Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ▷ View online
AR-M350 SIMULATIONS 10-34
<List of display values>
<List of display values>
41-3
Purpose
Operation test, check
Function (Content)
Used to check the operation of the document
size sensor and the related circuit.
(The output level of the document size sensor
can be monitored on the LCD display.)
size sensor and the related circuit.
(The output level of the document size sensor
can be monitored on the LCD display.)
Section
Other
Item
Operation
Operation/Procedure The OC document sensor detection level is
displayed. (Real time display)
OCSW
Original cover state
Open : Normal display
Close : Highlighted
Open : Normal display
Close : Highlighted
PD1 ~ 7
PD sensor detection level
Figures in [ ] indicate the adjustment threshold values
(41-2 adjustment value).
Figures in [ ] indicate the adjustment threshold values
(41-2 adjustment value).
SIMULATION 41-3
PD SENSOR DATA DISPLAY.
PD SENSOR DATA DISPLAY.
OCSW
PD1[128]: 200
PD2[128]: 200
PD3[128]: 50
PD4[128]: 52
PD5[128]: 51
PD6[128]: 50
PD7[128]: 52
Main code 43
43-1
Purpose
Setup
Function (Content)
Used to set the fusing temperature in each
operation mode.
operation mode.
Section
Fusing, paper exit
Item
Operation
Operation/Procedure The fusing control temperature is set.
The current set value is highlighted on the right
of each item. Select an item (1 - 6), and enter a
set value with 10 digit key pad. Press START key
to store the value.
of each item. Select an item (1 - 6), and enter a
set value with 10 digit key pad. Press START key
to store the value.
Default
Set range
1
Heater inside/Normal
190
165~210
2
Heater outside/Normal
190
165~210
3
Heater inside/Pre-heat
150
100~160
4
Heater outside/Pre-heat
150
100~160
5
Heater inside/Manual paper feed
used
used
190
165~210
6
Heater outside/Manual paper feed
used
used
190
165~210
1
SIMULATION 43-1
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
190
SIMULATION 43-1
FUSER TEMPERATURE SET. SELECT 1 - 6, AND PRESS START.
1. INSIDE NORMAL
FUSER TEMPERATURE SET. SELECT 1 - 6, AND PRESS START.
1. INSIDE NORMAL
190
5. INSIDE MPT
180
2. OUTSIDE NORMAL
190
6. OUTSIDE MPT
180
3. INSIDE PREHEAT
130
4. OUTSIDE PREHEAT
130
Press [CUSTOM SETTING] key.
Press [START] key.
(Enter the value with 10-key)
!" #$%&
AR-M350 SIMULATIONS 10-35
<List of display values>
*1: Only when this value is 0, control is performed with the actual
measurement value of process Thermistor.
If it is not 0, control is forcibly performed.
*2: When the drum motor standby time is greater than this value, the
correction of SIM 44-1 Vb1 is performed.
*3: This value is SIM 44-9 Vb1-1 correction value. The value
corresponding to the drum rotating time is used.
*4: This value is SIM 44-9 Vb1-2 correction value. The value
corresponding to the drum rotating time is used.
<List of display values>
*1: Vb1-1 and Vb1-2 are enabled or disabled by SIM 44-1 Vb1 setup.
*2: When PTH is set to 0 with SIM 44-4, the detected value in this
*2: When PTH is set to 0 with SIM 44-4, the detected value in this
adjustment is displayed. If PTH is set to other than 0, the value set
with SIM 44-4 is displayed.
Main code 44
44-1
Purpose
Setup
Function (Content)
Used to set Enable/Disable of each correction
operation in the image forming (process)
section.
operation in the image forming (process)
section.
Section
Process
(OPC drum, developing, transfer, cleaning)
(OPC drum, developing, transfer, cleaning)
Item
Operation
Operation/Procedure
44-4
Purpose
Setup
Function (Content)
Used to set the target image (reference) density
level in the developing bias voltage correction.
level in the developing bias voltage correction.
Section
Process
(OPC drum, developing, transfer, cleaning)
(OPC drum, developing, transfer, cleaning)
Item
Data
Operation/Procedure The process correction value is set.
Select an item (1 - 9), and enter a value with
10 digit key pad. Press SYTART to store the
value.
10 digit key pad. Press SYTART to store the
value.
