Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ▷ View online
AR-M350 SIMULATIONS 10-62
<List of set values>
66-4
Purpose
Operation test, check
Function (Content)
Used to check the operation of data signal output
in the FAX data output mode.
(Used to check the MODEM operation.)
Send level 0db (Max.)
(Only when FAX is installed.)
in the FAX data output mode.
(Used to check the MODEM operation.)
Send level 0db (Max.)
(Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure Signal output check (level Max.)
When CUSTOM SETTING is pressed during
execution of this simulation, execution is
stopped.
Enter a number and press START to change the
signal.
execution of this simulation, execution is
stopped.
Enter a number and press START to change the
signal.
SIMULATION 66-4
SIGNAL OUTPUT CHECK.(LEVEL MAX) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIGNAL OUTPUT CHECK.(LEVEL MAX) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
1
SIMULATION 66-4
SIGNAL OUTPUT CHECK.(LEVEL MAX) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIGNAL OUTPUT CHECK.(LEVEL MAX) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
1
SIMULATION 66-4
SIGNAL OUTPUT CHECK.(LEVEL MAX) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIGNAL OUTPUT CHECK.(LEVEL MAX) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
2
SIMULATION 66-4
SIGNAL OUTPUT CHECK.(LEVEL MAX) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIGNAL OUTPUT CHECK.(LEVEL MAX) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
2
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
Select 2 and press [START] key.
Same
display
1
No signal
17
12.0 V33
2
33.6 V34
18
14.4 V17
3
31.2 V34
19
12.0 V17
4
28.8 V34
20
9.6 V17
5
26.4 V34
21
7.2 V17
6
24.0 V34
22
9.6 V29
7
21.6 V34
23
7.2 V29
8
19.2 V34
24
4.8 V27t
9
16.8 V34
25
2.4 V27t
10
14.4 V34
26
0.3 FLG
11
12.0 V34
27
CED2100
12
9.6 V34
28
CNG1100
13
7.2 V34
29
0.3 V21
14
4.8 V34
30
ANSam
15
2.4 V34
31
RINGER
16
14.4 V33
32
No RBT
,+ !" #$%&'
AR-M350 SIMULATIONS 10-63
<List of set values>
<Set value>
66-5
Purpose
Operation test, check
Function (Content)
Used to check the operations of data signal
output in the FAX data output mode.
(Used to check the MODEM operation.)
Signals are sent in the send level set with the
soft switch. (Only when FAX is installed.)
output in the FAX data output mode.
(Used to check the MODEM operation.)
Signals are sent in the send level set with the
soft switch. (Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure Signal output check
(Send level is set with the soft SW.)
When CUSTOM SETTING is pressed during
execution of this simulation,
execution is stopped.
Enter a number and press START to change the
kind of signal.
When CUSTOM SETTING is pressed during
execution of this simulation,
execution is stopped.
Enter a number and press START to change the
kind of signal.
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
1
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
1
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
2
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
2
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
Select 2 and press [START] key.
Same
display
1
No signal
17
12.0 V33
2
33.6 V34
18
14.4 V17
3
31.2 V34
19
12.0 V17
4
28.8 V34
20
9.6 V17
5
26.4 V34
21
7.2 V17
6
24.0 V34
22
9.6 V29
7
21.6 V34
23
7.2 V29
8
19.2 V34
24
4.8 V27t
9
16.8 V34
25
2.4 V27t
10
14.4 V34
26
0.3 FLG
11
12.0 V34
27
CED2100
12
9.6 V34
28
CNG1100
13
7.2 V34
29
0.3 V21
14
4.8 V34
30
ANSam
15
2.4 V34
31
RINGER
16
14.4 V33
32
No RBT
66-6
Purpose
User data output, check (display, print)
Function (Content)
Used to print the confidential password.
(Used when the confidential password is
forgotten.) (Only when FAX is installed.)
(Used when the confidential password is
forgotten.) (Only when FAX is installed.)
Section
Fax
Item
Data
Operation/Procedure The confidential pass code is printed.
1) The currently selected data is displayed on
the side of menu.
2) The paper size is automatically selected by
the size stored in the image memory.
1
Print start
0
SIMULATION 66-6
PASS CODE PRINT OUT.EXECUTING...
1. PRINT START
PASS CODE PRINT OUT.EXECUTING...
1. PRINT START
Select 1 and
press [START] key.
press [START] key.
If there is no data to print,
return without printing.
return without printing.
After completion of printing
SIMULATION 66-6
PASS CODE PRINT OUT. PRESS START
1. PRINT START
PASS CODE PRINT OUT. PRESS START
1. PRINT START
, !" #$%&'
AR-M350 SIMULATIONS 10-64
<Set value>
<List of set values>
66-7
Purpose
User data output, check (display, print)
Function (Content)
Used to print the image memory data
(memory send, receive).
(Only when FAX is installed.
(memory send, receive).
(Only when FAX is installed.
Section
Fax
Item
Data
Operation/Procedure The content of image memory is printed.
