MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 47
 
44-4
Purpose
Setting
Function (Purpose) Used to set the conditions of the high den-
sity process control operation.
Section
Process
Operation/Procedure
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
NOTE: Set the items to the default values unless a change is spe-
cially required.
• MX-C400P/C380P
• MX-B400P/B380P/B382P
 
44-6
Purpose
Adjustment
Function (Purpose) Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
Select [EXECUTE] button, and press [OK] key.
In case of a normal completion, the result is saved.
In case of an abnormal completion, "ERROR" is displayed. 
(Refer to the table below.)
In case of an ERROR, the previous correction data are saved.
G
REG_R LED ADJ
Image density sensor light 
emitting quantity 
adjustment value
1 - 255
32
H
REG_R DARK
Image density sensor dark 
voltage
0 - 255
0
I
REG_R GRND
Belt base detection level 
when completion of Item 
G adjustment
0 - 256
0
J
REG_R BELT MAX
Maximum value of belt 
base detection level
0 - 255
0
K
REG_R BELT MIN
Minimum value of belt 
base detection level
0 - 255
0
L
REG_R BELT DIF
Belt base detection level 
difference (Item J - Item K)
0 - 255
0
M
REG_R PATCH (K)
Patch detection level for 
check
0 - 255
0
Error name
Error content
Image density sensor 
adjustment abnormality
PCS_K LED ADJ error 
The target is not reached by 3 times of retry.
Substrate scan abnormality
PCS_K GRND error 
Effective difference between the upper and 
lower values of the belt substrate circuit, 
outside the range
Registration sensor R 
adjustment abnormality
REG_R LED ADJ error 
The target is not reached by 3 times of retry.
Registration substrate R 
scan abnormality
REG_R GRND error 
Effective difference between the upper and 
lower values of the belt substrate circuit, 
outside the range
Item/Display
Content
Setting 
range
Default 
value
A
PCS_CL TARGET
Color sensor target set 
value
1 - 255
98
B
PCS_K TARGET
Black sensor target set 
value
1 - 255
208
C
LED_CL OUTPUT
Color sensor light 
emitting quantity set 
value
1 - 255
21
D
LED_K OUTPUT
Black sensor light 
emitting quantity set 
value
1 - 255
21
E
PCS ADJSTMENT 
LIMIT
Sensor adjustment 
target limit value
1 - 255
4
F
BELT GROUND DIF
Effective difference 
between the belt 1 circuit 
substrate upper and 
lower limit values
1 - 255
1
G
BIAS_CL 
STANDARD DIF
Bias (for color) reference 
calculation difference
0 - 255
60
H
BIAS_BK 
STANDARD DIF
Bias (for black) 
reference calculation 
difference
0 - 255
0
I
BIAS PATCH 
INTERVAL
Patch bias output 
interval
1 - 255
60
Display/Item
Content
Range
Default
J
Y_PAT TARGET ID
Patch density standard 
value (yellow)
1 - 255
115
K
M_PAT TARGET ID
Patch density standard 
value (magenta)
1 - 255
124
L
C_PAT TARGET ID
Patch density standard 
value (cyan)
1 - 255
111
M
K_PAT TARGET ID
Patch density standard 
value (black)
1 - 255
4
N
HV BK_GROUND 
LIMIT
Patch position substrate 
light receiving effective 
range value
1 - 255
60
Item/Display
Content
Setting 
range
Default 
value
A
PCS_K TARGET
Image density sensor 
target set value
1 - 255
208
B
LED_K OUTPUT
Image density sensor 
light emitting quantity 
set value
1 - 255
32
C
PCS ADJSTMENT 
LIMIT
Sensor adjustment 
target limit value
1 - 255
4
D
BELT GROUND DIF
Effective difference 
between the belt 1 
circuit substrate upper 
and lower limit values
1 - 255
1
E
BIAS_BK 
STANDARD DIF
Bias I reference 
calculation difference
0 - 255
0
F
BIAS PATCH 
INTERVAL
Patch bias output 
interval
1 - 255
60
G
K_PAT TARGET ID
Patch density standard 
value I
1 - 255
4
H
HV BK_GROUND 
LIMIT
Patch position substrate 
light receiving effective 
range value
1 - 255
60
Result display
Content description
COMPLETE
Normal complete
ERROR
Abnormal end
INTERRUPTION
Forcible interruption
Details of error display
Content description
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV _ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
Item/Display
Content
Setting 
range
Default 
value
1
: ’11/Mar/15
1
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 48
 
