MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 47
44-4
Purpose
Setting
Function (Purpose) Used to set the conditions of the high den-
sity process control operation.
Section
Process
Operation/Procedure
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
NOTE: Set the items to the default values unless a change is spe-
cially required.
• MX-C400P/C380P
• MX-B400P/B380P/B382P
44-6
Purpose
Adjustment
Function (Purpose) Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
Select [EXECUTE] button, and press [OK] key.
In case of a normal completion, the result is saved.
In case of an abnormal completion, "ERROR" is displayed.
(Refer to the table below.)
In case of an ERROR, the previous correction data are saved.
Select [EXECUTE] button, and press [OK] key.
In case of a normal completion, the result is saved.
In case of an abnormal completion, "ERROR" is displayed.
(Refer to the table below.)
In case of an ERROR, the previous correction data are saved.
G
REG_R LED ADJ
Image density sensor light
emitting quantity
adjustment value
emitting quantity
adjustment value
1 - 255
32
H
REG_R DARK
Image density sensor dark
voltage
voltage
0 - 255
0
I
REG_R GRND
Belt base detection level
when completion of Item
G adjustment
when completion of Item
G adjustment
0 - 256
0
J
REG_R BELT MAX
Maximum value of belt
base detection level
base detection level
0 - 255
0
K
REG_R BELT MIN
Minimum value of belt
base detection level
base detection level
0 - 255
0
L
REG_R BELT DIF
Belt base detection level
difference (Item J - Item K)
difference (Item J - Item K)
0 - 255
0
M
REG_R PATCH (K)
Patch detection level for
check
check
0 - 255
0
Error name
Error content
Image density sensor
adjustment abnormality
adjustment abnormality
PCS_K LED ADJ error
The target is not reached by 3 times of retry.
The target is not reached by 3 times of retry.
Substrate scan abnormality
PCS_K GRND error
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Registration sensor R
adjustment abnormality
adjustment abnormality
REG_R LED ADJ error
The target is not reached by 3 times of retry.
The target is not reached by 3 times of retry.
Registration substrate R
scan abnormality
scan abnormality
REG_R GRND error
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Item/Display
Content
Setting
range
Default
value
A
PCS_CL TARGET
Color sensor target set
value
value
1 - 255
98
B
PCS_K TARGET
Black sensor target set
value
value
1 - 255
208
C
LED_CL OUTPUT
Color sensor light
emitting quantity set
value
emitting quantity set
value
1 - 255
21
D
LED_K OUTPUT
Black sensor light
emitting quantity set
value
emitting quantity set
value
1 - 255
21
E
PCS ADJSTMENT
LIMIT
LIMIT
Sensor adjustment
target limit value
target limit value
1 - 255
4
F
BELT GROUND DIF
Effective difference
between the belt 1 circuit
substrate upper and
lower limit values
between the belt 1 circuit
substrate upper and
lower limit values
1 - 255
1
G
BIAS_CL
STANDARD DIF
STANDARD DIF
Bias (for color) reference
calculation difference
calculation difference
0 - 255
60
H
BIAS_BK
STANDARD DIF
STANDARD DIF
Bias (for black)
reference calculation
difference
reference calculation
difference
0 - 255
0
I
BIAS PATCH
INTERVAL
INTERVAL
Patch bias output
interval
interval
1 - 255
60
Display/Item
Content
Range
Default
J
Y_PAT TARGET ID
Patch density standard
value (yellow)
value (yellow)
1 - 255
115
K
M_PAT TARGET ID
Patch density standard
value (magenta)
value (magenta)
1 - 255
124
L
C_PAT TARGET ID
Patch density standard
value (cyan)
value (cyan)
1 - 255
111
M
K_PAT TARGET ID
Patch density standard
value (black)
value (black)
1 - 255
4
N
HV BK_GROUND
LIMIT
LIMIT
Patch position substrate
light receiving effective
range value
light receiving effective
range value
1 - 255
60
Item/Display
Content
Setting
range
Default
value
A
PCS_K TARGET
Image density sensor
target set value
target set value
1 - 255
208
B
LED_K OUTPUT
Image density sensor
light emitting quantity
set value
light emitting quantity
set value
1 - 255
32
C
PCS ADJSTMENT
LIMIT
LIMIT
Sensor adjustment
target limit value
target limit value
1 - 255
4
D
BELT GROUND DIF
Effective difference
between the belt 1
circuit substrate upper
and lower limit values
between the belt 1
circuit substrate upper
and lower limit values
1 - 255
1
E
BIAS_BK
STANDARD DIF
STANDARD DIF
Bias I reference
calculation difference
calculation difference
0 - 255
0
F
BIAS PATCH
INTERVAL
INTERVAL
Patch bias output
interval
interval
1 - 255
60
G
K_PAT TARGET ID
Patch density standard
value I
value I
1 - 255
4
H
HV BK_GROUND
LIMIT
LIMIT
Patch position substrate
light receiving effective
range value
light receiving effective
range value
1 - 255
60
Result display
Content description
COMPLETE
Normal complete
ERROR
Abnormal end
INTERRUPTION
Forcible interruption
Details of error display
Content description
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV _ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
Item/Display
Content
Setting
range
Default
value
1
: ’11/Mar/15
1
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 48
44-9
Purpose
Operation data display
Function (Purpose) Used to display the result data of the high
density process control operation.
