lost by initialization.
2.
Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
viewfinder or Display window shows a 4-digit display consisting
of an alphabet and numbers, which blinks at 3.2 Hz. This 5-character
display indicates the “repaired by:”, “block” in which the problem
occurred, and “detailed code” of the problem.
3.
Service Mode Display
The service mode display shows up to six self-diagnosis codes shown in the past.
3-1.
Display Method
While pressing the “STOP” key, set the switch from OFF to “VTR or PLAYER”, and continue pressing the “STOP” key for 5 seconds
continuously. The service mode will be displayed, and the counter will show the backup No. and the 5-character self-diagnosis codes.
3-2.
Switching of Backup No.
By rotating the control dial, past self-diagnosis codes will be shown in order. The backup No. in the [] indicates the order in which the
problem occurred. (If the number of problems which occurred is less than 6, only the number of problems which occurred will be shown.)
[1] : Occurred first time
[4] : Occurred fourth time
[2] : Occurred second time
[5] : Occurred fifth time
[3] : Occurred third time
[6] : Occurred the last time
3-3.
End of Display
Turning OFF the power supply will end the service mode display.
Order of previous errors
Backup No.
Self-diagnosis Codes
C : 3 1 : 1 1
[3]
Lights up
Viewfinder
[3] C : 3 1 : 1 1
3 C : 3 1 : 11
Display window
1 1
3 1
C : 3 1 : 11
C
Repaired by:
Refer to page 9 and 10.
Self-diagnosis Code Table.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder
Display window
C : 3 1 : 1 1
Display window
Control dial
Page of 127
Display