MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 35
*1: 1 Count = 1sec Change
• MX-B400P/B380P
Z
HL_E E-STAR LL
Preheating TH_E set value
1 - 99
55
AA
HL_UM PRE-JOB LL 
Resetting from preheating TH_UM set value (Job Ready temperature)
1 - 99
55
AB
HL_LM E-STAR LL
Preheating TH_LM set value
1 - 99
55
AC
HL_UM WARMUP_120L LL
Warm-up TH_UM set value (when the fusing temperature is 120
C or less)
1 - 99
55
AD
HL_LM WARMUP_120L LL
Warm-up TH_LM set value (when the fusing temperature is 120
C or less)
1 - 99
55
AE
HL_E WARMUP_120L LL
Warm-up TH_E set value (when the fusing temperature is 120
C or less)
1 - 99
50
AF
LO_WARMUP_TIME LL
AC - AE applying time (Time (sec) for shifting from the control temperature in 
warm-up to the normal control temperature)
1 - 99
50
AG
HL_UM WARMUP_120H LL
Warm-up TH_UM set value (when the fusing temperature is 120
C or above)
1 - 99
55
AH
HL_LM WARMUP_120H LL
Warm-up TH_LM set value (when the fusing temperature is 120
C or above)
1 - 99
55
AI
HL_E WARMUP_120H LL
Warm-up TH_E set value (when the fusing temperature is 120
C or above)
1 - 99
50
AJ
HI_WARMUP_TIME LL
AG - AI applying time (Timer from completion of Ready)
1 - 99
50
AK
HI_WU_FM_ON_TMP LL
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
45
AL 
(*1)
HI_WU_END_TIME LL
Warm-up complete time (sec) (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AM
HI_WU_JOB_SET_TMP LL
Job Ready TH_UM temperature (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
55
AN
HI_WARMUP_BORDER LL
Threshold value applied to Sim43-1-AK - AM
1 - 99
50
AO
LO_WU_JOB_SET_TMP LL
TH_UM temperature to enable a job during warming up (when the fusing 
temperature in warming up is alpha 
C or below.)
1 - 99
55
AP 
(*1)
JOBEND_FUMON_TIME LL
Fusing roller rotation time (sec) after completion of a job
1 - 99
50
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
A
HL_UM READY LL
Ready standby TH_UM set value
1 - 99
55
55
55
B
HL_LM READY LL
Ready standby TH_LM set value
1 - 99
55
55
55
C
HL_E READY LL
Ready standby TH_E set value
1 - 99
55
55
55
D
HL_UM PLAIN PAPER BW LL
Plain paper TH_UM set value
1 - 99
55
55
55
E
HL_LM PLAIN PAPER BW LL
Plain paper TH_LM set value
1 - 99
55
55
55
F
HL_E PLAIN PAPER BW LL
Plain paper TH_E set value
1 - 99
55
55
55
G
WARMUP FUMON HL_E T LL
Fusing motor pre-rotation start TH_E set value
1 - 99
45
H
WARMUP FUMOFF LL
Fusing motor pre-rotation end time TH_LM set value
1 - 99
50
(*1)
WARMUP END TIME LL
Warm-up complete time (warm-up time (sec))
1 - 99
80
J
HL_UM HEAVY PAPER LL
Heavy paper TH_UM set value
1 - 99
55
K
HL_LM HEAVY PAPER LL
Heavy paper TH_LM set value
1 - 99
55
L
HL_E HEAVY PAPER LL
Heavy paper TH_E set value
1 - 99
50
M
HL_UM OHP PAPER LL
OHP-TH_UM set value
1 - 99
55
N
HL_LM OHP PAPER LL
OHP-TH_LM set value
1 - 99
55
O
HL_E OHP PAPER LL
OHP-TH_E set value
1 - 99
50
P
HL_UM ENV PAPER LL
Envelope TH_UM set value
1 - 99
55
Q
HL_LM ENV PAPER LL
Envelope TH_LM set value
1 - 99
55
R
HL_E ENV PAPER LL
Envelope TH_E set value
1 - 99
50
S
HL_UM GLOSS PAPER LL
Glossy paper TH_UM set value
1 - 99
55
T
HL_LM GLOSS PAPER LL