44-9
Purpose
Operation data display
Function (Purpose) Used to display the result data of the high
density process control operation.
Section
Image process (Photo-conductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select a target display mode. (Select a display mode button,
and press [OK] key.)
Mode
Item/Display (*: Correction value)
Content
Display 
range
Default 
value
CPY/PRN 
(*2)
P (PROCON)
BLACK : GB ***/***  DV ***/***
High density process control GB/DV data 
(KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
GB: 630
DV: 430
CYAN : GB ***/***  DV ***/***
MAGENTA : GB ***/***  DV ***/***
YELLOW : GB ***/***  DV ***/***
N(M)
(NORMAL (MIDDLE))
BLACK : GB ***/***  DV ***/***
High density normal (Medium speed display) GB/
DV data (KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
GB: 630
DV: 430
CYAN : GB ***/***  DV ***/***
MAGENTA : GB ***/***  DV ***/***
YELLOW : GB ***/***  DV ***/***
N(L)
(NORMAL (LOW))
BLACK : GB ***/***  DV ***/***
High density normal (Low speed display) GB/DV 
data (KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
GB: 600
DV: 400
CYAN : GB ***/***  DV ***/***
MAGENTA : GB ***/***  DV ***/***
YELLOW : GB ***/***  DV ***/***
OTHER
TN/TC
TN HUD AREA
Toner control display humidity area
1 - 14
9
TN HUD DATA
Toner control display humidity AD value
0 - 1023
0
TC TMP AREA
Transfer display temperature area
1 - 9
4
TC TMP DATA
Transfer display temperature AD value
0 - 1023
0
TC HUD AREA
Transfer display humidity area
1 - 9
4
TC HUD DATA
Transfer display humidity AD value
0 - 1023
0
MD HUD AREA
Membrane decrease display humidity area
1 - 14
9
MD HUD DATA
Membrane decrease display humidity AD value
0 - 1023
0
DRUM
MD K STEP
Drum membrane decrease correction STEP 
display (KCMY)
0 - 4
0
MD C STEP
MD M STEP
MD Y STEP
MD K DRUM COUNTER
Membrane decrease drum traveling distance 
area (KCMY)
0 - 20
0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
VG
MD K REVISE(VG) : L ***  M ***
Drum membrane decrease grid voltage 
correction display (KCMY)
0 - 255
0
MD C REVISE(VG) : L ***  M *** 
MD M REVISE(VG) : L ***  M *** 
MD Y REVISE(VG) : L ***  M *** 
LD
MD K REVISE(LD) : L ***  M *** 
Drum membrane decrease laser power voltage 
correction (KCMY)
0 - 255
0
MD C REVISE(LD) : L ***  M ***
MD M REVISE(LD) : L ***  M ***
MD Y REVISE(LD) : L ***  M ***
HV
MD K REVISE(HV) : L ***  M ***
High density membrane decrease environment 
GB correction display (KCMY)
0 - 255
0
MD C REVISE(HV) : L ***  M ***
MD M REVISE(HV) : L ***  M ***
MD Y REVISE(HV) : L ***  M ***
CP
MD K REVISE(CP) : L ***  M *** 
Drum membrane decrease environment grid 
voltage correction display (KCMY)
0 - 255
0
MD C REVISE(CP) : L ***  M ***
MD M REVISE(CP) : L ***  M ***
MD Y REVISE(CP) : L ***  M ***
DL
MD K REVISE COL (DL): L ***  M *** 
Drum membrane decrease discharge light 
quantity correction (%)
0 - 100
50
MD C REVISE COL (DL): L ***  M ***
MD M REVISE COL (DL): L ***  M ***
MD Y REVISE COL (DL): L ***  M ***
DL EV
MD K REVISE COL (DL EV): L ***  M *** 
Drum membrane decrease environment 
discharge light quantity correction (%)
-100 - 100
0
MD C REVISE COL (DL EV): L ***  M ***
MD M REVISE COL (DL EV): L ***  M ***
MD Y REVISE COL (DL EV): L ***  M ***
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 49
(*1) Differs depending on the destination.
(*2) Value on the left: Voltage level after correction
Value on the right: Base voltage level 
 
44-12
Purpose
Operation data display
Function (Purpose)
Used to display the operation data of the
high density process control and the image
density sensor (registration sensor).
Section
Image process (Photo-conductor/Develop-
ing)
Operation/Procedure
1)
Select a display mode. (Select a display mode button, and
press [OK] key.)
 
