Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual ▷ View online
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 43
*1: 1 Count = 1sec Change
• MX-B400P/B380P
E
HH_120_FUS_DUP_HL_UM
Correction amount for SIM43-23-A, E at 120
C or less
in H/H-Warm Up
1 - 99
50
F
HH_120_FUS_DUP_HL_LM
Correction amount for SIM43-23-B, F at 120
C or less
in H/H-Warm Up
1 - 99
50
G
NN_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-A, B, M
(Setting of the number of sheets at which application is
started)
(Setting of the number of sheets at which application is
started)
1 - 60
5
H
LL_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-C, D, N
(Setting of the number of sheets at which application is
started)
(Setting of the number of sheets at which application is
started)
1 - 60
10
I
HH_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-E, F, O
(Setting of the number of sheets at which application is
started)
(Setting of the number of sheets at which application is
started)
1 - 60
5
J
(*1)
COOL_DOWN_HEAVY
Cool-down time heavy paper (Time (sec) required to
return to the plain paper fusing temperature)
return to the plain paper fusing temperature)
1 - 60
15
K
(*1)
COOL_DOWN_OHP
Cool-down time OHP (Time (sec) required to return to
the plain paper fusing temperature)
the plain paper fusing temperature)
1 - 60
30
L
(*1)
COOL_DOWN_ENVELOPE
Cool-down time envelope (Time (sec) required to
return to the plain paper fusing temperature)
return to the plain paper fusing temperature)
1 - 60
40
M
NN_120_FUS_DUP_HL_E
Correction amount for SIM43-4-C, G at 120
C or less
in N/N-Warm Up
1 - 99
50
N
LL_120_FUS_DUP_HL_E
Correction amount for SIM43-22-C, G at 120
C or less
in L/L-Warm Up
1 - 99
50
O
HH_120_FUS_DUP_HL_E
Correction amount for SIM43-23-C, G at 120
C or less
in H/H-Warm Up
1 - 99
50
P
HL_UM THIN PAPER BW
Thin paper BW-TH_UM
70 - 230
165
Q
HL_LM THIN PAPER BW
Thin paper BW-TH_LM
30 - 200
120
R
HL_E THIN PAPER BW
Thin paper BW-TH_E
70 - 230
195
S
HL_UM THIN PAPER CL
Thin paper COL-TH_UM
70 - 230
165
T
HL_LM THIN PAPER CL
Thin paper COL-TH_LM
30 - 200
120
U
HL_E THIN PAPER CL
Thin paper COL-TH_E
70 - 230
195
V
HL_UM THIN PAPER READY
Thin paper Ready-TH_UM
70 - 230
170
W
HL_UM REC PAPER BW
Recycled paper BW-TH_UM
70 - 230
185
X
HL_LM REC PAPER BW
Recycled paper BW-TH_LM
30 - 200
125
Y
HL_E REC PAPER BW
Recycled paper BW-TH_E
70 - 230
220
Z
HL_UM REC PAPER CL
Recycled paper COL-TH_UM
70 - 230
185
AA
HL_LM REC PAPER CL
Recycled paper COL-TH_LM
30 - 200
130
AB
HL_E REC PAPER CL
Recycled paper COL-TH_E
70 - 230
220
AC
HL_UM REC PAPER READY
Recycled paper Ready-TH_UM
70 - 230
180
Item/Display
Content
Setting
range
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
Item/Display
Content
Setting
range
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
NN_120_FUS_DUP_HL_UM
Correction amount for SIM43-4-A, E at 120
C or less in
N/N-Warm Up
1 - 99
50
B
NN_120_FUS_DUP_HL_LM
Correction amount for SIM43-4-B, F at 120
C or less in
N/N-Warm Up
1 - 99
50
C
LL_120_FUS_DUP_HL_UM
Correction amount for SIM43-22-A, E at 120
C or less
in L/L-Warm Up
1 - 99
50
D
LL_120_FUS_DUP_HL_LM
Correction amount for SIM43-22-B, F at 120
C or less
in L/L-Warm Up
1 - 99
50
E
HH_120_FUS_DUP_HL_UM
Correction amount for SIM43-23-A, E at 120
C or less
in H/H-Warm Up
1 - 99
50
F
HH_120_FUS_DUP_HL_LM
Correction amount for SIM43-23-B, F at 120
C or less
in H/H-Warm Up
1 - 99
50
G
NN_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-A, B, M
(Setting of the number of sheets at which application is
started)
(Setting of the number of sheets at which application is
started)
1 - 60
5
H
LL_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-C, D, N
(Setting of the number of sheets at which application is
started)
(Setting of the number of sheets at which application is
started)
1 - 60
10
I
HH_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-E, F, O
(Setting of the number of sheets at which application is
started)
(Setting of the number of sheets at which application is
started)
1 - 60
5
J
(*1)
COOL_DOWN_HEAVY
Cool-down time heavy paper (Time (sec) required to
return to the plain paper fusing temperature)