1 PTH *1
Process Thermistor temperature forcible set value
(0-99°C : Normal 0)
(0-99°C : Normal 0)
2 S_WT *2 Vb (Devepoping bias correction value) rising correction
wait time (0-180sec : Default 90)
3 Vb1-1 *3 Vb (Devepoping bias correction value) correction quantity
(First rotation) 1 (0 - 150V : Default 50)
4 Vb1-2 *3 Vb (Devepoping bias correction value) correction quantity
(First rotation) 2 (0 - 150V : Default 50)
5 Vb1-3 *3 Vb (Devepoping bias correction value) correction quantity
(First rotation) 3 (0 - 150V : Default 50)
6 Vb2-1 *4 Vb (Devepoping bias correction value) correction quantity
(Second rotation) 1 (0 - 50V : Default 15)
7 Vb2-2 *4 Vb (Devepoping bias correction value) correction quantity
(Second rotation) 2 (0 - 50V : Default 15)
8 Vb2-3 *4 Vb (Devepoping bias correction value) correction quantity
(Second rotation) 3 (0 - 50V : Default 15)
SIMULATION 44-1
PROCESS CORRECTION VALUE SETTING. INPUT VALUE 0-127
AND PRESS START.
BIT0:Vg1, BIT1:Vg2, BIT2:Vb1, BIT3:Vb2
BIT4:Vb3, BIT5:LD1, BIT6:LD2
PROCESS CORRECTION VALUE SETTING. INPUT VALUE 0-127
AND PRESS START.
BIT0:Vg1, BIT1:Vg2, BIT2:Vb1, BIT3:Vb2
BIT4:Vb3, BIT5:LD1, BIT6:LD2
127
0
15
0
14
0
13
0
12
0
11
0
10
0
0
0
9
8
7
LD2
6
LD1
5
Vb3
4
Vb2
3
Vb1
2
Vg2
1
Vg1
0
Bit
bit = 1 : Correction enabled
1
SIMULATION 44-4
PROCESS CONTROL VALUE SETTING. INPUT VALUE, AND PRESS
START.
1.PTH
PROCESS CONTROL VALUE SETTING. INPUT VALUE, AND PRESS
START.
1.PTH
45
SIMULATION 44-4
PROCESS CONTROL VALUE SETTING. SELECT 1-8 AND PRESS
START.
1.PTH
PROCESS CONTROL VALUE SETTING. SELECT 1-8 AND PRESS
START.
1.PTH
00
2.S-WT
100
3.Vb1-1
50
4.Vb1-2
50
5.Vb1-3
50
6.Vb2-1
50
7.Vb2-2
50
8.Vb2-3
50
Press [CUSTOM SETTING] key.
Press [START] key.
DRUM ROTATION TOME
Vb1 correction value
(X’ th rotation)
45PPM
35PPM
0 ~ 40K (sec)
0 ~ 50K (sec)
(X’ th rotation) -1
40 ~ 80K (sec)
50 ~ 95K (sec)
(X’ th rotation) -2
80K ~ (sec)
95K ~ (sec)
(X’ th rotation) -3
44-9
Purpose
Adjustment, setup, operation data output, check
(display)
(display)
Function (Content)
Used to check the result (main charger grid
voltage developing bias voltage, laser power,
etc.) of correction (process correction) in the
image forming section.
(By this simulation, the correction operation can
be checked.)
voltage developing bias voltage, laser power,
etc.) of correction (process correction) in the
image forming section.
(By this simulation, the correction operation can
be checked.)
Section
Process
(OPC drum, developing, transfer, cleaning)
(OPC drum, developing, transfer, cleaning)
Item
Data
Operation/Procedure The process correction value is checked.
DRUM ROTATION TIME Drum rotation time
Vg1~Vg2
Vg1~Vg2
Grid voltage correction value
Vb1-1 *1
Vb (Developing bias correction value)
correction value (first rotation)
correction value (first rotation)
Vb1-2 *1
Vb (Developing bias correction value)
correction value (second rotation)
correction value (second rotation)
Vb2
Developing bias correction value
Vb3
Developing bias correction value
LD1
Laser power correction value
LD2
Laser power correction value
CONTROL
CRUM control spec (1 - 3)
DESTINATION
CRUM destination (A - J)
PTH *2
Process Thermistor temperature value
T0
Toner control correction value
(Rotation time correction) (±100)
(Rotation time correction) (±100)
T1
Toner control correction value T1
(Temperature correction) (±100)
(Temperature correction) (±100)
T2
Toner control correction value T2
(Temperature correction) (±100)
(Temperature correction) (±100)
SIMULATION 44-9
PROCESS CONTROL DATA DISPLAY.
