Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ▷ View online
AR-M350 SIMULATIONS 10-54
<List of set values 1>
<List of display values 1>
<List of set values 2>
*
The selected tray is registered as an initial set value in the initial
screen.
Main code 51
51-2
Purpose
Adjustment
Function (Content)
Used to adjust the contact pressure of paper on
the resist roller in each section (machine paper
feed, duplex paper feed, SPF paper feed).
(This adjustment is required when the print
image position varies or when paper jam occurs
frequently.)
the resist roller in each section (machine paper
feed, duplex paper feed, SPF paper feed).
(This adjustment is required when the print
image position varies or when paper jam occurs
frequently.)
Section
Paper transport
(paper exit, switchback, transport)
(paper exit, switchback, transport)
Item
Operation
Operation/Procedure Perform the resist quantity adjustment.
1) The current set value is highlighted on the
right of each item. In this screen, be sure to
select "1: COPY START." (Set value: 1)
select "1: COPY START." (Set value: 1)
2) Enter the correction value with 10 digit key
pad.
Press P to store the set value.
Press P to store the set value.
3) When the value is increased by 1, the resist
quantity is changed by 1ms.
4) Press START to start copying and store the
set value. (Display value: 1)
5) Select a paper feed tray. (Set value 2)
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-8, AND PRESS START.
0. TRAY SELECT
RESIST TIMING ADJUSTMENT. SELECT 0-8, AND PRESS START.
0. TRAY SELECT
1
1.PRINT START
2. TRAY1
50
3. TRAY2
50
4. DESK
50
5. BPT
50
6. ADU
50
7. SPF(HIGH)
50
8. SPF(LOW)
50
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
1. TRAY1
RESIST TIMING ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
1. TRAY1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. NOW PRINTING.
RESIST TIMING ADJUSTMENT. NOW PRINTING.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. BPT
(ABOVE +10: DUPLEX MODE)
RESIST TIMING ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. BPT
(ABOVE +10: DUPLEX MODE)
Press [CUSTOM SETTING] key.
Select 0 or 1,
and press [START] key.
and press [START] key.
Select 1, and
press [START] key.
press [START] key.
Select 0, and
press [START] key.
press [START] key.
Press [START] key or
press [CUSTOME SETTING] key.
press [CUSTOME SETTING] key.
Press [CUSTOM SETTING] key.
Or copying is terminated.
Or copying is terminated.
45PPM 35PPM
0 TRAY
SELECT
Paper feed tray selection (1 - 5)
1 PRINT
START
Copy start (Initial value)
2 TRAY1
Tray 1 resist adjustment value
60
65
3 TRAY2
Tray 2 resist adjustment value
50
55
4 DESK
Desk resist adjustment value
50
55
5 BPT
Manual tray resist adjustment value
55
60
6 ADU
ADU resist adjustment value
50
55
7 SPF(HIGH) SPF resist adjustment value
(High speed)
50
50
8 SPF(LOW) SPF resist adjustment value
(Low speed)
50
50
Normal display
NOW COPYING
ERROR display
Door open
DOOR OPEN.
Jam
JAM
Paper empty
PAPER EMPTY.
1
TRAY1
11
TRAY1 with Duplex
2
TRAY2
12
TRAY2 with Duplex
3
TRAY3
13
TRAY3 with Duplex
4
TRAY4
14
TRAY4 with Duplex
5
Manual feed
15
Manual feed with Duplex
* !" #$%&'
AR-M350 SIMULATIONS 10-55
*
This adjustment is performed only when the width detection volume
is replaced.
Normally use SIM 53-7 for input.
<List of set values>
Main code 53
53-6
Purpose
Adjustment
Function (Content)
Used to adjust the DSPF width detection level.
Section
SPF/DSPF
Item
Operation
Operation/Procedure Adjust the machine SPF document tray size
adjustment.
1) Extend the guide to MAX. position, select 1,
1) Extend the guide to MAX. position, select 1,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
2) Move the guide to A4R position, select 2,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
3) Move the guide to A5R position, select 3,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
4) Move the guide to MIN. position, select 4,
and press START.
When COMPLETE is displayed,
the adjustment is completed.
When COMPLETE is displayed,
the adjustment is completed.
If ERROR is displayed in procedures 1) - 4),
repeat the adjustment again.
repeat the adjustment again.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1. MAX. POSITION
2. POSITION 1
3. POSITION 2
4. MIN. POSITION
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1. MAX. POSITION
2. POSITION 1
3. POSITION 2
4. MIN. POSITION
1
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX. POSITION ... COMPLETE (or "ERROR")
SPF TRAY ADJUSTMENT.
MAX. POSITION ... COMPLETE (or "ERROR")
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or "ERROR")
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or "ERROR")
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or "ERROR")
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or "ERROR")
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN. POSITION ... COMPLETE (or "ERROR")
SPF TRAY ADJUSTMENT.
