MX-M232D  (ADJUSTMENT) 12 - 3
<Adjustment specification>
c.Rear edge void adjustment (SIM50-1, SIM50-19)
1) Set a scale as shown in the figure below.
2) Set the document size to A4 (8.5" x 11"), and make a copy at 100%.
3) If necessary, perform the following adjustment procedure.
4) Execute SIM50-01 and select “DEN-B” with the arrow keys.
 
The currently set adjustment value is displayed.
5) Enter the set value and press the start key. The correction value is 
stored and a copy is made.
<Adjustment specification>
d. Paper off center adjustment (SIM50-10)
1)  Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and 
the test chart. If necessary, perform the following adjustment 
procedure.
3) Execute SIM 50-10. After completion of warm-up, shading is 
performed and the currently set off center adjustment value of each 
paper feed port is displayed.
4) Enter the set value and press the start key. The correction value is 
stored and a copy is made.
<Adjustment specification>
e.Side edge void area adjustment (SIM26-43)
Note:Before performing this adjustment, be sure to check that the paper 
off center adjustment (SIM 50-10) is completed.
1) Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and 
the test chart. If necessary, perform the following adjustment 
procedure.
3) Execute SIM 26-43 and set the density mode to SIDE VOID (L), 
SIDE VOID (R).
 
The currently set adjustment value is displayed.
4) Enter the set value and press the start key. The correction value is 
stored.
<Adjustment specification>
Adjustment mode
 SIM
Display 
text 
array
 Set value  Spec value
 Set 
range
SPF image lead 
edge position
(1st print surface)
 SIM
 
50-6
SIDE1 1 step: 
0.1mm 
shift
Lead edge 
void:
 
1 - 4mm
Image loss: 
3mm or 
less
 1 - 99
Mode
 SIM
 Display 
text array
 Set value
 Specifi- 
cation
 Set 
range
Rear edge void
 SIM 
50-1
DEN-B
1 step: 
0.1mm shift
4mm or 
less
 1 - 99
 
A4(8.5"  x 11")
Paper rear edge
Scale image
Paper rear edge
Void amount (Standard value: 4mm or less) 
Adjustment 
mod
SIM
Display 
text array
 Set value
 Specifi- 
cation
 Set 
range
Tray1
 SIM 
50-10
TRAY1
Add 1: 
0.1mm shift 
to R side. 
Reduce 1: 
0.1mm shift 
to L side.
Single:
 
Center
 
±2.0mm
 1 - 99
Tray2
TRAY2
Tray3
TRAY3
Tray4
TRAY4
Manual paper 
feed tray
BYPASS
Duplex 
(Second print 
surface)
DUPLEX
Adjustment 
mode
 SIM
Display 
text array
 Set value
 Specifi-
cation
 Set 
range
Side void (left)
26-43
SIDE 
VOID (L)
1 step: 
0.5mm shift
 0.5 - 4mm  1 - 99
Side void 
(right)
SIDE 
VOID (R)
Sim50-10 PRT. CENTER
1:TRAY1
2:TRAY2
3:TRAY3
1/2     [      1-  99]
50
50
50
50
Sim50-10 PRT. CENTER
4:TRAY4
5:BYPASS
6:DUPLEX
2/2     [      1-  99]
50
50
50
50
Sim26-43 SIDE  VOID
1:SIDE VOID(L)
2:SIDE VOID(R)
     [      0-  10]
3
3
3
MX-M232D  (ADJUSTMENT) 12 - 4
(2) Main scanning direction (FR direction) distortion 
balance adjustment 
1) Remove the OC glass and the right cabinet.
2) Loosen the copy lamp unit wire fixing screw.
3) Manually turn the mirror base drive pulley and bring No. 2/3 mirror 
base unit into contact with the positioning plate. At that time, if the 
front frame side and the rear frame side of No. 2/3 mirror base unit 
are brought into contact with the positioning plate at the same time, 
the mirror base unit parallelism is proper. If one of them is in contact 
with the positioning plate, perform the adjustment of 4).
4) Loosen the set screw of the scanner drive pulley which is not in 
contact with No. 2/3 mirror base unit positioning plate.
5) Without moving the scanner drive pulley shaft, manually turn the 
scanner drive pulley until the positioning plate is brought into 
contact with No. 2/3 mirror base unit, then fix the scanner drive 
pulley.
6) Put No. 2/3 mirror base unit on the positioning plate again, push the 
projections on the front frame side and the rear frame side of the 
copy lamp unit to the corner frame, and tighten the wire fixing 
screw.
(1)
(1)
(2)
(4)
(3)
(3)
Wire fixing screw
MX-M232D  (ADJUSTMENT) 12 - 5
(3) Main scanning direction (FR direction) distortion 
adjustment
This adjustment must be performed in the following cases:
• When the mirror base drive wire is replaced.
• When the lamp unit, or No. 2/3 mirror holder is replaced.
• When a copy as shown is made.
1) Set A3 (11" x 17") white paper on the original table as shown below.
2) Open the original cover and make a normal (100%) copy. 
3) Measure the width of the black background at the lead edge and at 
the rear edge.
If the width (La) of the black background at the lead edge is equal that 
(Lb) at the rear edge, there is no need to execute the following 
procedures of 4) - 7).
4) Loosen the mirror base drive pulley fixing screw on the front frame 
side or on the rear frame side.
5) Tighten the mirror base drive pulley fixing screw. 
<Adjustment specification>
La = Lb
6) Execute the main scanning direction (FR) distortion balance 
adjustment previously described in 2) again.
(4) Main scanning direction (FR direction) magnification 
ratio adjustment (SIM 48-1)
Note:Before performing this adjustment, be sure to check that the CCD 
unit is properly installed.
1) Put a scale on the original table as shown below.
2) Execute SIM 48-1.
3) After completion of warming up, shading is operated and the 
current correction value of the main scanning direction 
magnification ratio is displayed on the screen. 
4) Enter the set values of the items of F and R, and press [START] 
key. 
 
