Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual ▷ View online

MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 31
: ’11/Mar/15
1
<Code descriptions>
• MX-B382P
U
HL_E GLOSS PAPER
Glossy paper TH_E set value
70 - 230
220
V
HL_UM E-STAR
Preheating TH_UM set value
30 - 200
165
W
HL_E E-STAR
Preheating TH_E set value
30 - 200
165
X
HL_UM PRE-JOB
Resetting from preheating TH_UM set value (Job Ready 
temperature)
30 - 200
170
Y
HL_LM E-STAR
Preheating TH_LM set value
30 - 200
115
Z
HL_UM WARMUP_120L
Warm-up TH_UM set value (when the fusing temperature is 
120
C or less)
70 - 230
175
190
185
190
185
190
AA
HL_LM WARMUP_120L
Warm-up TH_LM set value (when the fusing temperature is 
120
C or less)
30 - 200
120
135
130
135
130
135
AB
HL_E WARMUP_120L
Warm-up TH_E set value (when the fusing temperature is 
120
C or less)
70 - 230
225
AC
LO_WARMUP_TIME
Z - AB applying time 
(Time for shifting from the ready state to the normal control 
temperature (sec))
0 - 255
5
AD
HL_UM WARMUP_120H
Warm-up TH_UM set value (when the fusing temperature is 
120
C or above)
70 - 230
175
190
185
190
185
190
AE
HL_LM WARMUP_120H
Warm-up TH_LM set value (when the fusing temperature is 
120
C or above)
30 - 200
120
135
130
135
130
135
AF
HL_E WARMUP_120H
Warm-up TH_E set value (when the fusing temperature is 
120
C or above)
70 - 230
220
225
225
225
225
225
AG
HI_WARMUP_TIME
AD - AF applying time (Timer from completion of Ready)
0 - 255
5
AH
HI_WU_FM_ON_TMP
TH_E temperature for FM to start rotation in warming up 
(when the fusing temperature in warm-up is alpha 
C or 
above)
30 - 200
130
AI
HI_WU_END_TIME
Warm-up complete time (sec) (when the fusing temperature 
in warm-up is alpha 
C or above)
0 - 255
40
AJ
HI_WU_JOB_SET_TMP
TH_UM temperature to enable a job during warming up 
(when the fusing temperature in warm-up is alpha 
C or 
above)
70 - 230
170
185
180
185
170
185
AK
HI_WARMUP_BORDER
Threshold value applied to Sim43-1-AH - AJ
1 - 119
70
AL
LO_WU_JOB_SET_TMP
TH_UM temperature to enable a job during warming up 
(When the fusing temperature in warming up is alpha 
C or 
below.)
70 - 230
175
195
185
195
180
195
AM
JOBEND_FUMON_TIME
Fusing roller rotation time (sec) after completion of a job
0 - 255
5
Item/Display
Content
Setting 
range
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
1
Item/Display
Content
Setting 
range
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY
Ready standby TH_UM set value
70 - 230
170
175
190
190
B
HL_LM READY
Ready standby TH_LM set value
30 - 200
120
135
130
135
130
135
C
HL_US READY
Ready standby TH_US set value
70 - 230
170
175
190
190
D
HL_UM PLAIN PAPER BW
Black-White plain paper TH_UM set value
70 - 230
170
175
190
190
E
HL_LM PLAIN PAPER BW
Black-White plain paper TH_LM set value
30 - 200
125
140
135
140
135
140
F
HL_US PLAIN PAPER BW
Black-White plain paper TH_US set value
70 - 230
170
175
190
190
G
WARMUP FUMON HL_UM T
Fusing motor pre-rotation start TH_UM set value
30 - 200
150
H
WARMUP FUMOFF
Fusing motor pre-rotation end time
0 - 255
30
I
WARM UP END TIME
Warm-up complete time (warm-up time (sec))
30 - 255
83
110
83
110
83
110
J
HL_UM HEAVY PAPER
Heavy paper TH_UM set value
70 - 230
165
K
HL_LM HEAVY PAPER
Heavy paper TH_LM set value
30 - 200
140
L
HL_US HEAVY PAPER
Heavy paper TH_US set value
70 - 230
165
M
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 230
150
N
HL_LM OHP PAPER
OHP-TH_LM set value
30 - 200
140
O
HL_US OHP PAPER
OHP-TH_US set value
70 - 230
150
P
HL_UM ENV PAPER
Envelope TH_UM set value
70 - 230
200
Q
HL_LM ENV PAPER
Envelope TH_LM set value
30 - 200
140
R
HL_US ENV PAPER
Envelope TH_US set value
70 - 230
200
S
HL_UM GLOSS PAPER
Glossy paper TH_UM set value
70 - 230
190
T
HL_LM GLOSS PAPER
Glossy paper TH_LM set value
30 - 200
140
U
HL_US GLOSS PAPER
Glossy paper TH_US set value
70 - 230
190
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 32
: ’11/Mar/15
1
<Code descriptions>
Destination link item (When the destination setting is changed with
SIM26-6, the set value is changed linking with the destination.)
