77
Error codes and conditions
Startup (continued)
Fiery X3eTY2 starts up 
until FF appears on the 
LED display, then shuts 
down
One of the following:
• MFP is powered off
• Fiery X3eTY2 is powered off
• Faulty connection between 
the Fiery X3eTY2 and the MFP
• Faulty power supply
• Faulty motherboard
• Faulty CPU
• Faulty interface board
1. Make sure both the MFP power switch and the 
Fiery X3eTY2 power switch are in ON position.
2. Check and reseat the MFP interface cable between the 
Fiery X3eTY2 and the MFP.
3. Replace the MFP interface cable.
4. Listen for the power supply fan and feel for air near the 
Fiery X3eTY2 power switch where the power supply is 
located.
If you do not feel air from the power supply fan, you may 
have a faulty power supply which you must replace.
5. Clear the CMOS and power-up settings (see page 89).
6. Replace the motherboard.
7. Replace the CPU.
8. Replace the interface board.
T
ABLE
 B
Fiery X3eTY2 error codes and conditions (Continued)
Symptom
Possible cause
Suggested action 
78
Error codes and conditions
System problems
Clock is slow; time listed 
on Configuration page is 
earlier or later than the 
actual time
One of the following:
• Missing or dead battery 
on the motherboard
• Faulty motherboard
1. Replace the battery on the motherboard and then update 
the time in Fiery X3eTY2 Setup.
For information about Fiery X3eTY2 Setup, see 
Configuration and Setup on the User Documentation CD.
2. Clear the CMOS and power-up settings (see page 89).
3. Replace the motherboard.
System performs slowly 
or hangs periodically
One of the following:
• Missing or faulty DIMM(s), 
DIMM installed in wrong slot, 
or faulty DIMM connections
• Faulty HDD
• Overheated or faulty CPU
• Faulty motherboard
1. Check that each DIMM is installed in the correct slot 
(see page 17).
2. Check for missing DIMMs and reseat the DIMMs to 
remove any oxidation on the connectors.
3. If two DIMMs are installed, determine if a DIMM is 
at fault:
Remove the DIMM currently installed in socket 
DIMM1, and reboot the system. Reboot again with the 
other DIMM installed in DIMM2. If the problem is 
solved by one of the DIMMs, replace the other DIMM.
If the problem persists for both DIMMs, proceed to the 
next step.
4. Reseat the power and data cables to the HDD.
5. Replace the HDD data cable.
6. Replace the HDD.
7. Make sure that CPU on the motherboard is present and 
firmly seated and that the fan cable is connected. 
8. Replace the CPU.
9. Clear the CMOS and power-up settings (see page 89).
10. Replace the motherboard.
Chassis fan is noisy, 
or is not producing air
Fan is faulty
Replace the chassis fan.
T
ABLE
 B
Fiery X3eTY2 error codes and conditions (Continued)
Symptom
Possible cause
Suggested action 
79
Error codes and conditions
System software installation
USB flash drive method:
Fiery X3eTY2 remains on 
for 30 minutes (or longer) 
after beginning 
installation
One of the following:
• Fiery X3eTY2 is still connected to 
the MFP, and the MFP is powered 
on
• Service switches are set to 
Service mode
• Faulty HDD
• Faulty motherboard
• Faulty USB flash drive
1. Make sure that the MFP is powered off and that all cables 
between the Fiery X3eTY2 and the MFP are disconnected.
2. Make sure that the Fiery X3eTY2 service switches are set 
to Normal mode (away from “ON”).
If the service switches are in Service mode (toward 
“ON”), power off the Fiery X3eTY2, set the switches to 
Normal mode, power on, and allow the installation to 
resume.
3. Check the LED on the USB flash drive.
If the LED is not blinking (remains off or solid), the flash 
drive may be improperly seated. Power off the 
Fiery X3eTY2 and reseat the flash drive; then power on 
and allow the installation to resume.
4. Reseat the power and data cables to the HDD.
5. Replace the HDD data cable.
6. Replace the HDD.
7. Clear the CMOS and power-up settings (see page 89).
8. Replace the motherboard.
9. Replace the CPU.
10. Retry the installation using a different USB flash drive.
USB flash drive method:
During installation, the 
LED on the flash drive 
remains off or solid (not 
blinking)
One of the following:
• Faulty or improperly seated USB 
flash drive
• Faulty motherboard
• Faulty HDD
1. Power off the Fiery X3eTY2 and reseat the flash drive; then 
power on and allow the installation to resume.
2. Retry the installation using a different USB flash drive.
3. Clear the CMOS and power-up settings (see page 89).
4. Replace the motherboard.
5. Reseat the power and data cables to the HDD.
6. Replace the HDD data cable.
7. Replace the HDD.
T
ABLE
 B
Fiery X3eTY2 error codes and conditions (Continued)
Symptom
Possible cause
Suggested action 
80
Error codes and conditions
System software installation (continued)
Network port method:
Installation stalls for 
5 minutes (or longer) 
while downloading
“file 1 of x”
One of the following:
• Service switches are set to 
Normal mode
• Wrong or faulty Ethernet cable
• Faulty motherboard
1. Make sure that the Fiery X3eTY2 service switches are set 
to Service mode (toward “ON”).
If the service switches are in Normal mode (away from 
“ON”), click Cancel on the installer screen. Power off the 
Fiery X3eTY2, set the service switches to Service mode, 
and click Finish on the installer screen. Then retry the 
installation.
2. Make sure you are using a crossover Ethernet cable.
The MFP Ethernet cable is a crossover type, and may be 
used for the installation. For information about how to 
identify a crossover cable, see Figure Y on page 48.
If the cable appears damaged, replace it.
3. Clear the CMOS and power-up settings (see page 89).
4. Replace the motherboard.
Network port method:
Installation stalls for 
20 minutes (or longer) 
while downloading
any file higher than file 1.
One of the following:
• Faulty HDD
• Faulty motherboard
1. Reseat the power and data cables to the HDD.
2. Replace the HDD data cable.
3. Replace the HDD.
4. Clear the CMOS and power-up settings (see page 89).
5. Replace the motherboard.
T
ABLE
 B
Fiery X3eTY2 error codes and conditions (Continued)
Symptom
Possible cause
Suggested action 
Page of 99
Display