DOWNLOAD Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ↓ Size: 7.51 MB | Pages: 112 in PDF or view online for FREE

Model
AR-M35 AR-M450 (serv.man12)
Pages
112
Size
7.51 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual Section 2 - Disassembly, Machine Operation, Adjustments, Simulations, Trouble Codes
File
ar-m35-ar-m450-sm12.pdf
Date

Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ▷ View online

AR-M350 SIMULATIONS 10-70
<This mode is for development, and inhibited in the market.>
<This mode is for development, and inhibited in the market.>
<This mode is for development, and inhibited in the market.>
<This mode is for development, and inhibited in the market.>
66-23
Purpose
Operation test, check
Function (Content)
Used to download the FAX program. 
(Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure The contents of ROM in the option memory (AR-
MM9) installing section are copied as FAX 
program.
66-24
Purpose
Operation test, check
Function (Content)
Used clear the FAST memory data. 
(Only when FAX is installed.)
Section
FAX
Item
Operation 
Operation/Procedure 1) Select with 10 digit key pad, press START to
execute the following.
  1: Fast memory data clear
  2: Not clear
2) After completion of memory clear, 
reset is made.
SIMULATION 66-23
FAX PROGRAM DOWNLOAD.
EJECT PROTECT PIN, AND PRESS START.
SIMULATION 66-24
FAST MEMORY DATA CLEAR.
ARE YOU SURE ?
1. YES
2. NO
66-25
Purpose
Setup
Function (Content)
Used to register the FAX number for MODEM 
dial-in. (Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure
66-26
Purpose
Setup
Function (Content)
Used to register the external telephone number 
for MODEM dial-in. (Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure
66-27
Purpose
Setup
Function (Content)
Used to register the voice-warp transfer number. 
(Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure
SIMULATION 66-25
M-D-IN FAX NUMBER SETTING. 0-9: [0-9],*: [*],#: [#]
INPUT NUMBER AND PRESS START.
0123456789*#01234567
SIMULATION 66-26
M-D-IN EXTEL NUMBER SETTING. 0-9: [0-9],*: [*],#: [#]
INPUT NUMBER AND PRESS START.
0123456789*#01234567
SIMULATION 66-27
V-WP TRANSMIT NUMBER SETTING. 0-9: [0-9],*: [*],#: [#]
INPUT NUMBER AND PRESS START.
0123456789*#01234567
    !" #$%&'
AR-M350 SIMULATIONS 10-71
<This mode is for development, and inhibited in the market.>
<List of set values>
<This mode is for development, and inhibited in the market.>
<Display message>
66-28
Purpose
Setup
Function (Content)
Used to record a sound message. 
Recording is available in 1 ~ 5, max. 6sec for 
one. (Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure 1) Record a sound message from the handset.
2) Press CUSTOM SETTING to interrupt
recording
66-29
Purpose
Setup
Function (Content)
Used to clear the telephone directory. 
Section
FAX
Item
Operation
Operation/Procedure 1) Select with 10 digit key pad and press START
to execute the following.
  1: Telephone directory clear
  2: Telephone directory not clear
SIMULATION 66-28
VOICE RECORD. SELECT 1-5, AND PRESS START.
1. MESSAGE1
2. MESSAGE2
3. MESSAGE3
4. MESSAGE4
5. MESSAGE5
1
SIMULATION 66-29
ADDRESS DATA CLEAR.
ARE YOU SURE ?
1. YES
2. NO
1
66-30
Purpose
Setup
Function (Content)
Used to check TEL/LIU status change. 
(Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure The TEL/LIU status can be checked.
The display is highlighted when the status is 
changed. 
HS1
Polarity reverse signal
HS2
Polarity reverse signal
RHS
Handset hook SW
EXHS
External telephone hook SW
66-31
Purpose
Setup
Function (Content)
Used to set the TEL/LIU status. 
(Only when FAX is installed.)
Section
Fax
Item
Operation
Operation/Procedure Entry of only 0 or 1 is effective.
Shift the cursor to the bit to enter. 
Cursor shift keys : 
 : * , 
 : #.
The bits are 1, 2, 3, 4, 5, 6, 7, and 8 from the left.
The entered bit is highlighted. 
Press STRT to select the relay.
66-32
Purpose
Setup
Function (Content)
Used to check the received data.
(Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure The fixed data received from the line are 
checked. 
CHECKING
Checking
OK
Checking complete
NG
Checking end
SIMULATION 66-30
TEL/LIU SENSOR CHECK.
HS1
HS2
EXHS
1
RHS
10001100
SIMULATION 66-31
TEL/LIU SETTING.
INPUT O 1, AND PRESS START.
MOVEMENT LEFT: [*] RIGHT: [#]
1. 
2.CION 
3. MR
4. EC
5. 
6. 
7. DP
8.
1 2 3 4 5 6 7 8
MPXA
S.
CML
SIMULATION 66-32
RECEIVED DATA CHECK.
CHECKING...(OK or NG)
    !" #$%&'
AR-M350 SIMULATIONS 10-72
<This mode is for development, and inhibited in the market.>
<Setup for send>
<Result of MODEM writing>
<List of display values>
66-33
Purpose
Setup
Function (Content)
Used to check signal detection. 
