MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 53
Process control 
Enable/Disable 
setting
D
HUM_LIMIT
HUM judgment is made when turning 
ON the power and after passing TIME.
Color process control 
Enable
0 - 2
0
0
Process control Disable
1
BK process control 
Enable
2
Process control 
Enable/Disable 
setting
E
HUM
The temperature and humidity in side 
the machine are monitored only during a 
job for every 2hours (set by item N). 
When the changes in the temperature 
and the humidity are greater than the 
specified level (the set value of item O) 
in comparison with the previous process 
control.
Color process control 
Enable
0 - 2
0
0
Process control Disable
1
BK process control 
Enable
2
F
REV1
YES
The accumulated traveling distance of 
BK or M position OPC unit reaches the 
specified level after turning the power.
Enable
0 - 1
0
0
NO
Inhibit
1
G
REV2_BK
YES
The accumulated traveling distance of 
BK position OPC drum unit reaches the 
specified level from execution of the 
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
H
REV2_CL
YES
The accumulated traveling distance of M 
position OPC drum unit reaches the 
specified level from execution of the 
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
I
REFRESH MODE 
(Not used)
YES
Select of YES/NO of the manual process 
control key with key operation
Key operation display
0 - 1
0
1
NO
Key operation NO 
display
1
Process control 
conditions setting
J
DAY
When the next warm-up if there is no 
color job after a color job after passing 
the specified days from execution of the 
previous color process control
Disable of the specified 
days judgment
0 - 999
0
1
1 - 999 days passing
1 - 999
K
PIX_RATIO_BK
Magnification ratio setting (%) of the BK toner count specified value 
entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
L
PIX_RATIO_CL
Magnification ratio setting (%) of the color (CMY) toner count 
specified value entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
M
INTERVAL TIME
Passing time setting of "TIME" (h: hour)
1-255 
(1-255: 1-255h passed)
12
N
HUM HOUR
Interval setting of the temperature and humidity monitoring time of 
"HUM" (h: hour)
1 - 24
2
O
HUM_DIF
Area difference specified value when compared with the execution 
of the previous process control of "HUM”
1 - 9
2
P
BK_RATIO
Magnification ratio setting (%) of the specified value of the BK 
position OPC drum traveling distance of "REV2_BK”
1-999
(Entry of 20 corresponds 
to 100,000mm.)
15
Q
M_RATIO
Magnification ratio setting (%) of the M position OPC drum traveling 
distance of "REV2_CL”
1-999
(Entry of 20 corresponds 
to 100,000mm.)
10
R
COLOR BORDER
Magnification ratio setting (%) of the M 
position OPC drum traveling distance 
when executing the BK process control
0 - 999
0
20
1 - 999(%)
1 - 999
S
BK ONLY
Disable/Enable setting and setting of the 
number of repetition of the BK process 
control when monochrome print is 
continued.
Enable 5 time
0 - 6
0
5
Disable 1-5 times
1 - 5
Inhibit
6
T
HT_DIF
Bias change difference value used for judgment of HT process 
control
1 - 255
40
Registration 
adjustment 
setting
U
RG_ON_SYNC
CL
Select of synchronous/asynchronous of the power ON process 
control
0 - 2
0
0
ALL
1
CL/BK
2
V
RG_TEMP_TIMER
Execution timing setting after turning ON the power
0 - 240 (MINUTE)
0
W
RG_PERM_TIMER
Span setting from execution Disable to Enable
0 - 15 (HOUR)
1
X
RG_HOUR_TIMER
Span setting of timer execution
0-15 (Above)+(HOUR)
5
Secondary 
transfer cleaning 
setting
Y
2TRAN_CLEAN_TIME1
Secondary transfer cleaning process time judgment threshold 
value 1
1 - 999
200
Z
2TRAN_CLEAN_TIME2
Secondary transfer cleaning process time judgment threshold 
value 2
1 - 999
300
AA
2TRAN_CLEAN_TIME3
Secondary transfer cleaning process time judgment threshold 
value 3
1 - 999
500
Mode
Item/Display
Content
Setting range
Default 
value
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 54
: ’11/Mar/15
1
• MX-B400P/B380P/B382P
1
Mode
Item/Display
Content
Setting range
Default 
value
Process control 
Enable/Disable 
setting
A
INITIAL
YES
When warm-up after clearing the counter 
of the OPC drum and the developer unit
Enable
0 - 1
0
0
NO
Disable
1
B
SW ON
When supplying the power (when 
clearing shut-off.)
Process control Disable
1 - 3
1
3
BK process control 
Enable
2
Pixel count judgment 
(Judgment is based on 
the setting value of item 
K, L.)
3
C
TIME
After passing the specified time from 
leaving READY continuously (Time can 
be changed by INTERVAL TIME)
Process control Disable
1 - 3
1
3
BK process control 
Enable
2
Pixel count judgment
(Judgment is based on 
the setting value of item 
K, L.)
3
D
HUM_LIMIT
HUM judgment is made when turning 
ON the power and after passing TIME.
Process control Disable
1 - 2
1
2
BK process control 
Enable
2
E
HUM
The temperature and humidity in side 
the machine are monitored only during a 
job for every 2hours (set by item N). 
When the changes in the temperature 
and the humidity are greater than the 
specified level (the set value of item O) 
in comparison with the previous process 
control.
Process control Disable
1 - 2
1
2
BK process control 
Enable
2
F
REV1
YES
The accumulated traveling distance of 
BK or M position OPC unit reaches the 
specified level after turning the power.
Enable
0 - 1
0
0
NO
Inhibit
1
G
REV2_BK
YES
The accumulated traveling distance of 
BK position OPC drum unit reaches the 
specified level from execution of the 
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
H
REFRESH MODE 
(Not used)
YES
Select of YES/NO of the manual process 
control key with key operation
Key operation display
0 - 1
0
1
NO
Key operation NO 
display
1
I
DAY
When the next warm-up if there is no job 
after a job after passing the specified 
days from execution of the previous 
process control
Disable of the specified 
days judgment
0 - 999
0
1
1 - 999 days passing
1 - 999
Process control 
conditions setting
J
PIX_RATIO_BK
Magnification ratio setting (%) of the BK toner count specified value 
entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
K
INTERVAL TIME
Passing time setting of "TIME" (h: hour)
1-255 
(1-255: 1-255h passed)
12
L
HUM HOUR
Interval setting of the temperature and humidity monitoring time of 
"HUM" (h: hour)
1 - 24
2
M
HUM_DIF
Area difference specified value when compared with the execution 
of the previous process control of "HUM”
1 - 9
2
N
BK_RATIO
Magnification ratio setting (%) of the specified value of the BK 
position OPC drum traveling distance of "REV2_BK”
1-999 
(Entry of 20 corresponds 
to 100,000mm.)
15
O
HT_DIF
Bias change difference value used for judgment of HT process 
control
1 - 255
40
Secondary 
transfer cleaning 
setting
P
2TRAN_CLEAN_TIME1
Secondary transfer cleaning process time judgment threshold 
value 1
1 - 999
200
Q
2TRAN_CLEAN_TIME2
Secondary transfer cleaning process time judgment threshold 
value 2
1 - 999
300
R
2TRAN_CLEAN_TIME3
Secondary transfer cleaning process time judgment threshold 
value 3
1 - 999
500
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 55
 
