Sharp Electronics (UK) Ltd., Technical Services Group
* Regarding the "ROM UPGRADE ... (11)" announced in T/R No. CCE1021 issued on
May 16th 2012, the descriptions were missing in the item of change, and No.2 and No.3
have been added.
1. Model Name:
MX-C310/C311/C380/C381/C400/C401, DX-C310/C311/C381/C400/C401
2. Description:
Upgrade of ICU-ROM
From mid-April 2012 production
Model Name
ROM control No.
ICU
PCU
SCU
IMAGE DATA E-Manual
MX-C311/C381/C401
DX-C311/C381/C401
DX-C311/C381/C401
E01
0402F1
0110F0
0102F0
0100F0
0160F1
MX-C310/C380/C400
DX-C310/C400
DX-C310/C400
E00
0402F0
0110F0
0102F0
0100F0
0160F1
* ICU above is the version described in the ROM management label.
Check that the actual version is as below (SIM22-5)
- MX-C311/C381/C401/DX-C381
ICU(MAIN): 04.02.F1/ICU(BOOT): 01.04.F1/LANGUAGE:01.17.F0/GRAPHIC: 01.02.F1/
COLOR_PROFILE: 01.00.F0
- MX-C310/C380/DX-C310
ICU(MAIN): 04.02.F0/ICU(BOOT): 01.03.F1/LANGUAGE:01.17.F0/GRAPHIC: 01.02.F1/
COLOR_PROFILE: 01.00.F0
Check that the actual version is as below (SIM22-5)
- MX-C311/C381/C401/DX-C381
ICU(MAIN): 04.02.F1/ICU(BOOT): 01.04.F1/LANGUAGE:01.17.F0/GRAPHIC: 01.02.F1/
COLOR_PROFILE: 01.00.F0
- MX-C310/C380/DX-C310
ICU(MAIN): 04.02.F0/ICU(BOOT): 01.03.F1/LANGUAGE:01.17.F0/GRAPHIC: 01.02.F1/
COLOR_PROFILE: 01.00.F0
Item of change :
1. When broadcasting to the large number of the destinations, the time from when the Start
button was pressed to when the original was started to be read out would become slower.
This problem has been corrected.
2. The following problem that was caused when 2.5-inch HDD was installed has been
corrected:
When starting the machine, it hanged up with the "Please wait" displayed (only with Data
Security Kit installed).
3. Firmware version upgrade has been made to support the change of the manufacturer of
8.5" LCD.
button was pressed to when the original was started to be read out would become slower.
This problem has been corrected.
2. The following problem that was caused when 2.5-inch HDD was installed has been
corrected:
When starting the machine, it hanged up with the "Please wait" displayed (only with Data
Security Kit installed).
3. Firmware version upgrade has been made to support the change of the manufacturer of
8.5" LCD.
ROM UPGRADE ..... (11).
TECHNICAL BULLETIN
Date: July 2012
Model: MX-
C310/C311/C380/C381/C400/C401,
DX-C310/C311/C381/C400/C401
Ref.: CCE1021
Model: MX-
C310/C311/C380/C381/C400/C401,
DX-C310/C311/C381/C400/C401
Ref.: CCE1021
Colour:
White
Page:
1 of 2
Sharp Electronics (UK) Ltd., Technical Services Group
ROM version combination history table
No.
ROM
control No.
ICU
PCU
SCU
IMAGE
DATA
E-Manual
Action
T/R No.
(10)
E00
0400F1
0110F0
0102F0
0100F0
0160F1
2011/11 Mid
CCE-990
(9)
D04
0303F1
0110F0
0102F0
0100F0
0160F1
2010/10
CCE-831
(8)
D03
0303F1
0109F0
0102F0
0100F0
0160F1
2010/7
CCE-800
(7)
D02
0301F1
0109F0
0102F0
0100F0
0160F1
2010/3
CCE-767
(6)
D01
0300F1
0108F0
0102F0
0100F0
0160F1
2009/12
2010/1
CCE-748
D00
0300F1
0107F0
0102F0
0100F0
0160F1
2009/12
(5)
C11
0220F1
0107F0
0102F0
0100F0
0160F1
2009/7 Mid
CCE-700
(4)
C00
0220F1
0106F0
0102F0
0100F0
0150F1
2009/7
(3)
B22
0103F1
0104F0
0101F0
0100F0
0140F1
2009/3 Mid
CCE-659
(2)
B12
0103F1
0104F0
0101F0
0100F0
0130F1
2009/1 Mid
(1)
B11
0103F1
0103F0
0101F0
0100F0
0130F1
2008/11 Mid
CCE-637
Display