44-13
Purpose
Adjustment/Setup
Function (Purpose)
Used to perform the color image sensor
(image registration sensor F) calibration.
Section
Operation/Procedure
1)
Select [EXECUTE] button, and press [OK] key.
The shutter plate of the color image density sensor (image reg-
istration sensor F) is opened, and the message indicating that
the primary transfer unit is removed is displayed.
2)
Open the front cabinet of the machine and remove the waste
toner box and the primary transfer unit.
3)
Install the calibration jig (UKOG-0318FCZZ) of the color image
density sensor (image registration sensor F) to the sensor
housing section. 
4)
Set the waste toner box, and close the right cover unit (sec-
ondary transfer unit section) and the front cabinet of the
machine.
5)
Select [EXECUTE] button, and press [OK] key.
Calibration of the color image density sensor (image registration
sensor F) is automatically performed. After completion of the oper-
ation, the adjustment result is displayed and [EXECUTE] button is
returned to the normal display.
OTHER
CRUM
DESTINATION 
Machine side management CRUM destination 
(Main unit data)
-
CRUM 
information 
(*1)
MODEL TYPE 
Machine model type
0 - 1
0
CRUM DEST_K
CRUM destination (CRUM data)
-
CRUM 
information 
(*1)
CRUM DEST_C
CRUM DEST_M
CRUM DEST_Y
CNT
PROCON COUNT HV
High density process control number of 
executions
0 - 99999999
0
PROCON COUNT HT
Halftone process control number of executions
0 - 99999999
0
Mode
Item/Display (*: Correction value)
Content
Display 
range
Default 
value
Mode
Item/Display
Content
Display 
range
Default 
value
TARGET
(1 page)
CARB DATA
Calibration plate 
detection level
0 - 255
108
SEAL ADJ 
DATA
Jig patch seal 
detection level when 
executing SIM 44-13
1 - 255
108
ADK_SL (K)
Development 
characteristics 
gradient coefficient 
(High density process 
control operation)
-9.99 - 
9.99
0
ADK_INT(K)
Development 
characteristics 
intercept level (High 
density process 
control operation 0V)
-999.9 - 
999.9
0
TARGET (K)
High density process 
control target density 
level (K)
0.00 - 
255.00
0
TARGET 
(C/M/Y)
High density process 
control target density 
level (C/M/Y)
0.00 - 
255.00
0
PATCH
1-5
(Page 1-2)
n-1
High density process 
control nth time patch 
density level 1 (n=1-
5)
0 - 255
0
n-2
Patch data nth time 
patch 2 (n=1-5)
0 - 255
0
n-3
Patch data nth time 
patch 3 (n=1-5)
0 - 255
0
n-4
Patch data nth time 
patch 4 (n=1-5)
? BK  only
0 - 255
0
n-5
Patch data nth time 
patch 5 (n=1-5)
? BK  only
0 - 255
0
PATCH
6-10
(Page 1-2)
n-1
Patch data nth time 
patch 1 (n=6-10)
0 - 255
0
n-2
Patch data nth time 
patch 2 (n=6-10)
0 - 255
0
n-3
Patch data nth time 
patch 3 (n=6-10)
0 - 255
0
n-4
Patch data nth time 
patch 4 (n=6-10)
? BK only
0 - 255
0
n-5
Patch data nth time 
patch 5 (n=6-10)
? BK only
0 - 255
0
Item/Display
Content
Setting 
range
Default 
value
A
PCS_CL CARB OUT
Calibration plate 
sensor value
1 - 255
108
B
PCS_CL LED ADJ
Color sensor light 
emitting quantity 
adjustment value
1 - 255
21
Error display
Content
SEN ADJ ERR
Color sensor adjustment error
SHUTTER OPEN ERR
Separation operation error
ERROR
Forcible stop
Mode
Item/Display
Content
Display 
range
Default 
value
3
‘16/Apr
3
3
3
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 50
: ’11/Mar/15
1
 
44-14
Purpose
Operation data display
Function (Purpose) Used to display the output level of the tem-
perature and humidity sensor.
Section
Process (OPC drum, development)/Fusing/
LSU
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
• MX-C400P/C380P, MX-B400P/B380P
• MX-B382P
 