MIN. POSITION ... COMPLETE (or "ERROR")
Select 1, and
press [START] key.
press [START] key.
Select 2, and
press [START] key.
press [START] key.
Select 3, and
press [START] key.
press [START] key.
Select 4, and
press [START] key.
press [START] key.
Press [CUSTOME SETTING] key.
Press [CUSTOME SETTING] key.
Press [CUSTOME SETTING] key.
Press [CUSTOME SETTING] key.
53-7
Purpose
Adjustment, setup, operation data output, check
(display, print)
(display, print)
Function (Content)
Used to enter the adjustment value of SPF width
detection.
detection.
Section
DSPF
Item
Operation
Operation/Procedure Enter the adjustment value (indicated on the
back of SPF) of SPF document tray size.
Initial value
Range
1
Max. width
66
0 - 1023
2
Adjustment point 1
456
3
Adjustment point 2
713
4
Min. width
791
1
SIMULATION 53-7
SPF TRAY ADJUSTMENT (MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1. MAX. POSITION
SPF TRAY ADJUSTMENT (MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1. MAX. POSITION
66
SIMULATION 53-7
SPF TRAY ADJUSTMENT (MANUAL). SELECT 1-4, AND PRESS START.
1. MAX. POSITION:
SPF TRAY ADJUSTMENT (MANUAL). SELECT 1-4, AND PRESS START.
1. MAX. POSITION:
66
2. POSITION 1:
456
3. POSITION 2:
713
4. MIN. POSITION:
791
Press [CUSTOM SETTING] key.
Press [START] key.
** !" #$%&'
AR-M350 SIMULATIONS 10-56
<List of set values>
<List of set values>
Main code 60
60-1
Purpose
Operation test, check
Function (Content)
Used to check the ICU (DRAM) operation
(read/write).
(SIMM MEMORY/ON BOARD MEMORY)
(read/write).
(SIMM MEMORY/ON BOARD MEMORY)
Section
Image process (ICU)
Item
Operation
Operation/Procedure Perform read/write check of the ICU image
DRUM. After starting, NOW CHECKING is
displayed during checking. When the read/write
check is normally completed, OK is displayed.
If an error occurs, NG is displayed.
displayed during checking. When the read/write
check is normally completed, OK is displayed.
If an error occurs, NG is displayed.
1
ICU DRAM
Image memory for ERDH
2
ASIC DRAM
Image memory for ASIC
SIMULATION 60-1
DRAM TEST. SELECT 1-2, AND PRESS START.
1. ICU DRAM
2. ASIC DRAM
DRAM TEST. SELECT 1-2, AND PRESS START.
1. ICU DRAM
2. ASIC DRAM
1
SIMULATION 60-1
DRAM TEST. ... NOW CHECKING.
1.ICU DRAM
DRAM TEST. ... NOW CHECKING.
1.ICU DRAM
SIMULATION 60-1
DRAM TEST. ... OK (or NG)
1.ICU DRAM
DRAM TEST. ... OK (or NG)
1.ICU DRAM
Press [CUSTOM SETTING] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Check completed
Main code 61
61-1
Purpose
Operation test, check
Function (Content)
Used to check the operations of the laser scan
unit.
unit.
Section
PCU
Item
Operation
Operation/Procedure Check the LSU. Turn on the LSU and check that
the sync signal (HSYNC) is delivered or not.
After starting, NOW CHECKING is displayed
during checking. When the test is normally
completed, OK is displayed. When an error
occurs, NG is displayed.
After starting, NOW CHECKING is displayed
during checking. When the test is normally
completed, OK is displayed. When an error
occurs, NG is displayed.
61-2
Purpose
Adjustment
Function (Content)
Used to adjust the laser power (absolute value)
in the copy mode.
in the copy mode.
Section
PCU
Item
Operation
Operation/Procedure Enter the laser power set value in copying,
and press START to store it.
Initial value
Set range
1
Auto exposure mode
45PPM
104
104 - 150
(45PPM)
80 - 150
(35PPM)
(45PPM)
80 - 150
(35PPM)
35PPM
80
2
Text mode
45PPM
104
35PPM
80
3
Text/Photo mode
45PPM
104
35PPM
80
4
Photo mode
45PPM
104
35PPM
80
SIMULATION 61-1
LSU TEST. PRESS START.
1.LSU
LSU TEST. PRESS START.
1.LSU
1
SIMULATION 61-1
LSU TEST. ... NOW CHECKING.
1. LSU
LSU TEST. ... NOW CHECKING.
1. LSU
SIMULATION 61-1
LSU TEST. ... OK (or NG)
1. LSU
LSU TEST. ... OK (or NG)
1. LSU
Press [CUSTOM SETTING] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Check completed
SIMULATION 61-2
LASER POWER SETTING (COPY). SELECT 1-4, AND PRESS START.
1. AE
LASER POWER SETTING (COPY). SELECT 1-4, AND PRESS START.