return to the plain paper fusing temperature)
1 - 60
15
K
(*1)
COOL_DOWN_OHP
Cool-down time OHP (Time (sec) required to return to
the plain paper fusing temperature)
the plain paper fusing temperature)
1 - 60
30
L
(*1)
COOL_DOWN_ENVELOPE
Cool-down time envelope (Time (sec) required to
return to the plain paper fusing temperature)
return to the plain paper fusing temperature)
1 - 60
40
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 44
: ’11/Mar/15
1
*1: 1 Count = 1sec Change
<Code descriptions>
• MX-B382P
*1: 1 Count = 1sec Change
<Code descriptions>
M
NN_120_FUS_DUP_HL_E
Correction amount for SIM43-4-C, G at 120
C or less
in N/N-Warm Up
1 - 99
50
N
LL_120_FUS_DUP_HL_E
Correction amount for SIM43-22-C, G at 120
C or less
in L/L-Warm Up
1 - 99
50
O
HH_120_FUS_DUP_HL_E
Correction amount for SIM43-23-C, G at 120
C or less
in H/H-Warm Up
1 - 99
50
P
HL_UM THIN PAPER BW
Thin paper BW-TH_UM
70 - 230
165
Q
HL_LM THIN PAPER BW
Thin paper BW-TH_LM
30 - 200
120
R
HL_E THIN PAPER BW
Thin paper BW-TH_E
70 - 230
195
S
HL_UM THIN PAPER READY
Thin paper Ready-TH_UM
70 - 230
170
T
HL_UM REC PAPER BW
Recycled paper BW-TH_UM
70 - 230
185
U
HL_LM REC PAPER BW
Recycled paper BW-TH_LM
30 - 200
125
V
HL_E REC PAPER BW
Recycled paper BW-TH_E
70 - 230
220
W
HL_UM REC PAPER READY
Recycled paper Ready-TH_UM
70 - 230
180
Item/Display
Content
Setting
range
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
Item/Display
Content
Setting
range
Group
A
Group
B
Group
C
A
NN_120_FUS_DUP_HL_UM
Correction amount for SIM43-4-A, E at 120
C or less in N/N-Warm Up
1 - 99
50
B
NN_120_FUS_DUP_HL_LM
Correction amount for SIM43-4-B, F at 120
C or less in N/N-Warm Up
1 - 99
50
C
LL_120_FUS_DUP_HL_UM
Correction amount for SIM43-22-A, E at 120
C or less in L/L-Warm Up
1 - 99
50
D
LL_120_FUS_DUP_HL_LM
Correction amount for SIM43-22-B, F at 120
C or less in L/L-Warm Up
1 - 99
50
E
HH_120_FUS_DUP_HL_UM
Correction amount for SIM43-23-A, E at 120
C or less in H/H-Warm Up
1 - 99
50
F
HH_120_FUS_DUP_HL_LM
Correction amount for SIM43-23-B, F at 120
C or less in H/H-Warm Up
1 - 99
50
G
NN_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-A, B, M
(Setting of the number of sheets at which application is started)
(Setting of the number of sheets at which application is started)
1 - 60
5
H
LL_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-C, D, N
(Setting of the number of sheets at which application is started)
(Setting of the number of sheets at which application is started)
1 - 60
10
I
HH_120_FUS_DUP_CNT
Number of sheets of application of SIM43-24-E, F, O
(Setting of the number of sheets at which application is started)
(Setting of the number of sheets at which application is started)
1 - 60
5
J
COOL_DOWN_HEAVY
Cool-down time heavy paper (Time (sec) required to return to the plain
paper fusing temperature)
paper fusing temperature)
1 - 60
15
K
COOL_DOWN_OHP
Cool-down time OHP (Time (sec) required to return to the plain paper
fusing temperature)
fusing temperature)
1 - 60
30
L
COOL_DOWN_ENVELOPE
Cool-down time envelope (Time (sec) required to return to the plain paper
fusing temperature)
fusing temperature)
1 - 60
40
M
NN_120_FUS_DUP_HL_US
Correction amount for SIM43-4-C, G at 120
C or less in N/N-Warm Up
1 - 99
50
N
LL_120_FUS_DUP_HL_US
Correction amount for SIM43-22-C, G at 120
C or less in L/L-Warm Up
1 - 99
50
O
HH_120_FUS_DUP_HL_US
Correction amount for SIM43-23-C, G at 120
C or less in H/H-Warm Up
1 - 99
50
P
HL_UM THIN PAPER BW
Thin paper BW-TH_UM
70 - 230
170
Q
HL_LM THIN PAPER BW
Thin paper BW-TH_LM
30 - 200
120
R
HL_US THIN PAPER BW
Thin paper BW-TH_US
70 - 230
170
S
HL_UM THIN PAPER READY
Thin paper Ready-TH_UM
70 - 230
170
T
HL_UM REC PAPER BW
Recycled paper BW-TH_UM
70 - 230
190
U
HL_LM REC PAPER BW
Recycled paper BW-TH_LM
30 - 200
125
V
HL_US REC PAPER BW
Recycled paper BW-TH_US
70 - 230
190
W
HL_UM REC PAPER READY
Recycled paper Ready-TH_UM
70 - 230
190
1
TH_UM
Fusing upper thermistor main
TH_LM
Fusing lower thermistor main
TH_US
Fusing upper thermistor sub
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_US
Heater lamp upper sub
Group
Destination
Group A
Japan
China
AB_B
–
Group B
U.S.A.
