MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 51
 
44-21
Purpose
Adjustment/Setup
Function (Purpose) Used to set the halftone process control tar-
get.
Section
Process
Operation/Procedure
Select [EXECUTE] button, and press [OK] key.
The halftone process control target is set and the operation data
are displayed.
NOTE: Though the simulation can be executed, the machine is not
affected by the simulation operation.
In this machine, this simulation is not required.
 
44-22
Purpose
Operation data display
Function (Purpose) Used to display the toner patch density
level in the halftone process control opera-
tion.
Section
Process
Operation/Procedure
The toner patch density level made in the halftone process control
operation is displayed.
 
44-24
Purpose
Operation data display
Function (Purpose) Used to display the correction target and
the correction level in the halftone process
control operation.
Section
Process
Operation/Procedure
1)
Select a target display color.
2)
Select [NEXT] button and press [OK] key to switch the display
category.
SENSITIVITY
Sensitivity 
correction 
value
Correction for the 
toner density 
sensitivity
1 - 999
500
AUTO DEVE 
VO (M)
Auto 
development 
adjustment 
control 
voltage 
(at the 
medium 
speed)
Sensor control 
voltage value after 
completion of 
SIM25-02
(at the medium 
speed)
1 - 255
128
ALL VO (M)
All the 
correction 
reference 
control 
voltages 
(at the 
medium 
speed)
Control voltage 
reference value 
which calculated all 
the correction values 
for the auto 
development 
adjustment value 
(at the medium 
speed)
AUTO DEVE 
VO (L)
Auto 
development 
adjustment 
control 
voltage 
(at the low 
speed)
Sensor control 
voltage value after 
completion of 
SIM25-02
(at the low speed)
ALL VO (L)
All the 
correction 
reference 
control 
voltages 
(at the low 
speed)
Control voltage 
reference value 
which calculated all 
the correction values 
for the auto 
development 
adjustment value 
(at the low speed)
1 - 255
128
AREA VO
Area 
correction 
control 
voltage
Control voltage 
correction value for 
the environment 
area
-127 - 
127
0
HUD VO
Humidity 
correction 
control 
voltage
Control voltage 
correction value for 
change in humidity
PRINT RATE 
VO
Print ratio 
correction 
control 
voltage
Control voltage 
correction value for 
the document print 
ratio
PROCON VO
Process 
control 
correction 
control 
voltage
Control voltage 
correction value for 
the high density 
process control 
result
LIFE VO
Life 
correction 
value control 
voltage
Control voltage 
correction value for 
the developer life
SENSITIVITY 
VO
Sensitivity 
correction 
control 
voltage
Control voltage 
correction value for 
the toner density 
sensor
1 - 999
500
ENV VO
Environment 
correction 
control 
voltage
Control voltage 
correction value for 
the high humidity 
environment
-127 - 
127
0
Item/Display
Content
Setting 
range
Default 
value
AUTO DEVE 
AREA
Area in the 
auto 
development 
adjustment
Humidity area 
display in the 
automatic developer 
adjustment
1 - 14
8
AREA
Current area
Current humidity 
area display
Item/Display
Content
Setting 
range
Default 
value
Display
Content
COMPLETE
Normal complete
ERROR COLOR SENSOR 
ADJUSTMENT
Color image density sensor sensitivity 
adjustment error
ERROR BLACK SENSOR 
ADJUSTMENT
Black image density sensor sensitivity 
adjustment error
[YMCK]
High density process control error [YMCK]
OTHER
Other errors
Item/Display
Content
ID_n
Patch data display (n=1-16)
BASE1
Belt substrate data (START)
BASE5
Belt substrate data (LAST)
Category
Item/Display
Content
Coefficient
[EX-LOW]
Coefficient of the approximation 
formula of the minimum density
[LOW]
Coefficient of the approximation 
formula of the low density
[CONNECT]
Coefficient of the approximation 
formula of when connecting the low 
density and the medium density
[MID]
Coefficient of the approximation 
formula of the medium density
[HIGH]
Coefficient of the approximation 
formula of the high density
[CONNECT POINT]
Each density section connection 
output ratio
Reference 
value
[SENSOR_TARGET]
Halftone process control reference 
value
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 52
 
44-25
Purpose
Setting
Function (Purpose) Used to set the calculating conditions of the
correction value for the halftone process
control.
Section
Process
Operation/Procedure
1) Select a target adjustment color.
2) Select a target adjustment density level.
3) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
NOTE: Set the items to the default values unless a change is spe-
cially required.
 
44-26
Purpose
Adjustment/Setup
Function (Purpose) Used to execute the halftone process con-
trol compulsorily.
Section
Process
Operation/Procedure
Select [EXECUTE] button, and press [OK] key.
The halftone process control is performed and the operation data
are displayed.
 
44-27
Purpose
Data clear
Function (Purpose) Used to clear the correction data of the half-
tone process control.
Section
Process
Operation/Procedure
1)
Select [EXECUTE] button, and press [OK] key.
2)
Select [YES] button, and press [OK] key.
The correction data of the halftone process control are cleared.
 