1. AE
2. CHARA
3. MIX
4. PHOTO
1
5
SIMULATION 61-2
LASER POWER SETTING(COPY). INPUT VALUE 1-165, AND PRESS START.
1. AE
LASER POWER SETTING(COPY). INPUT VALUE 1-165, AND PRESS START.
1. AE
5
5
5
5
5
Press [START] key.
Press [CUSTOM SETTING] key
or [START] key.
*, !" #$%&'
AR-M350 SIMULATIONS 10-57
<List of set values>
<List of set values>
<List of set values>
<List of set values>
61-3
Purpose
Adjustment
Function (Content)
Used to adjust the scanner (exposure) laser
power (absolute value) in the FAX reception
mode. (Only when FAX is installed.)
power (absolute value) in the FAX reception
mode. (Only when FAX is installed.)
Section
PCU
Item
Operation
Operation/Procedure Set the laser power in FAX reception.
Enter the set value and press Start to store it.
Initial value
Set range
1
FAX reception
45PPM
104
104 - 150
(45PPM)
80 - 150
(35PPM)
(45PPM)
80 - 150
(35PPM)
35PPM
80
61-4
Purpose
Adjustment
Function (Content)
Used to adjust the laser power (absolute value)
in the printer mode.
in the printer mode.
Section
PCU
Item
Operation/Procedure Set the laser power value in the printer mode.
Operation/Procedure Set the laser power value in the printer mode.
Enter the value and press START to store it.
Initial value
Set range
1
PRINTER
45PPM
104 104
-
150
(45PPM)
80 - 150
(35PPM)
80 - 150
(35PPM)
35PPM
80
SIMULATION 61-3
LASER POWER SETTING (FAX). PRESS START.
1. FAX
LASER POWER SETTING (FAX). PRESS START.
1. FAX
1
5
SIMULATION 61-3
LASER POWER SETTING (FAX). INPUT VALUE 1-165, AND PRESS START.
1. FAX
LASER POWER SETTING (FAX). INPUT VALUE 1-165, AND PRESS START.
1. FAX
5
Press [START] key.
Press [CUSTOM SETTING] key
or [START] key.
SIMULATION 61-4
LASER POWER SETTING (PRINTER). PRESS START.
1. PRINTER
LASER POWER SETTING (PRINTER). PRESS START.
1. PRINTER
1
5
SIMULATION 61-4
LASER POWER SETTING (PRINTER). INPUT VALUE 1-165, AND PRESS
LASER POWER SETTING (PRINTER). INPUT VALUE 1-165, AND PRESS
START.
1. PRINTER
5
Press [START] key.
Press [CUSTOM SETTING] key
or [START] key.
Main code 62
62-2
Purpose
Operation test, check
Function (Content)
Used to check the hard disk operation
(read/write).
(Only for the model with the hard disk)
(Partial check)
(read/write).
(Only for the model with the hard disk)
(Partial check)
Section
Memory
Item
Operation
Operation/Procedure Perform the partial check of read/write of the
hard disk. EXECUTING is displayed during
check. When check is normally completed,
OK is displayed.
When an error occurs, NG is displayed.
check. When check is normally completed,
OK is displayed.
When an error occurs, NG is displayed.
1
Execution
2
Cancel
62-3
Purpose
Operation test, check
Function (Content)
Used to check the hard disk operation
(read/write).
(Only for the model with the hard disk)
(All area check)
(read/write).
(Only for the model with the hard disk)
(All area check)
Section
Memory
Item
Operation
Operation/Procedure Perform the all area check of read/write of the
hard disk. EXECUTING is displayed during
check. When check is normally completed,
OK is displayed. When an error occurs,
NG is displayed.
check. When check is normally completed,
OK is displayed. When an error occurs,
NG is displayed.
1
Execution
2
Cancel
SIMULATION 62-2
HDD R/W TEST.
ARE YOU SURE?
1. YES
2. NO
HDD R/W TEST.
ARE YOU SURE?
1. YES
2. NO
1
SIMULATION 62-2
HDD R/W TEST. EXECUTING...
HDD R/W TEST. EXECUTING...
SIMULATION 62-2
HDD R/W TEST.OK. (or NG)
HDD R/W TEST.OK. (or NG)
Press [START] key.
After completion
Press [CUSTOM SETTING] key to stop.
SIMULATION 62-3
HDD R/W TEST ALL.
ARE YOU SURE?
1. YES
2. NO
HDD R/W TEST ALL.
ARE YOU SURE?
1. YES
2. NO
1
SIMULATION 62-3
HDD R/W TEST. EXECUTING...
HDD R/W TEST. EXECUTING...
SIMULATION 62-3
HDD R/W TEST.OK. (or NG)
HDD R/W TEST.OK. (or NG)
Press [START] key.
After completion
Press [CUSTOM SETTING] key to stop.
* !" #$%&'
Click on the first or last page to see other AR-M35 / AR-M450 (serv.man12) service manuals if exist.