SW-A Setting value when plain paper is selected in the system set-
ting/device setting/fusing control setting.
SW-B Set value when heavy paper is selected in the system set-
ting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on
plain paper or heavy paper which is selected in the system setting/
device setting/fusing control setting.
(Example) When plain paper is selected in the system setting/
device setting/fusing control setting, the value of SW-A is dis-
played. 
NOTE: When the destination is changed with SIM26-6 after chang-
ing this set value, the set values of the destination link
items are reset to the default. 
V
HL_UM E-STAR
Preheating TH_UM set value
30 - 200
120
W
HL_US E-STAR
Preheating TH_US set value
30 - 200
120
X
HL_UM PRE-JOB
Resetting from preheating TH_UM set value (Job Ready 
temperature)
30 - 200
170
Y
HL_LM E-STAR
Preheating TH_LM set value
30 - 200
115
Z
HL_UM WARMUP_120L
Warm-up TH_UM set value (when the fusing temperature 
is 120
C or less)
70 - 230
170
175
190
190
AA
HL_LM WARMUP_120L
Warm-up TH_LM set value (when the fusing temperature 
is 120
C or less)
30 - 200
120
135
130
135
130
135
AB
HL_US WARMUP_120L
Warm-up TH_US set value (when the fusing temperature 
is 120
C or less)
70 - 230
170
175
190
190
AC
LO_WARMUP_TIME
Z - AB applying time (Timer from completion of Ready)
0 - 255
5
AD
HL_UM WARMUP_120H
Warm-up TH_UM set value (when the fusing temperature 
is 120
C or above)
70 - 230
165
170
190
190
AE
HL_LM WARMUP_120H
Warm-up TH_LM set value (when the fusing temperature 
is 120
C or above)
30 - 200
120
135
130
135
130
135
AF
HL_US WARMUP_120H
Warm-up TH_US set value (when the fusing temperature 
is 120
C or above)
70 - 230
165
170
190
190
AG
HI_WARMUP_TIME
AD - AF applying time (Timer from completion of Ready)
0 - 255
5
AH
HI_WU_FM_ON_TMP
Fusing roller rotation start TH_UM (when the fusing 
temperature in warm-up is alpha 
C or above)
30 - 200
150
AI
HI_WU_END_TIME
Warm-up complete time (sec) (when the fusing 
temperature in warm-up is alpha 
C or above)
0 - 255
40
AJ
HI_WU_JOB_SET_TMP
Job Ready TH_UM temperature (when the fusing 
temperature in warm-up is alpha 
C or above)
70 - 230
170
175
190
190
AK
HI_WARMUP_BORDER
Threshold value applied to Sim43-1-AH - AJ
1 - 119
70
AL
LO_WU_JOB_SET_TMP
Warm-up complete time (sec) (When the fusing 
temperature in warming up is alpha 
C or below.)