Section
Image process (Photo-conductor/Develop-
ing/Transfer/Cleaning)
ing/Transfer/Cleaning)
Operation/Procedure
1) Select a target display mode. (Select a display mode button,
1) Select a target display mode. (Select a display mode button,
and press [OK] key.)
Mode
Item/Display (*: Correction value)
Content
Display
range
Default
value
CPY/PRN
(*2)
P (PROCON)
BLACK : GB ***/*** DV ***/***
High density process control GB/DV data
(KCMY)
(Actual output voltage level/base voltage level)
(KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
DV: 0 - 700
GB: 630
DV: 430
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
N(M)
(NORMAL (MIDDLE))
BLACK : GB ***/*** DV ***/***
High density normal (Medium speed display) GB/
DV data (KCMY)
(Actual output voltage level/base voltage level)
DV data (KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
DV: 0 - 700
GB: 630
DV: 430
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
N(L)
(NORMAL (LOW))
BLACK : GB ***/*** DV ***/***
High density normal (Low speed display) GB/DV
data (KCMY)
(Actual output voltage level/base voltage level)
data (KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
DV: 0 - 700
GB: 600
DV: 400
DV: 400
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
OTHER
TN/TC
TN HUD AREA
Toner control display humidity area
1 - 14
9
TN HUD DATA
Toner control display humidity AD value
0 - 1023
0
TC TMP AREA
Transfer display temperature area
1 - 9
4
TC TMP DATA
Transfer display temperature AD value
0 - 1023
0
TC HUD AREA
Transfer display humidity area
1 - 9
4
TC HUD DATA
Transfer display humidity AD value
0 - 1023
0
MD HUD AREA
Membrane decrease display humidity area
1 - 14
9
MD HUD DATA
Membrane decrease display humidity AD value
0 - 1023
0
DRUM
MD K STEP
Drum membrane decrease correction STEP
display (KCMY)
display (KCMY)
0 - 4
0
MD C STEP
MD M STEP
MD Y STEP
MD K DRUM COUNTER
MD M STEP
MD Y STEP
MD K DRUM COUNTER
Membrane decrease drum traveling distance
area (KCMY)
area (KCMY)
0 - 20
0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
VG
MD K REVISE(VG) : L *** M ***
Drum membrane decrease grid voltage
correction display (KCMY)
correction display (KCMY)
0 - 255
0
MD C REVISE(VG) : L *** M ***
MD M REVISE(VG) : L *** M ***
MD Y REVISE(VG) : L *** M ***
MD M REVISE(VG) : L *** M ***
MD Y REVISE(VG) : L *** M ***
LD
MD K REVISE(LD) : L *** M ***
Drum membrane decrease laser power voltage
correction (KCMY)
correction (KCMY)
0 - 255
0
MD C REVISE(LD) : L *** M ***
MD M REVISE(LD) : L *** M ***
MD Y REVISE(LD) : L *** M ***
MD M REVISE(LD) : L *** M ***
MD Y REVISE(LD) : L *** M ***
HV
MD K REVISE(HV) : L *** M ***
High density membrane decrease environment
GB correction display (KCMY)
GB correction display (KCMY)
0 - 255
0
MD C REVISE(HV) : L *** M ***
MD M REVISE(HV) : L *** M ***
MD Y REVISE(HV) : L *** M ***
MD M REVISE(HV) : L *** M ***
MD Y REVISE(HV) : L *** M ***
CP
MD K REVISE(CP) : L *** M ***
Drum membrane decrease environment grid
voltage correction display (KCMY)
voltage correction display (KCMY)
0 - 255
0
MD C REVISE(CP) : L *** M ***
MD M REVISE(CP) : L *** M ***
MD Y REVISE(CP) : L *** M ***
MD M REVISE(CP) : L *** M ***
MD Y REVISE(CP) : L *** M ***
DL
MD K REVISE COL (DL): L *** M ***
Drum membrane decrease discharge light
quantity correction (%)
quantity correction (%)
0 - 100
50
MD C REVISE COL (DL): L *** M ***
MD M REVISE COL (DL): L *** M ***
MD Y REVISE COL (DL): L *** M ***
MD M REVISE COL (DL): L *** M ***
MD Y REVISE COL (DL): L *** M ***
DL EV
MD K REVISE COL (DL EV): L *** M ***
Drum membrane decrease environment
discharge light quantity correction (%)
discharge light quantity correction (%)
-100 - 100
0
MD C REVISE COL (DL EV): L *** M ***
MD M REVISE COL (DL EV): L *** M ***
MD Y REVISE COL (DL EV): L *** M ***
MD M REVISE COL (DL EV): L *** M ***
MD Y REVISE COL (DL EV): L *** M ***
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 49
(*1) Differs depending on the destination.