44-28
Purpose
Adjustment/Setup
Function (Purpose) Used to set the process control execution
conditions.
Section
Process
Operation/Procedure
1)
Select an item to be set.
2)
Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
NOTE: Set the items to the default values unless a change is spe-
cially required.
• MX-C400P/C380P
Correction 
value
[S_VALUE]
Halftone process control correction 
value
For printer
[PRINTER_S_VALUE]
Printer halftone process control 
correction value
[PRINTER_BASE
_DITHER_VALUE]
Printer halftone process control 
reference dither value
[PRINTER_AUTO_HT
_VALUE]
Printer auto density adjustment 
correction value
Previous 
correction 
value
[BEFORE S_VALUE]
Previous halftone process control 
value
Item/Display
Content
Setting 
range
Default value
K
CMY
A
LOW FIELD 
LOWER LIMIT
Low density 
approximate expression 
data lower limit value
0 - 255
98
2
B
LOW FIELD 
UPPER LIMIT
Low density 
approximate expression 
data upper limit value
0 - 255
60
40
C
MID  FIELD 
LOWER LIMIT
Medium density 
approximate expression 
data lower limit value
0 - 255
90
15
D
MID  FIELD 
UPPER LIMIT
Medium density 
approximate expression 
data upper limit value
0 - 255
6
144
E
HIGHLIGHT 
POINT
Reference point of the 
highlight correction 
amount
1 - 8
7
7
Category
Item/Display
Content
INTERRUPTION
Forcible interruption
COMPLETE
Normal complete
ERROR COLOR SENSOR 
ADJUSTMENT
Color sensor adjustment error
ERROR BLACK SENSOR 
ADJUSTMENT
Black sensor adjustment error
[YMCK]
High density process control [YMCK] error
OTHER
Other error
Mode
Item/Display
Content
Setting range
Default 
value
Process control 
Enable/Disable 
setting
A
INITIAL
YES
When warm-up after clearing the counter 
of the OPC drum and the developer unit
Enable
0 - 1
0
0
NO
Disable
1
B
SW ON
When supplying the power (when 
clearing shut-off.)
Color process control 
Enable
0 - 3
0
3
Process control Disable
1
BK process control 
Enable
2
Pixel count judgment 
(Judgment is based on 
the setting value of item 
K, L.)
3
C
TIME
After passing the specified time from 
leaving READY continuously (Time can 
be changed by INTERVAL TIME)
Color process control 
Enable
0 - 3
0
3
Process control Disable
1
BK process control 
Enable
2
Pixel count judgment
(Judgment is based on 
the setting value of item 
K, L.)
3
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 53
Process control 
Enable/Disable 
setting
D
HUM_LIMIT
HUM judgment is made when turning 
ON the power and after passing TIME.
Color process control 
Enable
0 - 2
0
0
Process control Disable
1
BK process control 
Enable
2
Process control 
Enable/Disable 
setting
E
HUM
The temperature and humidity in side 
the machine are monitored only during a 
job for every 2hours (set by item N). 
When the changes in the temperature 
and the humidity are greater than the 
specified level (the set value of item O) 
in comparison with the previous process 
control.
Color process control 
Enable
0 - 2
0
0
Process control Disable
1
BK process control 
Enable
2
F
REV1
YES
The accumulated traveling distance of 
BK or M position OPC unit reaches the 
specified level after turning the power.
Enable
0 - 1
0
0
NO
Inhibit
1
G
REV2_BK
YES
The accumulated traveling distance of 
BK position OPC drum unit reaches the 
specified level from execution of the 
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
H
REV2_CL
YES
The accumulated traveling distance of M 
position OPC drum unit reaches the 
specified level from execution of the 
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
I
REFRESH MODE 
(Not used)
YES
Select of YES/NO of the manual process 
control key with key operation
Key operation display
0 - 1
0
1
NO
Key operation NO 
display
1
Process control 
conditions setting
J
DAY
When the next warm-up if there is no 
color job after a color job after passing 
the specified days from execution of the 
previous color process control
Disable of the specified 
days judgment
0 - 999
0
1
1 - 999 days passing
1 - 999
K
PIX_RATIO_BK
Magnification ratio setting (%) of the BK toner count specified value 
entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
L
PIX_RATIO_CL
Magnification ratio setting (%) of the color (CMY) toner count 
specified value entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
M
INTERVAL TIME
Passing time setting of "TIME" (h: hour)
1-255 
(1-255: 1-255h passed)
12
N
HUM HOUR
Interval setting of the temperature and humidity monitoring time of 
"HUM" (h: hour)
1 - 24
2
O
HUM_DIF
Area difference specified value when compared with the execution 
of the previous process control of "HUM”
1 - 9
2
P
BK_RATIO
Magnification ratio setting (%) of the specified value of the BK 