The paper size is automatically selected with the
paper size stored in the image memory.
paper size stored in the image memory.
1
Print start
66-8
Purpose
Operation test, check
Function (Content)
Used to check the output operation of the FAX
sound signals.
(Sound output IC operation check)
Send level 0dB (Max.)
(Only when FAX is installed.)
sound signals.
(Sound output IC operation check)
Send level 0dB (Max.)
(Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure A voice message is outputted. (Level 0)
Enter a number during execution to change the
signal.
Press START to start sending a voice message.
Press CUSTOMSETTING to terminate.
signal.
Press START to start sending a voice message.
Press CUSTOMSETTING to terminate.
0
SIMULATION 66-7
IMAGE MEMORY PRINT OUT.EXECUTING...
1. PRINT START
IMAGE MEMORY PRINT OUT.EXECUTING...
1. PRINT START
SIMULATION 66-7
IMAGE MEMORY PRINT OUT.PRESS START.
1. PRINT START
IMAGE MEMORY PRINT OUT.PRESS START.
1. PRINT START
Select 1 and
press [START] key.
press [START] key.
After completion of printing
(When 1 is selected)
1
NONE
NONE
2
PAUSE
PAUSE
3
MESSAGE1
MESSAGE1
4
MESSAGE2
MESSAGE2
5
MESSAGE3
MESSAGE3
6
MESSAGE4
MESSAGE4
7
MESSAGE5
MESSAGE5
8
MESSAGE6
MESSAGE6
9
MESSAGE7
MESSAGE7
10
MESSAGE8
MESSAGE8
11
MESSAGE9
MESSAGE9
12
MESSAGE10
MESSAGE10
13
MESSAGE11
MESSAGE11
14
MESSAGE12
MESSAGE12
15
MESSAGE13
MESSAGE13
16
MESSAGE14
MESSAGE14
17
MESSAGE15
MESSAGE15
18
ALARM
ALARM
19
RINGER
RINGER
20
EXT.TEL.RINGER
EXT.TEL.RINGER
SIMULATION 66-8
MESSAGE OUTPUT CHECK.(LEVEL MAX) SELECT 1-20, AND PRESS
START.
1.NONE
MESSAGE OUTPUT CHECK.(LEVEL MAX) SELECT 1-20, AND PRESS
START.
1.NONE
2.PAUSE
3.MESSAGE1
4.MESSAGE2
5.MESSAGE3
6.MESSAGE4
7.MESSAGE5
8.MESSAGE6
9.MESSAGE7
10.MESSAGE8
11.MESSAGE9
12.MESSAGE10
13.MESSAGE11
14.MESSAGE12
15.MESSAGE13
16.MESSAGE14
17.MESSAGE15
18.ALARM
19.RINGER
20.EXT.TEL.RINGER
2
SIMULATION 66-8
MESSAGE OUTPUT CHECK.(LEVEL MAX) SELECT 1-20, AND PRESS
START.EXECUTING...
1.NONE
MESSAGE OUTPUT CHECK.(LEVEL MAX) SELECT 1-20, AND PRESS
START.EXECUTING...
1.NONE
2.PAUSE
3.MESSAGE1
4.MESSAGE2
5.MESSAGE3
6.MESSAGE4
7.MESSAGE5
8.MESSAGE6
9.MESSAGE7
10.MESSAGE8
11.MESSAGE9
12.MESSAGE10
13.MESSAGE11
14.MESSAGE12
15.MESSAGE13
16.MESSAGE14
17.MESSAGE15
18.ALARM
19.RINGER
20.EXT.TEL.RINGER
1
SIMULATION 66-8
MESSAGE OUTPUT CHECK.(LEVEL MAX) SELECT 1-20, AND PRESS
START.EXECUTING...
1.NONE
MESSAGE OUTPUT CHECK.(LEVEL MAX) SELECT 1-20, AND PRESS
START.EXECUTING...
1.NONE
2.PAUSE
3.MESSAGE1
4.MESSAGE2
5.MESSAGE3
6.MESSAGE4
7.MESSAGE5
8.MESSAGE6
9.MESSAGE7
10.MESSAGE8
11.MESSAGE9
12.MESSAGE10
13.MESSAGE11
14.MESSAGE12
15.MESSAGE13
16.MESSAGE14
17.MESSAGE15
18.ALARM
19.RINGER
20.EXT.TEL.RINGER
2
SIMULATION 66-8
MESSAGE OUTPUT CHECK.(LEVEL MAX) SELECT 1-20, AND PRESS
START.
1.NONE
MESSAGE OUTPUT CHECK.(LEVEL MAX) SELECT 1-20, AND PRESS
START.
1.NONE
2.PAUSE
3.MESSAGE1
4.MESSAGE2
5.MESSAGE3
6.MESSAGE4
7.MESSAGE5
8.MESSAGE6
9.MESSAGE7
10.MESSAGE8
11.MESSAGE9
12.MESSAGE10
13.MESSAGE11
14.MESSAGE12
15.MESSAGE13
16.MESSAGE14
17.MESSAGE15
18.ALARM
19.RINGER
20.EXT.TEL.RINGER
2
Press [CUSTOM SETTING] key.