Canada
Inch
–
Group C
Europe
U.K.
AUS
AB_A
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 45
44
44-1
Purpose
Setting
Function (Purpose) Used to set each correction operation func-
tion in the image forming (process) section.
Section
Image process (Photo-conductor/Develop-
ing/Transfer/Cleaning)
ing/Transfer/Cleaning)
Operation/Procedure
1) Select an item to be set.
2) Select [EXECUTE] button, and press [OK] key. (The set value
1) Select an item to be set.
2) Select [EXECUTE] button, and press [OK] key. (The set value
is saved.)
NOTE: Set the items to the default values unless a change is spe-
cially required.
• MX-C400P/C380P
• MX-B400P/B380P/B382P
Item/Display
Content
Setting
range
Default
value
NOTE
HV
Normal operation high
density process control
Enable/Disable setting
density process control
Enable/Disable setting
Normal
(Disable
: 1 : NO)
Reverse
Reverse
(Enable :
0 : YES)
Enable
HT
Normal operation
halftone process
control Enable/Disable
setting
halftone process
control Enable/Disable
setting
Enable
TC
Transfer output
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
MD VG
Membrane decrease
grid voltage correction
Enable/Disable setting
grid voltage correction
Enable/Disable setting
Enable
MD LD
Membrane laser power
voltage correction
Enable/Disable setting
voltage correction
Enable/Disable setting
Enable
MD EV
Membrane decrease
environment grid
voltage correction
Enable/Disable setting
environment grid
voltage correction
Enable/Disable setting
Enable
MD DL
Membrane decrease
discharge light quantity
correction
Enable/Disable setting
discharge light quantity
correction
Enable/Disable setting
Enable
MD DL EV
Membrane decrease
environment discharge
light quantity
correction
Enable/Disable setting
environment discharge
light quantity
correction
Enable/Disable setting
Disable
TN_HUM
Toner density humidity
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_AREA
Toner density area
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_LIFE
Toner density life
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_COV
Toner density print
ratio correction
Enable/Disable setting
ratio correction
Enable/Disable setting
Enable
TN_PROCON
Toner density process
control correction
Enable/Disable setting
control correction
Enable/Disable setting
Enable
TN_ENV
Toner density
environment correction
Enable/Disable setting
environment correction
Enable/Disable setting
Enable
TN_DRIP
Toner density
correction
unconditional supply
Enable/Disable setting
correction
unconditional supply
Enable/Disable setting
Enable
TN_SPEND
Toner forcible
consumption mode
Enable/Disable setting
consumption mode
Enable/Disable setting
Enable
PHT
1pixel halftone process
control correction
Enable/Disable setting
control correction
Enable/Disable setting
Normal
(Disable
: 1 : NO)
Reverse
(Enable :
0 : YES)
(Disable
: 1 : NO)
Reverse
(Enable :
0 : YES)
Disable
AR_AUTO
Auto registration
adjustment
Enable/Disable setting
adjustment
Enable/Disable setting
Enable
AR_ERROR
Auto registration
adjustment execution
error check
Enable/Disable setting
adjustment execution
error check
Enable/Disable setting
Enable
DM_PHASE
Drum phase fitting
Enable/Disable setting
Enable/Disable setting
Enable
SENSITIVITY
Toner density
correction
Enable/Disable setting
correction
Enable/Disable setting
Disable
PRT_HT
Halftone process
control printer
correction feedback
Enable/Disable setting
control printer
correction feedback
Enable/Disable setting
Enable
PTC_ENV
PTC environment
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
Enable:
Correc-
tion ON
Correc-
tion ON
PTC_LIFE
PTC life correction
Enable/Disable setting
Enable/Disable setting
Enable
Enable:
Correc-
tion ON
Correc-
tion ON
Item/Display
Content
Setting
range
Default
value
NOTE
HV
Normal operation high