position OPC drum traveling distance of "REV2_BK”
1-999
(Entry of 20 corresponds 
to 100,000mm.)
15
Q
M_RATIO
Magnification ratio setting (%) of the M position OPC drum traveling 
distance of "REV2_CL”
1-999
(Entry of 20 corresponds 
to 100,000mm.)
10
R
COLOR BORDER
Magnification ratio setting (%) of the M 
position OPC drum traveling distance 
when executing the BK process control
0 - 999
0
20
1 - 999(%)
1 - 999
S
BK ONLY
Disable/Enable setting and setting of the 
number of repetition of the BK process 
control when monochrome print is 
continued.
Enable 5 time
0 - 6
0
5
Disable 1-5 times
1 - 5
Inhibit
6
T
HT_DIF
Bias change difference value used for judgment of HT process 
control
1 - 255
40
Registration 
adjustment 
setting
U
RG_ON_SYNC
CL
Select of synchronous/asynchronous of the power ON process 
control
0 - 2
0
0
ALL
1
CL/BK
2
V
RG_TEMP_TIMER
Execution timing setting after turning ON the power
0 - 240 (MINUTE)
0
W
RG_PERM_TIMER
Span setting from execution Disable to Enable
0 - 15 (HOUR)
1
X
RG_HOUR_TIMER
Span setting of timer execution
0-15 (Above)+(HOUR)
5
Secondary 
transfer cleaning 
setting
Y
2TRAN_CLEAN_TIME1
Secondary transfer cleaning process time judgment threshold 
value 1
1 - 999
200
Z
2TRAN_CLEAN_TIME2
Secondary transfer cleaning process time judgment threshold 
value 2
1 - 999
300
AA
2TRAN_CLEAN_TIME3
Secondary transfer cleaning process time judgment threshold 
value 3
1 - 999
500
Mode
Item/Display
Content
Setting range
Default 
value
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 54
: ’11/Mar/15
1
• MX-B400P/B380P/B382P
1
Mode
Item/Display
Content
Setting range
Default 
value
Process control 
Enable/Disable 
setting
A
INITIAL
YES
When warm-up after clearing the counter 
of the OPC drum and the developer unit
Enable
0 - 1
0
0
NO
Disable
1
B
SW ON
When supplying the power (when 
clearing shut-off.)
Process control Disable
1 - 3
1
3
BK process control 
Enable
2
Pixel count judgment 
(Judgment is based on 
the setting value of item 
K, L.)
3
C
TIME
After passing the specified time from 
leaving READY continuously (Time can 
be changed by INTERVAL TIME)
Process control Disable
1 - 3
1
3
BK process control 
Enable
2
Pixel count judgment
(Judgment is based on 
the setting value of item 
K, L.)
3
D
HUM_LIMIT
HUM judgment is made when turning 
ON the power and after passing TIME.
Process control Disable
1 - 2
1
2
BK process control 
Enable
2
E
HUM
The temperature and humidity in side 
the machine are monitored only during a 
job for every 2hours (set by item N). 
When the changes in the temperature 
and the humidity are greater than the 
specified level (the set value of item O) 
in comparison with the previous process 
control.
Process control Disable
1 - 2
1
2
BK process control 
Enable
2
F
REV1
YES
The accumulated traveling distance of 
BK or M position OPC unit reaches the 
specified level after turning the power.
Enable
0 - 1
0
0
NO
Inhibit
1
G
REV2_BK
YES
The accumulated traveling distance of 
BK position OPC drum unit reaches the 
specified level from execution of the 
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
H
REFRESH MODE 
(Not used)
YES
Select of YES/NO of the manual process 
control key with key operation
Key operation display
0 - 1
0
1
NO
Key operation NO 
display
1
I
DAY
When the next warm-up if there is no job 
after a job after passing the specified 
days from execution of the previous 
process control
Disable of the specified 
days judgment
0 - 999
0
1
1 - 999 days passing
1 - 999
Process control 
conditions setting
J
PIX_RATIO_BK
Magnification ratio setting (%) of the BK toner count specified value 
entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
K
INTERVAL TIME
Passing time setting of "TIME" (h: hour)
1-255 
(1-255: 1-255h passed)
12
L
HUM HOUR
Interval setting of the temperature and humidity monitoring time of 
"HUM" (h: hour)
1 - 24
2
M
HUM_DIF
Area difference specified value when compared with the execution 
of the previous process control of "HUM”
1 - 9
2
N
BK_RATIO
Magnification ratio setting (%) of the specified value of the BK 
position OPC drum traveling distance of "REV2_BK”
1-999 
(Entry of 20 corresponds 
to 100,000mm.)
15
O
HT_DIF
Bias change difference value used for judgment of HT process 
control
1 - 255
40
Secondary 
transfer cleaning 
setting
P
2TRAN_CLEAN_TIME1
Secondary transfer cleaning process time judgment threshold 
value 1
1 - 999
200
Q
2TRAN_CLEAN_TIME2
Secondary transfer cleaning process time judgment threshold 
value 2
1 - 999
300
R
2TRAN_CLEAN_TIME3
Secondary transfer cleaning process time judgment threshold 
value 3
1 - 999
500
Page of 127