Press [CUSTOM SETTING] key.
Select 2 and press [START] key.
Select 1 and press [START] key.
Same
display
, !" #$%&'
AR-M350 SIMULATIONS 10-65
<List of set values>
66-9
Purpose
Operation test, check
Function (Content)
Used to check the output operation of the FAX
sound signals.
(Sound output IC operation check)
(Only when FAX is installed.)
sound signals.
(Sound output IC operation check)
(Only when FAX is installed.)
Section
Fax
Item
Operation
Operation/Procedure A voice message is outputted.
(Send level is set with SW.)
Enter a number during execution to change the
signal.
Press START to start sending a voice message.
Press CUSTOMSETTING to terminate.
Enter a number during execution to change the
signal.
Press START to start sending a voice message.
Press CUSTOMSETTING to terminate.
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.
1.NONE
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.
1.NONE
2.PAUSE
3.MESSAGE1
4.MESSAGE2
5.MESSAGE3
6.MESSAGE4
7.MESSAGE5
8.MESSAGE6
9.MESSAGE7
10.MESSAGE8
11.MESSAGE9
12.MESSAGE10
13.MESSAGE11
14.MESSAGE12
15.MESSAGE13
16.MESSAGE14
17.MESSAGE15
18.ALARM
19.RINGER
20.EXT.TEL.RINGER
2
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.EXECUTING...
1.NONE
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.EXECUTING...
1.NONE
2.PAUSE
3.MESSAGE1
4.MESSAGE2
5.MESSAGE3
6.MESSAGE4
7.MESSAGE5
8.MESSAGE6
9.MESSAGE7
10.MESSAGE8
11.MESSAGE9
12.MESSAGE10
13.MESSAGE11
14.MESSAGE12
15.MESSAGE13
16.MESSAGE14
17.MESSAGE15
18.ALARM
19.RINGER
20.EXT.TEL.RINGER
1
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.EXECUTING...
1.NONE
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.EXECUTING...
1.NONE
2.PAUSE
3.MESSAGE1
4.MESSAGE2
5.MESSAGE3
6.MESSAGE4
7.MESSAGE5
8.MESSAGE6
9.MESSAGE7
10.MESSAGE8
11.MESSAGE9
12.MESSAGE10
13.MESSAGE11
14.MESSAGE12
15.MESSAGE13
16.MESSAGE14
17.MESSAGE15
18.ALARM
19.RINGER
20.EXT.TEL.RINGER
2
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.
1.NONE
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.
1.NONE
2.PAUSE
3.MESSAGE1
4.MESSAGE2
5.MESSAGE3
6.MESSAGE4
7.MESSAGE5
8.MESSAGE6
9.MESSAGE7
10.MESSAGE8
11.MESSAGE9
12.MESSAGE10
13.MESSAGE11
14.MESSAGE12
15.MESSAGE13
16.MESSAGE14
17.MESSAGE15
18.ALARM
19.RINGER
20.EXT.TEL.RINGER
2
Press [CUSTOM SETTING] key.
Press [CUSTOM SETTING] key.
Select 2 and press [START] key.
Select 1 and press [START] key.
Same
display
1
NONE
NONE
2
PAUSE
PAUSE
3
MESSAGE1
MESSAGE1
4
MESSAGE2
MESSAGE2
5
MESSAGE3
MESSAGE3
6
MESSAGE4
MESSAGE4
7
MESSAGE5
MESSAGE5
8
MESSAGE6
MESSAGE6
9
MESSAGE7
MESSAGE7
10
MESSAGE8
MESSAGE8
11
MESSAGE9
MESSAGE9
12
MESSAGE10
MESSAGE10
13
MESSAGE11
MESSAGE11
14
MESSAGE12
MESSAGE12
15
MESSAGE13
MESSAGE13
16
MESSAGE14
MESSAGE14
17
MESSAGE15
MESSAGE15
18
ALARM
ALARM
19
RINGER
RINGER
20
EXT.TEL.RINGER
EXT.TEL.RINGER
66-10
Purpose
User data output, check (display, print)
Function (Content)
Used to clear all data of image memory
(memory send, receive). Confidential data is
also cleared. (Only when FAX is installed.)
(memory send, receive). Confidential data is
also cleared. (Only when FAX is installed.)
Section
Fax
Item
Data
Operation/Procedure The FAX image memory is cleared.
1) Select an item with 10 digit key pad and press
START. The following is executed and the
display returns to the initial state.
display returns to the initial state.
1: Image memory clear 2: Not clear
2) After completion of memory clear, reset.
SIMULATION 66-10
IMAGE MEMORY CLEAR.
ARE YOU SURE ?
1. YES
2. NO
IMAGE MEMORY CLEAR.
ARE YOU SURE ?
1. YES
2. NO
1
,* !" #$%&'