DRUM ROTATION TIME:
PROCESS CONTROL DATA DISPLAY.
DRUM ROTATION TIME:
01234567
(sec)
Vg1:
30
(V) Vg2:
30
(V)
Vb1-1:
30
(V)
Vb1-2:
30
(V)
Vb2:
10
(V)
LD1:
0.05
(mW)
LD2:
0.05
(mW)
CONTROL:
1
DESTINATION:
A
PTH:
30
(deg)
TO:
-5
T1:
-5
T2:
-3
( !" #$%&
AR-M350 SIMULATIONS 10-36
<List of set values 1>
<List of display values 1>
<List of set values 2>
<List of set values 3>
Main code 46
46-2
Purpose
Adjustment
Function (Content)
Used to adjust the copy density in the copy mode
(binary, auto, text, text/photo, photo mode).
An adjustment with this simulation affects all the
reading density adjustment values.
(binary, auto, text, text/photo, photo mode).
An adjustment with this simulation affects all the
reading density adjustment values.
Section
Item
Item
Picture quality
Operation/Procedure The exposure mode to be set is selected.
(Auto adjustment)
1) The current set value is highlighted on the
1) The current set value is highlighted on the
right side of each item. In this screen, be sure
to select "1: COPY START." (Set value: 1)
to select "1: COPY START." (Set value: 1)
2) Set the exposure level with 10 digit key pad.
Press P to store the set value.
(Default: 50, set range: 0 - 99)
(Default: 50, set range: 0 - 99)
3) Press START, and copying is started and the
set value is stored. (Display value 1)
4) Select a paper feed tray. (Set value 2)
5) Select an exposure level. (Set value 3)
5) Select an exposure level. (Set value 3)
SIMULATION 46-2
EXP. LEVEL SETUP (2). SELECT 0-6, AND PRESS START.
0. TRAY SELECT
EXP. LEVEL SETUP (2). SELECT 0-6, AND PRESS START.
0. TRAY SELECT
1. COPY START
2. EXP LEVEL
3. AE 3.0
3. AE 3.0
4. CH 3.0
5. MIX 3.0
6. PHOTO 3.0
1
50
SIMULATION 46-2
EXP. LEVEL SETUP (2). SELECT 1-5, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. BPT
EXP. LEVEL SETUP (2). SELECT 1-5, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. BPT
1
SIMULATION 46-2
EXP. LEVEL SETUP (2). NOW COPYING.
EXP. LEVEL SETUP (2). NOW COPYING.
SIMULATION 46-2
EXP. LEVEL SETUP (2). SELECT 3-6, AND PRESS START.
(EXP. LEVEL SELECT)
3. AE 3.0 4. CH 3.0
5. MIX 3.0 6. PHOTO 3.0
EXP. LEVEL SETUP (2). SELECT 3-6, AND PRESS START.
(EXP. LEVEL SELECT)
3. AE 3.0 4. CH 3.0
5. MIX 3.0 6. PHOTO 3.0
1
50
50
1
1
50
50
SIMULATION 46-2
EXP. LEVEL SETUP (2),INPUT VALUE 0-99, AND PRESS START.
3. AE 3.0
EXP. LEVEL SETUP (2),INPUT VALUE 0-99, AND PRESS START.
3. AE 3.0
Press [CUSTOM SETTING] key.
Select other than 0 - 2,
and press [START] key.
and press [START] key.
Select 1, and
press [START] key.
press [START] key.
Select 2, and
press [START] key.
press [START] key.
Select 0, and
press [START] key.
press [START] key.
Press [START] key.
Press [START] key or
press [CUSTOME SETTING] key.
press [CUSTOME SETTING] key.
Press [START] key or
press [CUSTOME SETTING] key.
press [CUSTOME SETTING] key.
Press [CUSTOM SETTING] key.
Or copying is terminated.
Or copying is terminated.
0
Paper feed tray selection
1
Copy start (Default)
2
Exposure level selection
3
AE mode
4
Text mode 30
5
Text/Photo mode 30
6
Photo mode 30
Normal display
NOW COPYING
ERROR display
Door open
DOOR OPEN.
Jam
JAM
paper empty
PAPER EMPTY.