Glossy paper TH_LM set value
1 - 99
55
U
HL_E GLOSS PAPER LL
Glossy paper TH_E set value
1 - 99
50
V
HL_UM E-STAR LL
Preheating TH_UM set value
1 - 99
55
W
HL_E E-STAR LL
Preheating TH_E set value
1 - 99
55
X
HL_UM PRE-JOB LL 
Resetting from preheating TH_UM set value (Job Ready temperature)
1 - 99
55
Y
HL_LM E-STAR LL
Preheating TH_LM set value
1 - 99
55
Z
HL_UM WARMUP_120L LL
Warm-up TH_UM set value (when the fusing temperature is 120
C or less)
1 - 99
55
AA
HL_LM WARMUP_120L LL
Warm-up TH_LM set value (when the fusing temperature is 120
C or less)
1 - 99
55
AB
HL_E WARMUP_120L LL
Warm-up TH_E set value (when the fusing temperature is 120
C or less)
1 - 99
50
AC
LO_WARMUP_TIME LL
Z - AB applying time (Time (sec) for shifting from the control temperature in warm-
up to the normal control temperature)
1 - 99
50
AD
HL_UM WARMUP_120H LL
Warm-up TH_UM set value (when the fusing temperature is 120
C or above)
1 - 99
55
AE
HL_LM WARMUP_120H LL
Warm-up TH_LM set value (when the fusing temperature is 120
C or above)
1 - 99
55
AF
HL_E WARMUP_120H LL
Warm-up TH_E set value (when the fusing temperature is 120
C or above)
1 - 99
50
AG
HI_WARMUP_TIME LL
AD - AF applying time (Timer from completion of Ready)
1 - 99
50
AH
HI_WU_FM_ON_TMP LL
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is alpha 
C or above)
1 - 99
45
AI 
(*1)
HI_WU_END_TIME LL
Warm-up complete time (sec) (when the fusing temperature in warm-up is alpha 
C or above)
1 - 99
50
AJ
HI_WU_JOB_SET_TMP LL
Job Ready TH_UM temperature (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
55
AK
HI_WARMUP_BORDER LL
Threshold value applied to Sim43-1-AH - AJ
1 - 99
50
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 36
: ’11/Mar/15
1
*1: 1 Count = 1sec Change
<Code descriptions>
• MX-B382P
*1: 1 Count = 1sec Change
AL
LO_WU_JOB_SET_TMP LL
TH_UM temperature to enable a job during warming up 
(when the fusing temperature in warming up is alpha 
C or below.)
1 - 99
55
AM 
(*1)
JOBEND_FUMON_TIME LL
Fusing roller rotation time (sec) after completion of a job
1 - 99
50
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
1
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
A
HL_UM READY LL
Ready standby TH_UM set value
1 - 99
55
B
HL_LM READY LL
Ready standby TH_LM set value
1 - 99
55
C
HL_US READY LL
Ready standby TH_US set value
1 - 99
55
D
HL_UM PLAIN PAPER BW LL
Plain paper TH_UM set value
1 - 99
55
E
HL_LM PLAIN PAPER BW LL
Plain paper TH_LM set value
1 - 99
55
F
HL_US PLAIN PAPER BW LL
Plain paper TH_US set value
1 - 99
55
G
WARMUP FUMON HL_UM T LL
Fusing motor pre-rotation start TH_UM set value
1 - 99
45
H
WARMUP FUMOFF LL
Fusing motor pre-rotation end time
1-99
50
(*1)
WARMUP END TIME LL
Warm-up complete time (warm-up time (sec))
1 - 99
80
J
HL_UM HEAVY PAPER LL
Heavy paper TH_UM set value
1 - 99
55
K
HL_LM HEAVY PAPER LL
Heavy paper TH_LM set value
1 - 99
55
L
HL_US HEAVY PAPER LL
Heavy paper TH_US set value
1 - 99
50
M
HL_UM OHP PAPER LL
OHP-TH_UM set value
1 - 99
55
N
HL_LM OHP PAPER LL
OHP-TH_LM set value
1 - 99
55
O
HL_US OHP PAPER LL
OHP-TH_US set value
1 - 99