Section
FAX
Item
Operation
Operation/Procedure When the signal is detected, the display is 
highlighted.
66-34
Purpose
Setup
Function (Content)
Used to measure and display the communication 
time. 
Section
FAX
Item
Operation
Operation/Procedure The time spent for communication is measured. 
Send/receives performed in the normal mode.
The communication time is displayed with the 
simulation. (unit: ms)
Communication means
memory transmission
Image quality
Normal 
Density
Thin
ECM
ON
Sender record
OFF
66-35
Purpose
Operation test, check 
Function (Content)
Modem program rewriting.
Section
FAX
Item
Operation
Operation/Procedure The modem program in the FAX program is 
rewritten.
1) Select with 10 digit key pad and press START
to execute the following.
  1: MODEM program rewrite
  2:Not clear
2) Check the check sum value (loader). 
If it is OK, the test is normally completed. 
If NG, the check sum value 
(1 byte = hexadecimal) is displayed. 
3) If the check sum value is NG, the MODEM
result is also NG.
4) The Modem rewrite result is displayed.
SIMULATION 66-33
SIGNAL DETECT CHECK.
BUSY TONE
CNG
CED
FNET
DTM
SIMULATION 66-34
COMMUNICATION TIME DISPLAY.
***** ms
COMPLETE
Writing completed
81
Check sum error
82
Write error
83
Delete error
84
Verify error
NG
Due to loader error
66-36
Purpose
Operation test, check
Function (Content)
Used to check interface between MFPC and 
MDMC. Check is made in the data line or the 
command line.
Section
FAX
Item
Operation  
Operation/Procedure 1) Select with 10 digit key pad and press START.
2) When check is "repeat,"  the operation is
executed until the result becomes NG or
CUSTOM SETTING is pressed.
1
MFPC <- MDMC
Data line once only
2
MFPC -> MDMC
Data line once only
3
MFPC <- MDMC
Data line repeat
4
MFPC -> MDMC
Data line repeat
5
MFPC <- MDMC
Command line once only
6
MFPC -> MDMC
Command line once only
7
MFPC <- MDMC
Command line repeat
8
MFPC -> MDMC
Command line repeat
SIMULATION 66-35
MODEM PROGRAM RELOAD.
ARE YOU SURE ?
1. YES
2. NO
1
SIMULATION 66-35
MODEM PROGRAM RELOAD. EXECUTING...
LOADER...(OK or Check Sum value 1 byte (hexadecimal))
MODEM...(COMPLETE or NG code 1 byte (Hexadecimal))
SIMULATION 66-35
MODEM PROGRAM RELOAD.
LOADER...OK
MODEM...COMPLETE
Press [START] key.
After completion of writing
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
1. MFPC<-MDMC(DATA once)
2. MFPC->MDMC(DATA once)
3. MFPC<-MDMC(DATA repeat)
4. MFPC->MDMC(DATA repeat)
5. MFPC<-MDMC(CMD once)
6. MFPC->MDMC(CMD once)
7. MFPC<-MDMC(CMD repeat)
8. MFPC->MDMC(CMD repeat)
1
1
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
EXECUTING...
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
EXECUTING...(OK or NG)
Press [START] key.
When check is "once" or "repeat"
and the result is NG
When check is "repeat" and
[CUSTOM SETTING] key is pressed.
 +   !" #$%&'
AR-M350 SIMULATIONS 10-73
<This simulation is used only for production, and inhibited in the market.>
<Display message>
<Set values>
<Display message>
Main code 67
67-2
Purpose
Operation test, check
Function (Content)
Used to check the parallel I/F operation of the 
printer. 
(This simulation is made only in the production 
site and not in the market. 
It requires a special tool.)
Section
Printer
Item
Operation  
Operation/Procedure The Centro port is checked.
1) Insert the adjustment jig into the Centro port
under the ready state, and press STRT.
2) The Centro port check is started.
3) If normal, OK is displayed. If abnormal, 
the stage number where an error occurred
and NG are displayed. 
WAITING
Waiting
READY
Check start OK
OK
Check complete (normal)
STAGE*NG
Check end (An error occurred in Stage *: 1-11)
67-11
Purpose
Adjustment
Function (Content)
Used to set Enable/Disable of the parallel I/F 
select signal of the printer. 
Section
Printer
Item
Operation
Operation/Procedure The select signal of Centro port is set.
Press START to set.
0
OFF
1
ON (Initial value)
SIMULATION 67-2
CENTRO PORT CHECK.
CENTRO PORT:
READY
SIMULATION 67-2
CENTRO PORT CHECK.
CENTRO PORT:
OK
STAGE7 NG
(or
)
Press [CUSTOM SETTING] key.
Press [START] key
under the ready state.
SIMULATION 67-11
CENTRO SELECT IN SIGNAL SETTING. SELECT 0-1, AND PRESS START.
0. OFF
1. ON
0
67-16
Purpose
Operation test, check
Function (Content)
Used to check the operation of the network card. 
Section
Printer
Item
Operation  
Operation/Procedure The network card is checked.
CHECKING
Checking
OK
Check complete (Normal)
NG
Check end (Abnormal)
SIMULATION 67-16
NETWORK INTERFACE CARD CHECK.
NIC: CHECKING
SIMULATION 67-16
NETWORK INTERFACE CARD CHECK.
NIC: OK (or NG)
Press [CUSTOM SETTING] key.
Check complete
    !" #$%&'