70 - 230
170
175
190
190
AM
JOBEND_FUMON_TIME
Fusing roller rotation time (sec) after completion of a job
0 - 255
2
Item/Display
Content
Setting 
range
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
1
TH_UM
Fusing upper thermistor main
TH_LM
Fusing lower thermistor main
TH_US
Fusing upper thermistor sub
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_US
Heater lamp upper sub
Group
Destination
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 33
 
43-4
Purpose
Setting
Function (Purpose) Used to set the fusing temperature 2 in
each mode. (Continued from SIM 43-1.)
Section
Operation/Procedure
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
NOTE: The set value is the reference value, and it may differ from
the actual fusing temperature depending on the operating
conditions.
• MX-C400P/C380P
• MX-B400P/B380P
<Code descriptions>
Item/Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM PLAIN PAPER BW DUP
Black-White plain paper duplex TH_UM set value
70 - 230
175
190
185
190
185
190
B
HL_LM PLAIN PAPER BW DUP
Black-White plain paper duplex TH_LM set value
30 - 200
110
125
120
125
120
125
C
HL_E PLAIN PAPER BW DUP
Black-White plain paper duplex TH_E set value
70 - 230
220
220
220
220
220
220
D
PLAIN PAPER BW DUP APP CNT
Black-White plain paper duplex fusing temperature 
application start image screen number
0  -  60
0
0
0
0
0
0
E
HL_UM PLAIN PAPER CL DUP
Color plain paper duplex TH_UM set value
70 - 230
175
190
185
190
185
190
F
HL_LM PLAIN PAPER CL DUP
Color plain paper duplex TH_LM set value
30 - 200
110
125
120
125
120
125
G
HL_E PLAIN PAPER CL DUP
Color plain paper duplex TH_E set value
70 - 230
220
220
220
220
220
220
H
PLAIN PAPER CL DUP APP CNT
Color plain paper duplex fusing temperature 
application start image screen number
0  -  60
0
0
0
0
0
0
I
HL_UM HEAVY PAPER BW DUP
Black-White heavy paper duplex TH_UM set value
70 - 230
185
J
HL_LM HEAVY PAPER BW DUP
Black-White heavy paper duplex TH_LM set value
30 - 200
120
K
HL_E HEAVY PAPER BW DUP
Black-White heavy paper duplex TH_E set value
70 - 230
220
L
HEAVY PAPER BW DUP APP CNT
Black-White heavy paper duplex fusing 
temperature application start image screen 
number
0 - 60
1
M
HL_UM HEAVY PAPER CL DUP
Color heavy paper duplex TH_UM set value
70 - 230
185
N
HL_LM HEAVY PAPER CL DUP
Color heavy paper duplex TH_LM set value
30 - 200
120
O
HL_E HEAVY PAPER CL DUP
Color heavy paper duplex TH_E set value
70 - 230
220
P
HEAVY PAPER CL DUP APP CNT
Color heavy paper duplex fusing temperature 
application start image screen number
0 - 60
1
Item/Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM PLAIN PAPER BW DUP
Plain paper duplex TH_UM set value
70 - 230
175
190
185
190
185
190
B
HL_LM PLAIN PAPER BW DUP
Plain paper duplex TH_LM set value
30 - 200
110
125
120
125
120
125
C
HL_E PLAIN PAPER BW DUP
Plain paper duplex TH_E set value
70 - 230
220
220
220
220
220
220
D
PLAIN PAPER BW DUP APP CNT
Plain paper duplex fusing temperature application 
start image screen number
0  -  60
0
0
0
0
0
0
E
HL_UM HEAVY PAPER BW DUP
Heavy paper duplex TH_UM set value
70 - 230
185
F
HL_LM HEAVY PAPER BW DUP
Heavy paper duplex TH_LM set value
30 - 200
120
G
HL_E HEAVY PAPER BW DUP
Heavy paper duplex TH_E set value
70 - 230
220
H
HEAVY PAPER BW DUP APP CNT
Heavy paper duplex fusing temperature application 
start image screen number
0 - 60
1
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 34
: ’11/Mar/15
1
• MX-B382P
<Code descriptions>
 
43-20
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environmental correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-1) in each paper mode.