The correction values are saved and a copy is made.
Lb
La
Original
Copy
Paper exit 
direction
Fit the paper edge and
 the glass holding plate edge. 
A3 (11" x 17") white paper
Glass holding plate
Allow a little space. 
Paper exit direction
La: Lead edge black background width
Lb: Rear edge black background width
A
B
Rear side
Front side
When La < Lb
Turn the mirror base drive pulley on the front frame side in the
arrow direction A.
(Do not move the mirror base drive pulley shaft.)
When La > Lb
Turn the mirror base drive pulley on the rear frame side in the
arrow direction A.
(Do not move the mirror base drive pulley shaft.)
Sim48-1 COPY MAG.
1:F-R
2:SCAN
     [      1-  99]
50
50
50
MX-M232D  (ADJUSTMENT) 12 - 6
<Adjustment specification>
Note: A judgment must be made with 200mm width, and must not be 
made with 100mm width.
(5) Sub scanning direction (scanning direction) 
magnification ratio adjustment (SIM 48-1, SIM 48-5)
a. OC mode in copying (SIM48-1)
Note:Before performing this adjustment, be sure to check that the CCD 
unit is properly installed. 
1) Put a scale on the original table as shown below, and make a 
normal (100%) copy.
2) Compare the scale image and the actual image. If necessary, 
perform the following adjustment procedures. 
3) Execute SIM 48-1.
4) After completion of warming up, shading is operated and the 
current correction value of the sub scanning direction magnification 
ratio is displayed on the screen.
5) Select [2.SCAN] mode with the cross cursor.
6) Enter the set value and press the start key.
 
The set value is stored and a copy is made.
<Adjustment specification>
b. RSPF sub scanning direction magnification ratio (SIM48-5)
Note:
•Before performing this adjustment, be sure to check that the CCD unit 
is properly installed.
•Before performing this adjustment, the OC mode adjustment in 
copying must be completed.
1) Put a scale on the original table as shown below, and make a 
normal (100%) copy to make a test chart.
Note:Since the printed copy is used as a test chart, put the scale in 
parallel with the edge lines.
2) Set the test chart on the SPF and make a normal (100%) copy. 
3) Compare the scale image and the actual image. If necessary, 
perform the following adjustment procedures. 
4) Execute SIM 48-5.
5) After warm-up, shading is performed.
6) Check to confirm that the RSPF (SIDE1) mode is selected with the 
cross cursor.
7) Enter the set value and press the start key.
 
The set value is stored and a copy is made. 
<Adjustment specification>
* “RSPF (SIDE2)” is displayed only when the RSPF is installed.
(6) Off center adjustment (SIM 50-12)
a. OC mode (SIM50-12)
1) Make a test chart as shown below and set it so that its center line is 
fit with the original guide center mark.
* To make a test chart, draw a line on A3 or 11" x 17" paper at the 
center in the paper transport direction.
2) Make a normal copy from the manual paper feed tray, and compare 
the copy and the test chart.
 
If necessary, perform the following adjustment procedures. 
3) Execute SIM 50-12. 
Adjustment mode
SIM
Display 
text 
array
 Set 
value
Specifi-
cations
Set 
range
Main scanning 
direction magnifi-
cation ratio
48-1
F-R
+1 
 
+0.1%
-1 
 
0.1%
Normal ± 
1.0%
1 - 99
Adjustment mode
SIM
Display 
text 
array
Set 
value
Specifi-
cations
Set 
range
Sub scanning 
direction 
magnification ratio 
OC mode
48-1
SCAN
+1 
 
+0.1%
-1 
 
0.1%
Normal ± 
1.0%
1 - 99
Sim48-1 COPY MAG.
1:F-R
2:SCAN
     [      1-  99]
50
50
50
Sim48-1 COPY MAG.
1:F-R
2:SCAN
     [      1-  99]
50
50
50
Adjustment mode
SIM
Display 
text 
array
Set 
value
Specifi-
cations
Set 
range
Sub scanning 
direction 
magnification 
ratio
(Front surface)
48-5
RSPF
(SIDE1)
+1 
 
+0.1%
-1 
 
0.1%
Normal ± 
1.0%
1 - 99
Sub scanning 
direction 
magnification 
ratio
(Back surface)
RSPF
(SIDE2)
Sim48-5 (R)SPF ZOOM
1:RSPF(SIDE1)
2:RSPF(SIDE2)
     [      1-  99]
50
50
50
Center
Original guide
Copy paper 
(A3 or 17" x 11")
Page of 40
Display

Click on the first or last page to see other MX-M182 / MX-M182D (serv.man4) service manuals if exist.