1
TRAY1
2
TRAY2
3
TRAY3
4
TRAY4
5
Manual feed
3
AE mode
4
Text mode 30
5
Text/Photo mode 30
6
Photo mode 30
!" #$%&
AR-M350 SIMULATIONS 10-37
<List of set values 1>
<List of display values 1>
<List of set values 2>
<List of set values 3>
46-9
Purpose
Adjustment
Function (Content)
Used to adjust the print density for each density
level (display value) in the copy mode
(binary-Text mode).
A desired reading density can be set for each
density level (display value).
level (display value) in the copy mode
(binary-Text mode).
A desired reading density can be set for each
density level (display value).
Section
Item
Item
Picture quality
Operation/Procedure The exposure mode to be set is selected.
(Text mode)
1) The current set value is highlighted on the
1) The current set value is highlighted on the
right side of each item. In this screen, be sure
to select "1: COPY START." (Set value: 1)
to select "1: COPY START." (Set value: 1)
2) Set the exposure level with 10 digit key pad.
Press P to store the set value.
(Default: 50, set range: 0 - 99)
(Default: 50, set range: 0 - 99)
3) Press START, and copying is started and the
set value is stored. (Display value 1)
4) Select a paper feed tray. (Set value 2)
5) Select an exposure level. (Set value 3)
5) Select an exposure level. (Set value 3)
SIMULATION 46-9
EXP. LEVEL SETUP (CHAR.2). SELECT 0-11, AND PRESS START.
0. TRAY SELECT
EXP. LEVEL SETUP (CHAR.2). SELECT 0-11, AND PRESS START.
0. TRAY SELECT
1. COPY START
2. EXP LEVEL
3. 1.0
3. 1.0
4. 1.5
5. 2.0
6. 2.5.
7. 3.0
8. 3.5
9. 4.0
10. 4.5
11. 5.0
1
SIMULATION 46-9
EXP. LEVEL SETUP (CHAR.2),INPUT VALUE 0-99, AND PRESS START.
3. 1. 0
EXP. LEVEL SETUP (CHAR.2),INPUT VALUE 0-99, AND PRESS START.
3. 1. 0
50
SIMULATION 46-9
EXP. LEVEL SETUP (CHAR.2). SELECT 1-5, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. BPT
EXP. LEVEL SETUP (CHAR.2). SELECT 1-5, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. BPT
1
SIMULATION 46-9
EXP. LEVEL SETUP (CHAR.2). NOW COPYING.
EXP. LEVEL SETUP (CHAR.2). NOW COPYING.
SIMULATION 46-9
EXP. LEVEL SETUP (CHAR.2). SELECT 3-11, AND PRESS START.
(EXP. LEVEL SELECT)
3. 1.0
EXP. LEVEL SETUP (CHAR.2). SELECT 3-11, AND PRESS START.
(EXP. LEVEL SELECT)
3. 1.0
4. 1.5
5. 2.0
6. 2.5.
7. 3.0
8. 3.5
9. 4.0
10. 4.5
11. 5.0
1
50
50
50
50
50
50
50
1
1
50
50
Press [CUSTOM SETTING] key.
Select other than 0 - 2,
and press [START] key.
and press [START] key.
Select 1, and
press [START] key.
press [START] key.
Select 2, and
press [START] key.
press [START] key.
Select 0, and
press [START] key.
press [START] key.
Press [START] key.
Press [START] key or
press [CUSTOME SETTING] key.
press [CUSTOME SETTING] key.
Press [START] key or
press [CUSTOME SETTING] key.
press [CUSTOME SETTING] key.
Press [CUSTOM SETTING] key.
Or copying is terminated.
Or copying is terminated.
0
Paper feed tray selection
1
Copy start (Default)
2
Exposure level selection
3
Exposure level 1.0
4
Exposure level 1.5
5
Exposure level 2.0
6
Exposure level 2.5
7
Exposure level 3.0
8
Exposure level 3.5
9
Exposure level 4.0
10
Exposure level 4.5
11
Exposure level 5.0
Normal display
NOW COPYING
ERROR display
Door open
DOOR OPEN.
Jam
JAM
paper empty
PAPER EMPTY.
1
TRAY1
2
TRAY2
3
TRAY3
4
TRAY4
5
Manual feed
3
Exposure level 1.0
4
Exposure level 1.5
5
Exposure level 2.0
6
Exposure level 2.5
7
Exposure level 3.0
8
Exposure level 3.5
9
Exposure level 4.0
10
Exposure level 4.5
11
Exposure level 5.0
) !" #$%&
Click on the first or last page to see other AR-M35 / AR-M450 (serv.man12) service manuals if exist.