44-29
Purpose
Setting
Function (Purpose) Used to set the operating conditions of the
process control during a job.
Section
Process
Operation/Procedure
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
HV: High density process control
HT: Halftone process control
PHT: Not operate
 
44-31
Purpose
Adjustment/Setup
Function (Purpose) Used to adjust the OPC drum phase. (Man-
ual adjustment) (MX-C400P/C380P)
Section
Process
Operation/Procedure
NOTE: For the OPC drum phase adjustment, do not use this simu-
lation, but use SIM50-22 (auto adjustment).
1)
Select item A.
2)
Set the set value corresponding to the adjustment pattern.
(Enter the set value and press [OK] key and OSA shortcut
key.)
3)
Select [EXECUTE] button, and press [OK] key. (The adjust-
ment pattern is printed out.)
4)
Select an adjustment pattern whose deflection is within two
scale lines on the adjustment pattern of C, M, Y colors.
5)
Select item B.
6)
Set the adjustment pattern sheet number selected in proce-
dure 4). (Enter the set value, and press [OK] key and OSA
shortcut key.)
7)
Select [EXECUTE] button, and press [OK] key.
8)
The adjusted adjustment pattern is printed.
 
44-37
Purpose
Adjustment/Setup
Function (Purpose) Used to set the development bias correc-
tion level in the continuous printing opera-
tion.
Section
Operation/Procedure
1) Select a set target color.
2) Select a target item.
3)
Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
NOTE: When the print density is varied in the continuous printing
operation, this simulation is used.
• MX-C400P/C380P
Item/Display
Content
Setting range
Default 
value
A
PRINTER
During print job
0 - 4
0: No execution
1: HV only
2: HV 
 PHT
3: HV 
 HT
4: HV 
 PHT  HT
4
B
SELF 
PRINT
During self 
print
4
Item/Display
Content
Setting range
Default value
A
PRINT MODE
45deg
Print mode
45 
degrees
Deflection check pattern print for every 45 degrees (8-sheet print) 
(1)0
 (2)45 (3)90(4)135 (5)180 (6)225 (7)270 (8)315
* The number in () is printed on the output pattern.
1
1  -  3
(SET VALUE)
90deg
90 
degrees
Deflection check pattern print for every 90 degrees (4-sheet print) 
(1)0
 (2)90 (3)180 (4)270
* The number in () is printed on the output pattern.
2
SET 
VALUE
SET 
VALUE
Deflection check pattern print at the set value (1-sheet print)
3
B
COLOR
Phase adjustment 
value BK
CL
Angle step 0
 (1)  45 (2)  90 (3)  135 (4)  180 (5)  
225
 (6)  270 (7)  315 (8)
1 - 8
1
C
PAPER
MFT
Tray selection
Manual paper feed
1
1 - 5
(CS1)
CS1
Tray 1
2
CS2
Tray 2
3
CS3
Tray 3
4
CS4
Tray 4
5
Item/Display
Default value
Black
CMY
Black
CMY
Variable range
Current DV Bias 
voltage
Low speed mode
Heavy paper mode
less than 300[v]
A
A
0
0
0-5
 (*1)
300[v] or more, less than 450[v]
B
B
0
0
450[v] or more
C
C
0
0
Middle speed mode
less than 300[v]
D
D
0
0
300[v] or more, less than 450[v]
E
E
0
0
450[v] or more
F
F
0
0
High speed mode
Monochrome mode
less than 300[v]
G
-
0
-
300[v] or more, less than 450[v]
H
-
0
-
450[v] or more
I
-
0
-
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 56
: ’11/Mar/15
1
<Use example>
(*1)
Make multi print of 10 sheets. If the density of 10th sheet is greater than that of the first sheet, decrease the set value.
Make multi print of 10 sheets. If the density of 10th sheet is smaller than that of the first sheet, increase the set value.
When the set value is 0 (Default), the correction level does not work.
• MX-B400P/B380P/B382P
<Use example>
 