Section
Operation/Procedure
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
Correction value: -49 - +49, 1 Count = 1
C Change
• MX-C400P/C380P
1
Item/Display
Content
Setting 
range
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM PLAIN PAPER BW DUP
Plain paper duplex TH_UM set value
70 - 230
170
175
190
190
B
HL_LM PLAIN PAPER BW DUP
Plain paper duplex TH_LM set value
30 - 200
110
125
120
125
120
125
C
HL_US PLAIN PAPER BW DUP
Plain paper duplex TH_US set value
70 - 230
170
175
190
190
D
PLAIN PAPER BW DUP APP CNT
Plain paper duplex fusing temperature application 
start image screen number
0 - 60
0
E
HL_UM HEAVY PAPER BW DUP
Heavy paper duplex TH_UM set value
70 - 230
165
F
HL_LM HEAVY PAPER BW DUP
Heavy paper duplex TH_LM set value
30 - 200
120
G
HL_US HEAVY PAPER BW DUP
Heavy paper duplex TH_US set value
70 - 230
165
H
HEAVY PAPER BW DUP APP CNT
Heavy paper duplex fusing temperature 
application start image screen number
0 - 60
1
TH_UM
Fusing upper thermistor main
TH_LM
Fusing lower thermistor main
TH_US
Fusing upper thermistor sub
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_US
Heater lamp upper sub
Group
Destination
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
Correction value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
A
HL_UM READY LL
Ready standby TH_UM set value
1 - 99
55
55
55
B
HL_LM READY LL
Ready standby TH_LM set value
1 - 99
55
55
55
C
HL_E READY LL
Ready standby TH_E set value
1 - 99
55
55
55
D
HL_UM PLAIN PAPER BW LL
Black-White plain paper TH_UM set value
1 - 99
55
55
55
E
HL_LM PLAIN PAPER BW LL
Black-White plain paper TH_LM set value
1 - 99
55
55
55
F
HL_E PLAIN PAPER BW LL
Black-White plain paper TH_E set value
1 - 99
55
55
55
G
HL_UM PLAIN PAPER CL LL
Color plain paper TH_UM set value
1 - 99
55
55
55
H
HL_LM PLAIN PAPER CL LL
Color plain paper TH_LM set value
1 - 99
55
55
55
I
HL_E PLAIN PAPER CL LL
Color plain paper TH_E set value
1 - 99
55
55
55
J
WARMUP FUMON HL_E T LL
Fusing motor pre-rotation start TH_E set value
1 - 99
45
K
WARMUP FUMOFF LL
Fusing motor pre-rotation end time
1 - 99
50
(*1)
WARMUP END TIME LL
Warm-up complete time (warm-up time (sec))
1 - 99
80
M
HL_UM HEAVY PAPER LL
Heavy paper TH_UM set value
1 - 99
55
N
HL_LM HEAVY PAPER LL
Heavy paper TH_LM set value
1 - 99
55
O
HL_E HEAVY PAPER LL
Heavy paper TH_E set value
1 - 99
50
P
HL_UM OHP PAPER LL
OHP-TH_UM set value
1 - 99
55
Q
HL_LM OHP PAPER LL
OHP-TH_LM set value
1 - 99
55
R
HL_E OHP PAPER LL
OHP-TH_E set value
1 - 99
50
S
HL_UM ENV PAPER LL
Envelope TH_UM set value
1 - 99
55
T
HL_LM ENV PAPER LL
Envelope TH_LM set value
1 - 99
55
U
HL_E ENV PAPER LL
Envelope TH_E set value
1 - 99
50
V
HL_UM GLOSS PAPER LL
Glossy paper TH_UM set value
1 - 99
55
W
HL_LM GLOSS PAPER LL
Glossy paper TH_LM set value
1 - 99
55
X
HL_E GLOSS PAPER LL
Glossy paper TH_E set value
1 - 99
50
Y
HL_UM E-STAR LL
Preheating TH_UM set value
1 - 99
55