Sharp MX-M364N / MX-565N (serv.man5) Service Manual ▷ View online
MX-M565N MX-PNX6A/B/C/D 14 – 5
3) Secure the main unit and the punch unit with the fixing screw
(Packed items of the MX-FN11).
4) Close the front door of punch unit.
5) Install the fixing screw (Packed items of MX-FN11) on rear
side.
6) Install the rear cover of punch unit with the fixing screws.
7)
By using nippers, split the removed connector cover of the fin-
isher along the perforated line.
isher along the perforated line.
8)
Install the connector cover of the finisher and fix it with the fix-
ing screw.
ing screw.
G. Connection of connector to the main unit
1)
Connect two connectors of the finisher to the main unit, and
tighten the screws.
tighten the screws.
MX-M565N MX-PNX6A/B/C/D 14 – 6
H. Punch position label attachment
1) Attach the punch position label (Packed items of the MX-FN11)
to the position indicated in the figure.
For scanner
For scanner
For DSPF/RSPF
I. Turn on the power of the main unit
1) Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
power switch.
DSPF
RSPF
R2.5 connection line
Edge line R 2.5
CAUTION
Cleaning of the document scan section
When streaks appear on copy or scan
images, open the automatic document
feed unit and clean the document scan
section with the glass cleaner (accessory).
images, open the automatic document
feed unit and clean the document scan
section with the glass cleaner (accessory).
Document scan section
MX-M565N MX-TR13N 15 – 1
MX-M565N
Service Manual
[15] MX-TR13N
1. Unpacking
A. Packed items check
2. Installation
Before installation, be sure to turn both the operation and main
power switches off and disconnect the power plug from the power
outlet. Make double sure that the data lamp on the operation panel
does not light up or blink when performing installation.
power switches off and disconnect the power plug from the power
outlet. Make double sure that the data lamp on the operation panel
does not light up or blink when performing installation.
A. Right paper exit unit attachment
1)
Remove the right paper exit cover from the right paper exit unit
and remove the mylar of both side.
and remove the mylar of both side.
2)
Remove the cover.
3)
Remove the paper guide.
4)
Attach the right paper exit unit, and fix it with the screw.
Connect the connector.
Connect the connector.
5)
Remove the Upper transport fulcrum holder and one E ring.
* Dispose the removed Upper transport fulcrum holder and
E ring.
* Dispose the removed Upper transport fulcrum holder and
E ring.
No.
Name
Quantity
1
Paper exit tray
1
2
Right paper exit unit
1
3
Full detection actuator
1
4
E ring (E4)
1
5
Bearing
1
6
Fixing screw(M3x6 S-tight)
2
7
Solenoid unit
1
1
2
3
4
5
6
7
2
1
Reverse
Mylar
1
2
1
1
1
1
1
2
1
1
1
2
2
1
2
2
1
2
MX-M565N MX-TR13N 15 – 2
6) Fix the E ring and the Bearing to the Shaft.
7) Fix the Solenoid unit with the screws (M3x6 S-Tight).
* Check whether the Arm of the Solenoid unit is fxed to the
hole of the ADU frame F and the ADU base plate.
hole of the ADU frame F and the ADU base plate.
8) Connec the connector of the Right arm unit to the connector of
the Solenoid unit.
9)
Attach the right paper exit cover, and fix it with the screw.
Connect the connector.
Connect the connector.
B. Paper exit tray attachment
1)
Attach the paper exit tray and the full-detection actuator
included in the package.
included in the package.
Be careful of the installing direction of the full detection actua-
tor.
tor.
C. Turn ON the power of the main unit
1)
Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
and turn ON the main power switch and the operation panel
power switch.
D. Tray setting
Use SIM26-1 to set the tray YES/NO.
1
2
2
1
Pass the lead line
into the M clamp.
into the M clamp.
2
2
2
2
2
1
1
2