DOWNLOAD Sharp MX-M364N / MX-565N (serv.man5) Service Manual ↓ Size: 45.47 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M364N MX-565N (serv.man5)
Pages
127
Size
45.47 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Installation Manual (Revised January2016).
File
mx-m364n-mx-565n-sm5.pdf
Date

Sharp MX-M364N / MX-565N (serv.man5) Service Manual ▷ View online

MX-M565N  MX-FWX1  23 – 1
MX-M565N
Service Manual
 
[23] MX-FWX1
1.  Unpacking
A. Packed items check
2.  Installation
In order to specify the address of the Internet Fax with the PC-FAX
driver, the PC-FAX driver must be updated by the Internet Fax
expansion kit.
A. Enable setting of functions
1) Enter the product key to enable the functions.
a)
Enter the system setting mode.
b)
The machine enters the product key input mode.
c)
Enter the product key.
d)
Press the registration key.
2) After completion of the product key input, turn OFF the power
switch on the operation panel of the machine, and turn OFF
the main power switch.
3) Turn ON the main power switch and the power switch on the
operation panel.
B. Confirmation of function enable
Execute SIM22-10 (Machine configuration display) to check to con-
firm that the set functions are enable.
No.
Name
Quantity
1
CD-ROM
1
2
Product key sheet
1
1
2
MX-M565N  MX-EB11  24 – 1
MX-M565N
Service Manual
 
[24] MX-EB11
1.  Unpacking
A. Packed items check
*: Used only in Brazil, South Africa and Taiwan.
2.  Installation
Before installation, be sure to turn both the operation and main
power switches off and disconnect the power plug from the power
outlet. Make double sure that the data lamp on the operation panel
does not light up or blink when performing installation. 
A. Left cabinet and shield plate removal
1) Remove the left cabinet.
2) Remove the shield plate.
B. Scanner function expansion PWB installation
1)
Connect the scanner function expansion PWB to the MFP con-
trol PWB, and fit it with the screw included in the package.
Fix the earth spring plate(Packed items No.3) together with the
board. (Only for Brazil, South Africa and Taiwan)
C. Shield plate and left cabinet installation
1)
Install the shield plate.
2)
Install the left cabinet.
D. Turn ON the power of the main unit
1)
Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
No.
Name
Quantity
1
Scanner function expansion PWB
1
2
Screw
2
3*
Earth plate spring (Parts Code: MSPRP3009FCZZ)
1
1
2
3
2
1
1
2
2
1
1
1
2
2
1
2
MX-M565N  MX-EB11  24 – 2
E. Firmware Update
1) Trouble code “E7-47” appears. It means MFP & MX-EB11
board incompatible.
2) Execute SIM49-10 "ACU UPDATE". 
* Only in case the option board connect sensor "ON" SIM49-10
appears on the screen.
3) As shown below, "COMPLETE" appears. Then press OK to
finish.
4) Restart the MFP.  
All procedures are completed. .
F. Confirmation of connection
1) Execute SIM22-10 to check to confirm that the combined
machine recognizes the MX-EB11.
 
   S I MU L A TI O N   NO . 4 9- 1 0
     
0
T E S T
C LO S E
P RE S S  [ E XE C UT E ]  T O  U P D AT E  A C U  F I RM W AR E
A C U  U PD A TE
10 K EY
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A C K
M O NO
C OL O R
E X I T
C L EA R
A R E  Y O U  S UR E ?
YE S
N O
E XE C UT E
 
   S I MU L A TI O N   NO . 4 9- 1 0
     
0
T E S T
C LO S E
P RE S S  [ E XE C UT E ]  T O  U P D AT E  A C U  F I RM W AR E
A C U  U PD A TE
10 K EY
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A C K
M O NO
C OL O R
E X I T
C L EA R
A R E  Y O U  S UR E ?
YE S
N O
E XE C UT E
 
   S I MU L A TI O N   NO . 4 9- 1 0
     
0
T E S T
C LO S E
         S* * ** * **                      E
         RE M AI N S  F O R  1  M I N UT E S.
         CA U TI O N  D O  N O T  P O WE R  O F F  T H E  M FP !   FI R MW A R E  U PD A T E  I N  P RO G R ES S !
A C U  U PD A TE
10 K EY
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A C K
M O NO
C OL O R
E X I T
C L EA R
 
   S I MU L A TI O N   NO . 4 9- 1 0
     
0
T E S T
C LO S E
C OM P L ET E  :   PL E A SE   TO U C H  [ OK ]   TO   FI N IS H .
A C U  U PD A TE
10 K EY
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0K E Y
10 K E Y
10 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A C K
M O NO
C OL O R
E X I T
C L EA R
OK
MX-M565N  MX-EB12N  25 – 1
MX-M565N
Service Manual
 
[25] MX-EB12N
1. Unpacking
A. Packed items check
Note for installing the mirroring kit
Before installing the mirroring kit, fully understand the descriptions
below and careful follow the instructions.
Prohibited items
When installing a mirroring kit newly, do not install a mirroring kit
which has been used. 
When a mirroring kit which has been used is installed in new instal-
lation of the mirroring kit, the mirroring kit HDD will overwrite the
machine HDD which has been original installed, deleting the user
data and causing a freeze of the machine.
“A mirroring kit which has been used” includes one which was only
installed and conducted.
When removing the HDD after installing the mirroring kit, be sure to
remove the both HDD’s. If only one HDD is removed and rein-
stalled, the data on the both HDD's data may be out of synchroni-
zation.
When removing the HDD, first disconnect the HDD SATA connec-
tor of the MFP PWB. This procedure brings the machine into the
state where the both HDD's are disconnected from the machine
simultaneously.
Countermeasures
If a mirroring kit which has been used must be installed at any cost,
delete the mirroring information of the HDD before installing. (For
details, refer to “5. Deleting the HDD mirroring information” 
described later.)
2. Installation
Before installation, be sure to turn both the operation and main
power switches off and disconnect the power plug from the power
outlet. Make double sure that the data lamp on the operation panel
does not light up or blink when performing installation. 
1. Left cabinet and shield plate removal
1) Remove the left cabinet.
2) Remove the shield plate.
2. Mirroring unit attachment
1) Before attachment of the mirroring kit, remove the protection
sheet from the mirroring kit.
No.
Name
Quantity
1
Mirroring unit
1
2
Screw
3
1
2
2
1
1
2
2
1
1
1
2
Page of 127