44-43
Purpose
Data display
Function (Purpose) Used to display the identification informa-
tion of the developing unit.
Section
Developing system
Operation/Procedure
The identification number and the identification signal level of the
developing unit are displayed.
• MX-C400P/C380P
• MX-B400P/B380P
• MX-B382P
 
44-61
Purpose
Adjustment/Setup
Function (Purpose) Used to set the calibration data of the color
image sensor (image registration sensor F).
Section
Operation/Procedure
1)
Select an item to be set.
2)
Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
The set value is indicated on the label attached to the registra-
tion sensor unit.
Time (T) from 
termination of 
continuous outputs 
to start of the next 
output operation
Low speed mode
Heavy paper mode
Less than 10 [sec] & after process control JOB
J
G
4
4
1-12
10 [sec] or more, less than 60 [sec]
K
H
3
3
60 [sec] or more, less than 240 [sec]
L
I
1
1
240 [sec] or more
M
J
1
1
Middle speed mode
Less than 10 [sec] & after process control JOB
N
K
4
4
10 [sec] or more, less than 60 [sec]
O
L
3
3
60 [sec] or more, less than 240 [sec]
P
M
1
1
240 [sec] or more
Q
N
1
1
High speed mode
(Not used)
Less than 10 [sec] & after process control JOB
R
-
4
-
10 [sec] or more, less than 60 [sec]
S
-
3
-
60 [sec] or more, less than 240 [sec]
T
-
1
-
240 [sec] or more
U
-
1
-
Item/Display
Default value
Black
CMY
Black
CMY
Variable range
Item/
Display
Default 
value
Variable 
range
Current DV 
Bias voltage
less than 300[v]
A
0
0-5 (*1)
300[v] or more, less than 
450[v]
B
0
450[v] or more
C
0
Time (T) from 
termination 
of continuous 
outputs to 
start of the 
next output 
operation
Less than 10 [sec] & 
after process control 
JOB
D
4
1-12 (*2)
10 [sec] or more, less 
than 60 [sec]
E
3
60 [sec] or more, less 
than 240 [sec]
F
1
240 [sec] or more
G
1
(*1) The default of A/B/C is "0" and this function is set to OFF.
When 10 sheets are copied in the multi copy mode and if the 10th 
sheet is lighter than the 1st sheet, set to the range of 1 - 5. The 
greater the value is, the darker the density of the 10th sheet is.
(*2) The correction amount is adjusted by the length of the leaving time. 
When (*1) is 1 - 5, the greater the value of (*2), the greater the density 
when starting printing is.
Item/Display
Content
Display 
range
A
DVCH KIND K
K color development unit identification 
number
1 - 9
B
DVCH KIND C
C color development unit identification 
number
1 - 9
C
DVCH KIND M
M color development unit identification 
number
1 - 9
D
DVCH KIND Y
Y color development unit identification 
number
1 - 9
E
DVCH_AD_K
K color developing unit identification 
number AD value
0 - 255
1
F
DVCH_AD_C
C color developing unit identification 
number AD value
0 - 255
G
DVCH_AD_M
M color developing unit identification 
number AD value
0 - 255
H
DVCH_AD_Y
Y color developing unit identification 
number AD value
0 - 255
Item/Display
Content
Display 
range
A
DVCH KIND K
Development unit identification number
1 - 9
B
DVCH_AD_K
Developing unit identification number 
AD value
0 - 255
Item/Display
Content
Display 
range
A
DVCH KIND K
K color development unit 
identification number
1 - 9 (*1)
B
DV_TYP_SEL_K
K color development unit type value
0 - 1 (*2)
C
DVCH_AD_K
K color developing unit identification 
number AD value
0 - 255
(*1)
The type of the developing unit is identified by the ID number. For ID 
and the types of developing units, refer to "List of developing units" 
shown below.
(*2)
0 = High (OPEN) / 1 = Low (GND)