density process control
Enable/Disable setting
density process control
Enable/Disable setting
Normal
(Disable:
1: NO)
Reverse
(Enable:
(Enable:
0: YES)
Enable
HT
Normal operation half
tone process control
Enable/Disable setting
tone process control
Enable/Disable setting
Enable
TC
Transfer output
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
MD VG
Membrane decrease
grid voltage correction
Enable/Disable setting
grid voltage correction
Enable/Disable setting
Enable
MD LD
Membrane laser power
voltage correction
Enable/Disable setting
voltage correction
Enable/Disable setting
Disable
MD EV
Membrane decrease
environment grid
voltage correction
Enable/Disable setting
environment grid
voltage correction
Enable/Disable setting
Enable
MD DL
Membrane decrease
discharge light quantity
correction
Enable/Disable setting
discharge light quantity
correction
Enable/Disable setting
Enable
MD DL EV
Membrane decrease
environment discharge
light quantity
correction
Enable/Disable setting
environment discharge
light quantity
correction
Enable/Disable setting
Disable
TN_HUM
Toner density humidity
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_AREA
Toner density area
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_LIFE
Toner density life
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_COV
Toner density print
ratio correction
Enable/Disable setting
ratio correction
Enable/Disable setting
Enable
TN_PROCON
Toner density process
control correction
Enable/Disable setting
control correction
Enable/Disable setting
Enable
Item/Display
Content
Setting
range
Default
value
NOTE
1
: ’11/Mar/15
1
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 46
44-2
Purpose
Adjustment/Setup
Function (Purpose) Used to adjust the sensitivity of the image
density sensor (registration sensor).
Section
Process
Operation/Procedure
Select [EXECUTE] button and press [OK] key (the adjustment is
executed automatically).
After completion of the adjustment, the adjustment result is dis-
played.
If the adjustment is not executed normally, "ERROR" is displayed.
• MX-C400P/C380P
Select [EXECUTE] button and press [OK] key (the adjustment is
executed automatically).
After completion of the adjustment, the adjustment result is dis-
played.
If the adjustment is not executed normally, "ERROR" is displayed.
• MX-C400P/C380P
• MX-B400P/B380P/B382P
TN_ENV
Toner density
environment correction
Enable/Disable setting
environment correction
Enable/Disable setting
Normal
(Disable:
1: NO)
Reverse
(Enable:
0: YES)
(Disable:
1: NO)
Reverse
(Enable:
0: YES)
Enable
TN_DRIP
Toner density
correction
unconditional supply
Enable/Disable setting
correction
unconditional supply
Enable/Disable setting
Enable
TN_SPEND
Toner forcible
consumption mode
Enable/Disable setting
consumption mode
Enable/Disable setting
Disable
SENSITIVITY
Toner density
correction
Enable/Disable setting
correction
Enable/Disable setting
Disable
PRT_HT
Half tone process
control printer
correction feedback
Enable/Disable setting
control printer
correction feedback
Enable/Disable setting
Enable
PTC_ENV
PTC environment
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
Enable:
Correc-
tion ON
Correc-
tion ON
PTC_LIFE
PTC life correction
Enable/Disable setting
Enable/Disable setting
Enable
Enable:
Correc-
tion ON
Correc-
tion ON
Item/Display
Content
Setting
range
Default
value
A
PCS_CL LED ADJ
Color sensor light
emitting quantity
adjustment value
emitting quantity
adjustment value
1 - 255
21
B
PCS_K LED ADJ
Black sensor light
emitting quantity
adjustment value
emitting quantity
adjustment value
1 - 255
21
C
PCS_CL DARK
Dark voltage of color
0 - 255
0
D
PCS_K DARK
Dark voltage of black
0 - 255
0
E
PCS_K GRND
Belt substrate when
the item B adjustment
is completed.
the item B adjustment
is completed.
