DOWNLOAD Sony DCR-TRV240E / DCR-TRV340E (serv.man3) Service Manual ↓ Size: 12.61 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV240E DCR-TRV340E (serv.man3)
Pages
127
Size
12.61 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv240e-dcr-trv340e-sm3.pdf
Date

Sony DCR-TRV240E / DCR-TRV340E (serv.man3) Service Manual ▷ View online

5-12
DCR-TRV240E/TRV340E
1-2-4.
INITIALIZATION OF 8, C, 1C PAGE DATA
Note: When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 1C Page Data
Note1: If “Initializing the 8, C, 1C Page Data” is performed, all
data of the 8 page, C page and 1C page will be initialized.
(It is impossible to initialize a single page.)
Note2: If the 8, C, 1C page data has been initialized, following adjustments
need to be performed again.
1) Modification of 8, C, 1C page data
2) Serial No. input
3) Viewfinder system adjustments
4) LCD system adjustments
5) Servo and RF system adjustments
6) Video system adjustments
7) Audio system adjustments
Note3: The power supply voltage must be 6.1 ± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to A3
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
10
Set the data.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
2
00
29
Set the data
7
2
01
29
Set the data, and press the PAUSE
button.
8
Perform “Modification of 8, C, 1C
Page Data”.
2. Modification of 8, C, 1C Page Data
If the 8, C, 1C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1C page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1C page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. C Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”.)
00 to 0F
10
11
12
13
14 to 15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
EE
00
00
00
E0
E0
20
20
25
25
25
3E
3E
CA
99
88
Switching position adj.
Fixed data-1
Hi8/std8 CAP FG duty adj.
Reel FG adj.
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
Address
Remark
Initial value
5-13
DCR-TRV240E/TRV340E
*1: DCR-TRV240E/DCR-TRV340E
Table. 5-1-7.
26
27
28
29
2A to 2B
2C
2D
2E
2F
30 to 3B
3C
3D to 3E
3F
40
41
42
43
44
45
46 to 47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55 to 57
58
59
5A
5B to 5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F to 71
72
73 to 75
76
77 to 79
7A
7B to 81
82
83 to 85
86
87 to 88
89
8A
8B to AB
AC
AD to AE
AF
B0 to E1
E2
E3
E4 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
E3
A1
20
03
E0
0A
00
50
69
64
A6
94
80
69
56
9C
26
5C/68
70/59
21/22
9D/A1
08
3D/3F
7E/81
6C/6F
20/1E
37
00
00
00
00
00
00
00
00
00
00
00
00
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-2
LPF fo adj.
Fixed data-1
APC adj.
Fixed data-1
Fixed data-2
Reel FG adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Hi8/std8 switching position adj.
Fixed data-1
Hi8/std8 AFC fo adj.
Hi8/Std8 Y/C output level set
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Hi8/std8 AFM 1.5MHz deviation adj.
Hi8/std8 AFM 1.7MHz deviation adj.
Hi8/std8 AFM BPF fo adj.
Fixed data-2
VCO adj. (EVF)
Fixed data-1
RGB AMP adj. (EVF)
Fixed data-1
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
VCO adj. (LCD) *1
V-COM adj. (LCD) *1
RGB AMP adj. (LCD) *1
Black limit adj. (LCD)
PSIG gray adj. (LCD) *1
White balance adj. (LCD) *1
Contrast adj. (LCD) *1
Center level adj. (LCD)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Emergency memory address
Address
Remark
Initial value
Address
Remark
Initial value
C page
5-14
DCR-TRV240E/TRV340E
4. 8 Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”.)
Table. 5-1-8.
5. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”.)
00 to 18
19
1A to 34
35
36 to 49
4A
4B to 51
52
53 to 79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85 to 89
8A
8B
8C
8D
8E
8F
90
91
92
93
94 to A3
08
00
46
01
02
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Address
Remark
Initial value
00 to 03
04
05 to 06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12 to 13
14
15
16 to 17
18
19 to 1A
1B
1C
1D
1E
1F
20 to 22
23
24 to 26
27
28 to 39
3A
3B
3C
3D
3E
3F to 40
41
42 to 43
44
45
46
47
48
49
4A
4B to 4F
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
5-15
DCR-TRV240E/TRV340E
Table. 5-1-9.
50
51 to 55
56
57
58 to 5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B to 6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83 to 85
86
87
88
89
8A
8B
8C to 97
98
99 to 9E
9F
A0 to FF
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
1C page
Page of 127
Display

Sony DCR-TRV240E / DCR-TRV340E (serv.man3) Service Manual ▷ Download