44-16
Purpose
Operation data display
Function (Purpose) Used to display the toner density control
data.
Section
Developing system
Operation/Procedure
1)
Select a target color.
The toner density control data are displayed.
Select [NEXT] button and press [OK] key to switch the display
category.
Item/Display
Content
Display range
TH_UM
Fusing upper heat roller 
thermistor (center section) 
detection temperature (
C), 
differential input AD value
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_UM_AD1
Fusing upper heat roller 
thermistor compensation 
sensor (center section) 
detection temperature (
C), 
AD value
Temperature: 
0.0 - 255.0
C (0.2C)
AD value: 0 - 1023
TH_UM_AD2
Fusing upper heat roller 
thermistor detection sensor 
(center section) AD value
AD value: 0 - 1023
TH_LM
Fusing lower heat roller 
thermistor (side section) A/D 
value, temperature (
C)
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_EX1
Fusing external heat roller 
thermistor (center section) A/D 
value, temperature (
C)
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_EX2
Fusing external heat roller 
thermistor (side section) A/D 
value, temperature (
C)
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_M
Temperature sensor A/D 
value, temperature (
C)
Temperature: 
-40.0
C - 60.0 (1C)
AD value: 0 - 1023
HUD_M
Temperature sensor A/D 
value, humidity (%)
Humidity: 
5.0 - 90.0% (
0.1%)
AD value: 0 - 1023
TH1_LSU
LSU thermistor 1 A/D value, 
temperature (
C)
Temperature: 
5.0 - 60.0
C (0.1C)
AD value: 0 - 255
Item/Display
Content
Display range
TH_UM
Fusing upper heat roller 
thermistor (main) detection 
temperature (
C), differential 
input AD value
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_UM_AD1
Fusing upper heat roller 
thermistor compensation 
sensor (main) detection 
temperature (
C), AD value
Temperature: 
0.0 - 255
C (0.2C)
AD value: 0 - 1023
TH_UM_AD2
Fusing upper heat roller 
thermistor detection sensor 
(main) AD value
AD value: 0 - 1023
TH_UA
Fusing upper heat roller 
thermistor (all) A/D value, 
temperature (
C)
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_M
Temperature sensor A/D 
value, temperature (
C)
Temperature: 
-40.0 - 60.0
C (1C)
AD value: 0 - 1023
HUD_M
Temperature sensor A/D 
value, humidity (%)
Temperature: 
5.0 - 90.0
C (0.1C)
AD value: 0 - 1023
TH1_LSU
LSU thermistor 1 A/D value, 
temperature (
C)
Temperature: 
5.0 - 60.0
C (0.1C)
AD value: 0 - 255
1
1
Item/
Display
Content
Setting 
range
Default 
value
TONER 
DEN_LT (M)
The current toner density sensor 
output value (final value) at the 
medium speed
1 - 255
129
TONER 
DEN_ST (M)
The current toner density reference 
value display (including all the 
correction values) at the medium 
speed
128
TONER 
DEN_LT (L)
The current toner density sensor 
output value (final value) at the low 
speed
129
TONER 
DEN_ST (L)
The current toner density reference 
value display (including all the 
correction values) at the low speed
128
Item/Display
Content
Setting 
range
Default 
value
AUTO DEVE 
(M)
Auto 
development 
adjustment 
value 
(At the 
medium 
speed)
Sensor output value 
after completion of 
SIM25-02
(at the medium 
speed)
1 - 255
128
ALL (M)
All the 
correction 
reference 
values 
(At the 
medium 
speed)
Correction reference 
value which 
calculated all the 
correction values for 
the auto 
development 
adjustment value 
(at the medium 
speed)
AUTO DEVE 
(L)
Auto 
development 
adjustment 
value 
(At the low 
speed)
Sensor output value 
after completion of 
SIM25-02
(at the low speed)
ALL (L)
All the 
correction 
reference 
values 
(At the low 
speed)
Correction reference 
value which 
calculated all the 
correction values for 
the auto 
development 
adjustment value 
(at the low speed)
AREA
Area 
correction 
value
Correction value for 
the environment 
area
-127 - 
127
0
HUD
Humidity 
correction 
value
Correction value for 
change in humidity
PRINT RATE
Print ratio 
correction 
value
Correction value for 
document print ratio
PROCON
Process 
control 
correction 
value
Correction value for 
high density process 
control result
LIFE
Life 
correction 
value
Correction value for 
the developer life