50
P
HL_UM ENV PAPER LL
Envelope TH_UM set value
1 - 99
55
Q
HL_LM ENV PAPER LL
Envelope TH_LM set value
1 - 99
55
R
HL_US ENV PAPER LL
Envelope TH_US set value
1 - 99
50
S
HL_UM GLOSS PAPER LL
Glossy paper TH_UM set value
1 - 99
55
T
HL_LM GLOSS PAPER LL
Glossy paper TH_LM set value
1 - 99
55
U
HL_US GLOSS PAPER LL
Glossy paper TH_US set value
1 - 99
55
V
HL_UM E-STAR LL
Preheating TH_UM set value
1 - 99
55
W
HL_US E-STAR LL
Preheating TH_US set value
1 - 99
55
X
HL_UM PRE-JOB LL 
Resetting from preheating TH_UM set value (Job Ready temperature)
1 - 99
55
Y
HL_LM E-STAR LL
Preheating TH_LM set value
1 - 99
55
Z
HL_UM WARMUP_120L LL
Warm-up TH_UM set value (when the fusing temperature is 120
C or less)
1 - 99
55
AA
HL_LM WARMUP_120L LL
Warm-up TH_LM set value (when the fusing temperature is 120
C or less)
1 - 99
55
AB
HL_US WARMUP_120L LL
Warm-up TH_US set value (when the fusing temperature is 120
C or less)
1 - 99
50
AC
LO_WARMUP_TIME LL
Z - AB applying time (Time (sec) for shifting from the control temperature in 
warm-up to the normal control temperature)
1 - 99
50
AD
HL_UM WARMUP_120H LL
Warm-up TH_UM set value (when the fusing temperature is 120
C or above)
1 - 99
55
AE
HL_LM WARMUP_120H LL
Warm-up TH_LM set value (when the fusing temperature is 120
C or above)
1 - 99
55
AF
HL_US WARMUP_120H LL
Warm-up TH_US set value (when the fusing temperature is 120
C or above)
1 - 99
50
AG
HI_WARMUP_TIME LL
AD - AF applying time (Timer from completion of Ready)
1 - 99
50
AH
HI_WU_FM_ON_TMP LL
Fusing roller rotation start TH_UM (when the fusing temperature in warm-up 
is alpha 
C or above)
1 - 99
45
AI 
(*1)
HI_WU_END_TIME LL
Warm-up complete time (sec) (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AJ
HI_WU_JOB_SET_TMP LL
Job Ready TH_UM temperature (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
55
AK
HI_WARMUP_BORDER LL
Threshold value applied to Sim43-1-AH - AJ
1 - 99
50
AL
LO_WU_JOB_SET_TMP LL
TH_UM temperature to enable a job during warming up (when the fusing 
temperature in warming up is alpha 
C or below.)
1 - 99
55
AM 
(*1)
JOBEND_FUMON_TIME LL
Fusing roller rotation time (sec) after completion of a job
1 - 99
50
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 37
: ’11/Mar/15
1
<Code descriptions>
 
43-21
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
Section
Operation/Procedure
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
Correction value: -49 - +49, 1 Count = 1
C Change
• MX-C400P/C380P
TH_UM
Fusing upper thermistor main
TH_LM
Fusing lower thermistor main
TH_US
Fusing upper thermistor sub
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_US
Heater lamp upper sub
1
Group
Destination
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
Correction value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
A
HL_UM READY HH
Ready standby TH_UM set value
1 - 99
50
50
50
B
HL_LM READY HH
Ready standby TH_LM set value
1 - 99
50
50
50
C
HL_E READY HH
Ready standby TH_E set value
1 - 99
50
50
50
D
HL_UM PLAIN PAPER BW HH
Black-White plain paper TH_UM set value
1 - 99
50
50
50
E
