MX-M565N  MX-PNX6A/B/C/D  14 – 1
MX-M565N
Service Manual
 
[14] MX-PNX6A/B/C/D
1. Unpacking
A. Pulling out of the punch unit
B. Removal of the protection material
1) Remove the fixing tape and protection material.
2)
Open the front cover, and open the top cover.
3)
Remove the screws, and remove the fixing material. (2 posi-
tions)
4)
Close the top cover, and close the front cover.
1
2
1
2
MX-M565N  MX-PNX6A/B/C/D  14 – 2
C. Packed items check
2. Installation
NOTE: Before installation, be sure to turn both the operation and
main power switches off and disconnect the power plug
from the power outlet. Make double sure that the data lamp
on the operation panel does not light up or blink when per-
forming installation.
NOTE: Before installing the punch unit, unpack the finisher.
A. Installation of punch unit
1) Attach the step screw A (Packed items) to the finisher.
2)
Remove the fixing screw, and remove the connector cover on
rear side of the finisher.
3)
Hang the punch unit on the step screws installed to the fin-
isher.
4)
Tighten the step screws bundled to the punch unit, fix the
punch unit.
No.
Name
Quantity
1
P tight M4x12
1
2
Step screw A
2
3
Cap screw M3x6
3
4
Binding head M4x12
4
5
Front cover
1
6
Front cover mounting fixture
1
7
Connection fixture F (for punch)
1
8
Connection fixture R (for punch)
1
9
Guide mylar upper (Not used)
1
10
Guide mylar lower (Not used)
1
1
2
3
5
6
7
8
9
10
P
P
4
1
2
MX-M565N  MX-PNX6A/B/C/D  14 – 3
5) Attach the front cover mounting fixture (Packed items) with the
fixing screws (Packed items).
Remove the screw of the finisher, and reuse it. Install it using
the reuse screw, and three fixing screws (Packed items) bun-
dled to punch unit.
6) Open the front door of punch unit.
7) Engage the pawls of the rear side of front cover (Packed
items), attach the front cover with the fixing screw (Packed
items).
B. Connection of connector of the finisher and 
punch unit
1)
Remove the fixing screws, and remove the rear cover.
2)
Connect two connectors of the finisher to the PWB of punch
unit, and fix the harness to the clamp.
C. Install of the Connection fixture F/R
1)
Install the Connection fixture F (Packed items) to the main unit
with the fixing screws (Packed items).
2)
Install the Connection fixture R (Packed items) to the main unit
with the fixing screws (Packed items).
2
3
1
MX-M565N  MX-PNX6A/B/C/D  14 – 4
D. Check of the connected position of main unit 
and finisher
1) Engage the finisher that has installed punch unit to the main
unit, and temporarily fix.
* Insert the rail of the finisher unit into the rail reception fixture
of main unit, fix temporarily.
2) Open the front door of punch unit.
3) Check that the center of the screw hole of the punch unit is in
the range of specification of an oval hole of the mounting fix-
ture  in front side of main unit.
* When not the range of specification, progress to the proce-
dure of "F. Adjustment".
If the adjustment is not required, remove the screw from the
screw hole directly and push the caster into it until the instal-
lation fixing. (MX-FN11 only)
E. Adjustment
* Refer to the adjustment procedure of each finisher.
F. Install to main unit
1)
Engage the finisher that has installed punch unit to the main
unit.
2)
Open the front door of punch unit.
Page of 127