(*2) Value on the left: Voltage level after correction
Value on the right: Base voltage level
44-12
Purpose
Operation data display
Function (Purpose)
Used to display the operation data of the
high density process control and the image
density sensor (registration sensor).
high density process control and the image
density sensor (registration sensor).
Section
Image process (Photo-conductor/Develop-
ing)
ing)
Operation/Procedure
1)
Select a display mode. (Select a display mode button, and
press [OK] key.)
press [OK] key.)
44-13
Purpose
Adjustment/Setup
Function (Purpose)
Used to perform the color image sensor
(image registration sensor F) calibration.
(image registration sensor F) calibration.
Section
Operation/Procedure
1)
Select [EXECUTE] button, and press [OK] key.
The shutter plate of the color image density sensor (image reg-
istration sensor F) is opened, and the message indicating that
the primary transfer unit is removed is displayed.
istration sensor F) is opened, and the message indicating that
the primary transfer unit is removed is displayed.
2)
Open the front cabinet of the machine and remove the waste
toner box and the primary transfer unit.
toner box and the primary transfer unit.
3)
Install the calibration jig (UKOG-0318FCZZ) of the color image
density sensor (image registration sensor F) to the sensor
housing section.
density sensor (image registration sensor F) to the sensor
housing section.
4)
Set the waste toner box, and close the right cover unit (sec-
ondary transfer unit section) and the front cabinet of the
machine.
ondary transfer unit section) and the front cabinet of the
machine.
5)
Select [EXECUTE] button, and press [OK] key.
Calibration of the color image density sensor (image registration
sensor F) is automatically performed. After completion of the oper-
ation, the adjustment result is displayed and [EXECUTE] button is
returned to the normal display.
sensor F) is automatically performed. After completion of the oper-
ation, the adjustment result is displayed and [EXECUTE] button is
returned to the normal display.