HL_LM PLAIN PAPER BW HH
Black-White plain paper TH_LM set value
1 - 99
50
50
50
F
HL_E PLAIN PAPER BW HH
Black-White plain paper TH_E set value
1 - 99
50
50
50
G
HL_UM PLAIN PAPER CL HH
Color plain paper TH_UM set value
1 - 99
50
50
50
H
HL_LM PLAIN PAPER CL HH
Color plain paper TH_LM set value
1 - 99
50
50
50
I
HL_E PLAIN PAPER CL HH
Color plain paper TH_E set value
1 - 99
50
50
50
J
WARMUP FUMON HL_E T HH
Fusing motor pre-rotation start TH_E set value
1 - 99
50
K
WARMUP FUMOFF HH
Fusing motor pre-rotation end time
1 - 99
50
(*1)
WARMUP END TIME HH
Warm-up complete time (warm-up time (sec))
1 - 99
50
M
HL_UM HEAVY PAPER HH
Heavy paper TH_UM set value
1 - 99
50
N
HL_LM HEAVY PAPER HH
Heavy paper TH_LM set value
1 - 99
50
O
HL_E HEAVY PAPER HH
Heavy paper TH_E set value
1 - 99
50
P
HL_UM OHP PAPER HH
OHP-TH_UM set value
1 - 99
50
Q
HL_LM OHP PAPER HH
OHP-TH_LM set value
1 - 99
50
R
HL_E OHP PAPER HH
OHP-TH_E set value
1 - 99
50
S
HL_UM ENV PAPER HH
Envelope TH_UM set value
1 - 99
50
T
HL_LM ENV PAPER HH
Envelope TH_LM set value
1 - 99
50
U
HL_E ENV PAPER HH
Envelope TH_E set value
1 - 99
50
V
HL_UM GLOSS PAPER HH
Glossy paper TH_UM set value
1 - 99
50
W
HL_LM GLOSS PAPER HH
Glossy paper TH_LM set value
1 - 99
50
X
HL_E GLOSS PAPER HH
Glossy paper TH_E set value
1 - 99
50
Y
HL_UM E-STAR HH
Preheating TH_UM set value
1 - 99
50
Z
HL_E E-STAR HH
Preheating TH_E set value
1 - 99
50
AA
HL_UM PRE-JOB HH 
Resetting from preheating TH_UM set value (Job Ready temperature)
1 - 99
50
AB
HL_LM E-STAR HH
Preheating TH_LM set value
1 - 99
50
AC
HL_UM WARMUP_120L HH
Warm-up TH_UM set value (when the fusing temperature is 120
C or less)
1 - 99
50
AD
HL_LM WARMUP_120L HH
Warm-up TH_LM set value (when the fusing temperature is 120
C or less)
1 - 99
50
AE
HL_E WARMUP_120L HH
Warm-up TH_E set value (when the fusing temperature is 120
C or less)
1 - 99
50
AF 
(*1)
LO_WARMUP_TIME HH
AC - AE applying time (Time (sec) for shifting from the control temperature in 
warm-up to the normal control temperature)
1 - 99
50
AG
HL_UM WARMUP_120H HH
Warm-up TH_UM set value (when the fusing temperature is 120
C or above)
1 - 99
50
AH
HL_LM WARMUP_120H HH
Warm-up TH_LM set value (when the fusing temperature is 120
C or above)
1 - 99
50
AI
HL_E WARMUP_120H HH
Warm-up TH_E set value (when the fusing temperature is 120
C or above)
1 - 99
50
AJ
HI_WARMUP_TIME HH
AG - AI applying time (Timer from completion of Ready)
1 - 99
50
AK
HI_WU_FM_ON_TMP HH
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AL 
(*1)
HI_WU_END_TIME HH
Warm-up complete time (sec) (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AM
HI_WU_JOB_SET_TMP HH
Job Ready TH_UM temperature (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AN
HI_WARMUP_BORDER HH
Threshold value applied to Sim43-1-AK - AM
1 - 99
50
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 38
*1: 1 Count = 1sec Change
• MX-B400P/B380P
*1: 1 Count = 1sec Change
<Code descriptions>
AO
LO_WU_JOB_SET_TMP HH
TH_UM temperature to enable a job during warming up (When the fusing 
temperature in warming up is alpha 
C or below.)
