DOWNLOAD Sharp MX-5500N / MX-6200N / MX-7000N (serv.man25) Service Manual ↓ Size: 2.87 MB | Pages: 99 in PDF or view online for FREE

Model
MX-5500N MX-6200N MX-7000N (serv.man25)
Pages
99
Size
2.87 MB
Type
PDF
Document
Peripheral
Brand
Device
Copying Equipment / MX- PEX2 SERVICE MANUAL
File
mx-5500n-mx-6200n-mx-7000n-sm25.pdf
Date

Sharp MX-5500N / MX-6200N / MX-7000N (serv.man25) Peripheral ▷ View online

69
Preliminary on-site checkout
Inspecting the system
If checking external and internal connections does not fix the problem, consider 
inspecting the system component by component (see Table A) and verifying that each 
hardware component is properly installed and configured before you decide to replace 
costly components. 
If a component in the system you are servicing does not meet a condition listed in 
Table A, and it is not clear how to fix the problem (for example, if the system hangs 
before reaching Idle), locate the behavior in Table B on page 73 to see the suggested 
action(s) for solving the problem. 
T
ABLE
 A
Verifying the system
Conditions to verify
Part and additional page references
• All replaceable parts are: 
• Present
• Properly aligned
• Installed securely
• Installed on the appropriate site
• The correct part for the system 
• Not visibly damaged
• Pan and contents have not been tampered with 
(no unauthorized additions or changes have been made)
• Pan does not contain any foreign objects
Fiery X3eTY2 pan, page 8
• Motherboard, including components and traces, appears 
undamaged and no foreign objects are evident
• CPU is present, well-seated in its motherboard connector, 
and appears undamaged
• CPU cooling unit is well-aligned and firmly attached
• Exhaust fan (including fan cable) is well-positioned (with correct 
airflow direction), installed in the correct connector, and appears 
undamaged
• Battery is installed
Motherboard, page 19
• Each DIMM is well-seated and installed in the correct slot
• DIMM connectors are not oxidized (reseating removes oxidation)
DIMM, page 16
70
Preliminary on-site checkout
Interface board is:
• Present
• Equipped with a security chip (chip is securely installed 
in socket U2 on the board)
• Installed in the slot PCI1 on the motherboard
• Well-seated
• Not visibly damaged
Interface board, page 13
CPU is:
• Present
• Well-seated in the motherboard socket
• Not visibly damaged
CPU cooling assembly is:
• Well-positioned (fan cable is able to reach fan 
connector on motherboard)
• Firmly attached
CPU and CPU cooling assembly, 
page 24 and page 29
Fan is:
• Properly positioned (with correct airflow direction)
• Installed in the correct fan cable connector on 
the motherboard
• Not visibly damaged (fan, fan cable, cable connector, 
and motherboard connector)
Exhaust fan, page 32
T
ABLE
 A
Verifying the system
Conditions to verify
Part and additional page references
71
Preliminary on-site checkout
Power supply is:
• Present
• Correctly installed
• Not visibly damaged
Cable connectors are:
• Firmly connected
• Not visibly damaged
• Installed in the correct devices and the correct leads on the power 
switch
Power supply, page 33
HDD is:
• Present
• Correctly installed
• Not visibly damaged
HDD data cable is:
• Present
• Firmly connected in the motherboard’s SATA1 connector
• Firmly connected to the HDD
• Not visibly damaged
HDD power cable is:
• Present
• SATA type. For more information, see page 41.
• Firmly connected to the power connector on the HDD
• Not visibly damaged
HDD, page 37
T
ABLE
 A
Verifying the system
Conditions to verify
Part and additional page references
72
Error codes and conditions
Error codes and conditions
To learn possible causes and solutions for a specific LED diagnostic code or error 
condition, find the symptom in Table B and perform the appropriate suggested actions 
in the order listed. If the problem persists after you perform a suggested action, proceed 
to the action described in the next numbered step. For example, in the steps:
1.
Check and reseat the MFP interface cable between the Fiery X3eTY2 and the MFP.
2.
Replace the MFP interface cable.
First perform the action in step 1. If the problem persists, proceed to the action described 
in step 2.
For detailed information about performing a suggested action, see the corresponding 
service section in this guide.
If replacing a specified component does not correct the problem, install the old 
component back in the Fiery X3eTY2. 
Page of 99
Display

Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man25) service manuals if exist.