OTHER
CRUM
DESTINATION
Machine side management CRUM destination
(Main unit data)
(Main unit data)
-
CRUM
information
(*1)
MODEL TYPE
Machine model type
0 - 1
0
CRUM DEST_K
CRUM destination (CRUM data)
-
CRUM
information
(*1)
CRUM DEST_C
CRUM DEST_M
CRUM DEST_Y
CNT
PROCON COUNT HV
High density process control number of
executions
executions
0 - 99999999
0
PROCON COUNT HT
Halftone process control number of executions
0 - 99999999
0
Mode
Item/Display (*: Correction value)
Content
Display
range
Default
value
Mode
Item/Display
Content
Display
range
Default
value
TARGET
(1 page)
CARB DATA
Calibration plate
detection level
detection level
0 - 255
108
SEAL ADJ
DATA
DATA
Jig patch seal
detection level when
executing SIM 44-13
detection level when
executing SIM 44-13
1 - 255
108
ADK_SL (K)
Development
characteristics
gradient coefficient
(High density process
control operation)
characteristics
gradient coefficient
(High density process
control operation)
-9.99 -
9.99
0
ADK_INT(K)
Development
characteristics
intercept level (High
density process
control operation 0V)
characteristics
intercept level (High
density process
control operation 0V)
-999.9 -
999.9
0
TARGET (K)
High density process
control target density
level (K)
control target density
level (K)
0.00 -
255.00
0
TARGET
(C/M/Y)
(C/M/Y)
High density process
control target density
level (C/M/Y)
control target density
level (C/M/Y)
0.00 -
255.00
0
PATCH
1-5
(Page 1-2)
n-1
High density process
control nth time patch
density level 1 (n=1-
5)
control nth time patch
density level 1 (n=1-
5)
0 - 255
0
n-2
Patch data nth time
patch 2 (n=1-5)
patch 2 (n=1-5)
0 - 255
0
n-3
Patch data nth time
patch 3 (n=1-5)
patch 3 (n=1-5)
0 - 255
0
n-4
Patch data nth time
patch 4 (n=1-5)
? BK only
patch 4 (n=1-5)
? BK only
0 - 255
0
n-5
Patch data nth time
patch 5 (n=1-5)
? BK only
patch 5 (n=1-5)
? BK only
0 - 255
0
PATCH
6-10
(Page 1-2)
n-1
Patch data nth time
patch 1 (n=6-10)
patch 1 (n=6-10)
0 - 255
0
n-2
Patch data nth time
patch 2 (n=6-10)
patch 2 (n=6-10)
0 - 255
0
n-3
Patch data nth time
patch 3 (n=6-10)
patch 3 (n=6-10)
0 - 255
0
n-4
Patch data nth time
patch 4 (n=6-10)
? BK only
patch 4 (n=6-10)
? BK only
0 - 255
0
n-5
Patch data nth time
patch 5 (n=6-10)
? BK only
patch 5 (n=6-10)
? BK only
0 - 255
0
Item/Display
Content
Setting
range
Default
value
A
PCS_CL CARB OUT
Calibration plate
sensor value
sensor value
1 - 255
108
B
PCS_CL LED ADJ
Color sensor light
emitting quantity
adjustment value
emitting quantity
adjustment value
1 - 255
21
Error display
Content
SEN ADJ ERR
Color sensor adjustment error
SHUTTER OPEN ERR
Separation operation error
ERROR
Forcible stop
Mode
Item/Display
Content
Display
range
Default
value
3
‘16/Apr
3
3
3
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 50
: ’11/Mar/15
1
44-14
Purpose
Operation data display
Function (Purpose) Used to display the output level of the tem-
perature and humidity sensor.
Section
Process (OPC drum, development)/Fusing/
LSU
LSU
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
• MX-C400P/C380P, MX-B400P/B380P
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
• MX-C400P/C380P, MX-B400P/B380P
• MX-B382P
44-16
Purpose
Operation data display
Function (Purpose) Used to display the toner density control
data.
Section
Developing system
Operation/Procedure
1)
1)
Select a target color.
The toner density control data are displayed.
Select [NEXT] button and press [OK] key to switch the display
category.
The toner density control data are displayed.
Select [NEXT] button and press [OK] key to switch the display
category.
Item/Display
Content
Display range
TH_UM
Fusing upper heat roller
thermistor (center section)
detection temperature (
thermistor (center section)
detection temperature (
C),
differential input AD value
Temperature:
0 - 255
C (1C)
AD value: 0 - 1023
TH_UM_AD1
Fusing upper heat roller
thermistor compensation
sensor (center section)
detection temperature (
thermistor compensation
sensor (center section)
detection temperature (
C),
AD value
Temperature:
0.0 - 255.0
C (0.2C)
AD value: 0 - 1023
TH_UM_AD2
Fusing upper heat roller
thermistor detection sensor
(center section) AD value
thermistor detection sensor
(center section) AD value
AD value: 0 - 1023
TH_LM
Fusing lower heat roller
thermistor (side section) A/D
value, temperature (
thermistor (side section) A/D
value, temperature (
C)
Temperature:
0 - 255
C (1C)
AD value: 0 - 1023
TH_EX1
Fusing external heat roller
thermistor (center section) A/D
value, temperature (
thermistor (center section) A/D