1 - 99
50
AP 
(*1)
JOBEND_FUMON_TIME HH
Fusing roller rotation time (sec) after completion of a job
1 - 99
50
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
A
HL_UM READY HH
Ready standby TH_UM set value
1 - 99
50
50
50
B
HL_LM READY HH
Ready standby TH_LM set value
1 - 99
50
50
50
C
HL_E READY HH
Ready standby TH_E set value
1 - 99
50
50
50
D
HL_UM PLAIN PAPER BW HH
Plain paper TH_UM set value
1 - 99
50
50
50
E
HL_LM PLAIN PAPER BW HH
Plain paper TH_LM set value
1 - 99
50
50
50
F
HL_E PLAIN PAPER BW HH
Plain paper TH_E set value
1 - 99
50
50
50
G
WARMUP FUMON HL_E T HH
Fusing motor pre-rotation start TH_E set value
1 - 99
50
H
WARMUP FUMOFF HH
Fusing motor pre-rotation end time TH_LM set value
1 - 99
50
(*1)
WARMUP END TIME HH
Warm-up complete time (warm-up time (sec))
1 - 99
50
J
HL_UM HEAVY PAPER HH
Heavy paper TH_UM set value
1 - 99
50
K
HL_LM HEAVY PAPER HH
Heavy paper TH_LM set value
1 - 99
50
L
HL_E HEAVY PAPER HH
Heavy paper TH_E set value
1 - 99
50
M
HL_UM OHP PAPER HH
OHP-TH_UM set value
1 - 99
50
N
HL_LM OHP PAPER HH
OHP-TH_LM set value
1 - 99
50
O
HL_E OHP PAPER HH
OHP-TH_E set value
1 - 99
50
P
HL_UM ENV PAPER HH
Envelope TH_UM set value
1 - 99
50
Q
HL_LM ENV PAPER HH
Envelope TH_LM set value
1 - 99
50
R
HL_E ENV PAPER HH
Envelope TH_E set value
1 - 99
50
S
HL_UM GLOSS PAPER HH
Glossy paper TH_UM set value
1 - 99
50
T
HL_LM GLOSS PAPER HH
Glossy paper TH_LM set value
1 - 99
50
U
HL_E GLOSS PAPER HH
Glossy paper TH_E set value
1 - 99
50
V
HL_UM E-STAR HH
Preheating TH_UM set value
1 - 99
50
W
HL_E E-STAR HH
Preheating TH_E set value
1 - 99
50
X
HL_UM PRE-JOB HH 
Resetting from preheating TH_UM set value (Job Ready temperature)
1 - 99
50
Y
HL_LM E-STAR HH
Preheating TH_LM set value
1 - 99
50
Z
HL_UM WARMUP_120L HH
Warm-up TH_UM set value (when the fusing temperature is 120
C or less)
1 - 99
50
AA
HL_LM WARMUP_120L HH
Warm-up TH_LM set value (when the fusing temperature is 120
C or less)
1 - 99
50
AB
HL_E WARMUP_120L HH
Warm-up TH_E set value (when the fusing temperature is 120
C or less)
1 - 99
50
AC 
(*1)
LO_WARMUP_TIME HH
Z - AB applying time (Time (sec) for shifting from the control temperature in 
warm-up to the normal control temperature)
1 - 99
50
AD
HL_UM WARMUP_120H HH
Warm-up TH_UM set value (when the fusing temperature is 120
C or above)
1 - 99
50
AE
HL_LM WARMUP_120H HH
Warm-up TH_LM set value (when the fusing temperature is 120
C or above)
1 - 99
50
AF
HL_E WARMUP_120H HH
Warm-up TH_E set value (when the fusing temperature is 120
C or above)
1 - 99
50
AG
HI_WARMUP_TIME HH
AD - AF applying time (Timer from completion of Ready)
1 - 99
50
AH
HI_WU_FM_ON_TMP HH
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AI 
(*1)
HI_WU_END_TIME HH
Warm-up complete time (sec) (when the fusing temperature in warm-up is alpha 
C or above)
1 - 99
50
AJ
HI_WU_JOB_SET_TMP HH
Job Ready TH_UM temperature (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AK
HI_WARMUP_BORDER HH
Threshold value applied to Sim43-1-AH - AJ
1 - 99
50
AL
LO_WU_JOB_SET_TMP HH
TH_UM temperature to enable a job during warming up 
(When the fusing temperature in warming up is alpha 
C or below.)
1 - 99
50
AM 
(*1)
JOBEND_FUMON_TIME HH
Fusing roller rotation time (sec) after completion of a job
1 - 99
50
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
Page of 127
Display

Click on the first or last page to see other MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) service manuals if exist.