0 - 255
0
F
PCS_K BELT MAX
Belt substrate input
max. value
max. value
0 - 255
0
G
PCS_K BELT MIN
Belt substrate input
min. value
min. value
0 - 255
0
H
PCS_K BELT DIF
Belt substrate input
difference
(Item F - Item G)
difference
(Item F - Item G)
0 - 255
0
I
REG_F LED ADJ
Registration sensor
light emitting quantity
adjustment value F
light emitting quantity
adjustment value F
1 - 255
32
J
REG_F DARK
Registration sensor
dark voltage F
dark voltage F
0 - 255
0
K
REG_F GRND
Belt substrate when
the item I adjustment
is completed.
the item I adjustment
is completed.
0 - 255
0
L
REG_R LED ADJ
Registration sensor
light emitting quantity
adjustment value R
light emitting quantity
adjustment value R
1 - 255
32
M
REG_R DARK
Registration sensor
dark voltage R
dark voltage R
0 - 255
0
Item/Display
Content
Setting
range
Default
value
NOTE
N
REG_R GRND
Belt substrate when
the item L adjustment
is completed.
the item L adjustment
is completed.
0 - 256
0
O
REG_F BELT MAX
Belt substrate input
max. value (F side)
max. value (F side)
0 - 255
0
P
REG_F BELT MIN
Belt substrate input
min. value (F side)
min. value (F side)
0 - 255
0
Q
REG_F BELT DIF
Belt substrate input
difference
(Item O - Item P)
difference
(Item O - Item P)
0 - 255
0
R
REG_R BELT MAX
Belt substrate input
max. value (R side)
max. value (R side)
0 - 255
0
S
REG_R BELT MIN
Belt substrate input
min. value (R side)
min. value (R side)
0 - 255
0
T
REG_R BELT DIF
Belt substrate input
difference
(Item R - Item S)
difference
(Item R - Item S)
0 - 255
0
U
REG_F PATCH (K)
Patch light receiving
potential F(K)
potential F(K)
0 - 255
0
V
REG_F PATCH (C)
Patch light receiving
potential F(C)
potential F(C)
0 - 255
0
W
REG_F PATCH (M)
Patch light receiving
potential F(M)
potential F(M)
0 - 255
0
X
REG_F PATCH (Y)
Patch light receiving
potential F(Y)
potential F(Y)
0 - 255
0
Y
REG_R PATCH (K)
Patch light receiving
potential R(K)
potential R(K)
0 - 255
0
Z
REG_R PATCH (C)
Patch light receiving
potential R(C)
potential R(C)
0 - 255
0
AA
REG_R PATCH (M)
Patch light receiving
potential R(M)
potential R(M)
0 - 255
0
AB
REG_R PATCH (Y)
Patch light receiving
potential R(Y)
potential R(Y)
0 - 255
0
Error name
Error content
Black sensor adjustment
abnormality
abnormality
PCS_K LED ADJ error
The target is not reached by 3 times of retry.
The target is not reached by 3 times of retry.
Color sensor adjustment
abnormality
abnormality
PCS_CL LED ADJ error
The target is not reached by 3 times of retry.
The target is not reached by 3 times of retry.
Substrate scan
abnormality
abnormality
PCS_K GRND error
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Registration sensor F
adjustment abnormality
adjustment abnormality
REG_F LED ADJ error
The target is not reached by 3 times of retry.
The target is not reached by 3 times of retry.
Registration sensor R
adjustment abnormality
adjustment abnormality
REG_R LED ADJ error
The target is not reached by 3 times of retry.
The target is not reached by 3 times of retry.
Registration substrate F
scan abnormality
scan abnormality
REG_F GRND error
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Registration substrate R
scan abnormality
scan abnormality
REG_R GRND error
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Effective difference between the upper and
lower values of the belt substrate circuit,
outside the range
Display/Item
Content
Range
Default
A
PCS_K LED ADJ
Image density sensor light
emitting quantity
adjustment value
emitting quantity
adjustment value
1 - 255
32
B
PCS_K DARK
Dark voltage
0 - 255
0
C
PCS_K GRND
Belt base detection level
when completion of Item A
adjustment
when completion of Item A
adjustment
0 - 255
0
D
PCS_K BELT MAX
Maximum value of belt
base detection level
base detection level
0 - 255
0
E
PCS_K BELT MIN
Minimum value of belt
base detection level
base detection level
0 - 255
0
F
PCS_K BELT DIF
Belt base detection level
difference
(Item D - Item E)
difference
(Item D - Item E)
0 - 255
0
Item/Display
Content
Setting
range
Default
value
1
: ’11/Mar/15
1
Click on the first or last page to see other MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) service manuals if exist.