value, temperature (
C)
Temperature:
0 - 255
C (1C)
AD value: 0 - 1023
TH_EX2
Fusing external heat roller
thermistor (side section) A/D
value, temperature (
thermistor (side section) A/D
value, temperature (
C)
Temperature:
0 - 255
C (1C)
AD value: 0 - 1023
TH_M
Temperature sensor A/D
value, temperature (
value, temperature (
C)
Temperature:
-40.0
C - 60.0 (1C)
AD value: 0 - 1023
HUD_M
Temperature sensor A/D
value, humidity (%)
value, humidity (%)
Humidity:
5.0 - 90.0% (
0.1%)
AD value: 0 - 1023
TH1_LSU
LSU thermistor 1 A/D value,
temperature (
temperature (
C)
Temperature:
5.0 - 60.0
C (0.1C)
AD value: 0 - 255
Item/Display
Content
Display range
TH_UM
Fusing upper heat roller
thermistor (main) detection
temperature (
thermistor (main) detection
temperature (
C), differential
input AD value
Temperature:
0 - 255
C (1C)
AD value: 0 - 1023
TH_UM_AD1
Fusing upper heat roller
thermistor compensation
sensor (main) detection
temperature (
thermistor compensation
sensor (main) detection
temperature (
C), AD value
Temperature:
0.0 - 255
C (0.2C)
AD value: 0 - 1023
TH_UM_AD2
Fusing upper heat roller
thermistor detection sensor
(main) AD value
thermistor detection sensor
(main) AD value
AD value: 0 - 1023
TH_UA
Fusing upper heat roller
thermistor (all) A/D value,
temperature (
thermistor (all) A/D value,
temperature (
C)
Temperature:
0 - 255
C (1C)
AD value: 0 - 1023
TH_M
Temperature sensor A/D
value, temperature (
value, temperature (
C)
Temperature:
-40.0 - 60.0
C (1C)
AD value: 0 - 1023
HUD_M
Temperature sensor A/D
value, humidity (%)
value, humidity (%)
Temperature:
5.0 - 90.0
C (0.1C)
AD value: 0 - 1023
TH1_LSU
LSU thermistor 1 A/D value,
temperature (
temperature (
C)
Temperature:
5.0 - 60.0
C (0.1C)
AD value: 0 - 255
1
1
Item/
Display
Content
Setting
range
Default
value
TONER
DEN_LT (M)
DEN_LT (M)
The current toner density sensor
output value (final value) at the
medium speed
output value (final value) at the
medium speed
1 - 255
129
TONER
DEN_ST (M)
DEN_ST (M)
The current toner density reference
value display (including all the
correction values) at the medium
speed
value display (including all the
correction values) at the medium
speed
128
TONER
DEN_LT (L)
DEN_LT (L)
The current toner density sensor
output value (final value) at the low
speed
output value (final value) at the low
speed
129
TONER
DEN_ST (L)
DEN_ST (L)
The current toner density reference
value display (including all the
correction values) at the low speed
value display (including all the
correction values) at the low speed
128
Item/Display
Content
Setting
range
Default
value
AUTO DEVE
(M)
(M)
Auto
development
adjustment
value
(At the
medium
speed)
development
adjustment
value
(At the
medium
speed)
Sensor output value
after completion of
SIM25-02
(at the medium
speed)
after completion of
SIM25-02
(at the medium
speed)
1 - 255
128
ALL (M)
All the
correction
reference
values
(At the
medium
speed)
correction
reference
values
(At the
medium
speed)
Correction reference
value which
calculated all the
correction values for
the auto
development
adjustment value
(at the medium
speed)
value which
calculated all the
correction values for
the auto
development
adjustment value
(at the medium
speed)
AUTO DEVE
(L)
(L)
Auto
development
adjustment
value
(At the low
speed)
development
adjustment
value
(At the low
speed)
Sensor output value
after completion of
SIM25-02
(at the low speed)
after completion of
SIM25-02
(at the low speed)
ALL (L)
All the
correction
reference
values
(At the low
speed)
correction
reference
values
(At the low
speed)
Correction reference
value which
calculated all the
correction values for
the auto
development
adjustment value
(at the low speed)
value which
calculated all the
correction values for
the auto
development
adjustment value
(at the low speed)
AREA
Area
correction
value
correction
value
Correction value for
the environment
area
the environment
area
-127 -
127
0
HUD
Humidity
correction
value
correction
value
Correction value for
change in humidity
change in humidity
PRINT RATE
Print ratio
correction
value
correction
value
Correction value for
document print ratio
document print ratio
PROCON
Process
control
correction
value
control
correction
value
Correction value for
high density process
control result
high density process
control result
LIFE
Life
correction
value
correction
value
Correction value for
the developer life
the developer life
Click on the first or last page to see other MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) service manuals if exist.