DOWNLOAD Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ↓ Size: 7.51 MB | Pages: 112 in PDF or view online for FREE

Model
AR-M35 AR-M450 (serv.man12)
Pages
112
Size
7.51 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual Section 2 - Disassembly, Machine Operation, Adjustments, Simulations, Trouble Codes
File
ar-m35-ar-m450-sm12.pdf
Date

Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ▷ View online

AR-M350 SIMULATIONS 10-14
*
CIS is displayed only when DSPF is installed.
<List of set values>
*1 Displayed when OPTION of multi-purpose only.
*2 Displayed when manual feed OPTION is added.
5-3
Purpose
Operation test, check
Function (Content)
Used to check the operations of the copy lamp 
and its control circuit.  
Section
Scanner (reading), DSPF (reading)
Item
Operation
Operation/Procedure The copy lamp or CIS is lighted for 10sec and 
turned off. 
SIMULATION 5-3
COPY LAMP TEST. SELECT 1-2, AND PRESS START.
1.COPY LAMP
2.CIS
1
SIMULATION 5-3
COPY LAMP TEST. EXECUTING...
1.COPY LAMP
2.CIS
1
Press [START] key to get started.
Press [CUSTOM SETTING] key to stop.
Stops after 10sec.
Main code 6
6-1
Purpose
Operation test, check
Function (Content)
Used to check the operation under load 
(clutches and solenoids) in the paper transport 
system and their control circuits. 
Section
Paper transport (paper exit, switchback, 
transport)
Item
Operation
Operation/Procedure Select with 10 digit key pad.
2
HLPR (Heater power relay)
3
DCPR (DC power relay)
4
MM  (Main motor)
5
DM (Drum motor)
6
DSB_FW (Stepping motor forward rotation)
7
DSB_RV (Stepping motor reverse rotation)
8
CPFC (Paper feed clutch)
9
RRC (Resist roller clutch)
10
TRC (Transport roller clutch)
11
FGS_FIN (Finisher gate solenoid)
12
LUM (Tray 1 lift-up motor)
13
TRC_DSK (Desk clutch sync signal)
14
PSPS (Separation pawl solenoid)
15*1
MCM(MP drive motor control signal)
16*1
MCPCL(MP tray paper feed clutch signal)
17*1
MCFCL(MP tray transport clutch signal)
18*1
MCLUM(MP tray lift-up motor signal)
19*2
MPFS (Manual paper feed solenoid signal)
20*2
MPFC (Manual paper feed clutch signal)
21*2
MSS (Manual paper feed gate solenoid)
SIMULATION 6-1
FEED OUTPUT CHECK. SELECT 1-17, AND PRESS START.
2.HLPR
3.DCPR
4.MM
5.DM
6.DSB_FW
7.DSB_RV  8.CPFC
9.RRC
10.TRC
11.FGS_FIN
12.LUM
13.TRC_DSK
14.PSPS
15.MCM
16.MCPCL  17.MCFCL  18.MCLUM
19.MPFS  20.MPFC  21.MSS
2
SIMULATION 6-1
FEED OUTPUT CHECK. EXECUTING...
2.HLPR 3.DCPR 4.MM 5. DM 6.DSB_FW
7.DSB_RV  8.CPFC 9.RRC 10.TRC 11. FGS_FIN
12.LUM
13.TRC_DSK
14.PSPS
15.MCM
16.MCPCL  17.MCFCL  18.MCLUM
19.MPFS  20.MPFC  21.MSS
2
Press [START] key to get started.
Press [CUSTOM SETTING] key to stop.
Or stops after repeating
the specified number of times.
 (     !"#$%&
AR-M350 SIMULATIONS 10-15
<List of set values>
<List of set values>
6-2
Purpose
Operation test, check
Function (Content)
Used to check the operations of each fan motor 
and its control circuit. 
Section
Others
Item
Operation
Operation/Procedure Select with 10 digit key pad.
1
Fan motor high speed
2
Fan motor low speed
SIMULATION 6-2
FAN MOTOR CHECK. SELECT 1-2, AND PRESS START.
1. FMHi
2. FMLo
2
SIMULATION 6-2
FAN MOTOR CHECK. SELECT 1-2, AND PRESS START.
1. FMHi
2. FMLo
2
Press [START] key to get started.
Press [CUSTOM SETTING] key to stop.
Main code 7
7-1
Purpose
Setup
Function (Content)
Used to set the aging conditions. 
Section
Item
Operation
Operation/Procedure Select with 10 digit key pad.
0
No jam detection
1
Aging mode
2
Aging mode without jam detection
3
Aging mode without jam/without warm-up/without fusing 
temperature control
4
Without warm-up
5
Intermittent aging mode
6
Intermittent aging mode without jam detection
Above +10 No process unit (including developing unit) detection
Above +20 No shading
Above +30 No process unit detection/No shading
7-6
Purpose
Setup
Function (Content)
Used to set the intermittent aging cycle. 
Section
Item
Operation
Operation/Procedure Select with 10 digit key pad. Used to set the 
intermittent aging cycle of Sim 7-1.
SIMULATION 7-1
AGING TEST SETTING. SELECT 0-36, AND PRESS START.
0. NO MISS FEED DETECTION
1. AGING
2. AGING/NO MISS FEED DETECTION.
3. AGING/NO MISS FEED DETECTION/
NO WARM UP/NO TEMPERATURE CONTROL.
4. NO WARM UP.
5. AGING/INTERVAL.
6. AGING/INTERVAL/NO MISS FEED DETECTION.
+10 : NO PROCESS UNIT CHECK.
+20 : NO SHADING.
+30 : NO PROCESS UNIT CHECK/NO SHADING.
2
Press [START] key to register.
The operation mode is kept until the power is turned off or setting is made again.
SIMULATION 7-6
INTERVAL AGING CYCLE SETUP. INPUT TIME AND PRESS START.
(1-999, UNIT: sec)
10
 )     !"#$%&
AR-M350 SIMULATIONS 10-16
<List of set values>
7-8
Purpose
Setup
Function (Content)
Used to set Enable/Disable of warm-up time 
display. 
Section
Item
Operation
Operation/Procedure The warm-up time is displayed in the unit of 
second. 
SIMULATION 7-8
WARM UP TIME DISPLAY.
ARE YOU SURE?
1. YES
2. NO
1
SIMULATION 7-8
WARM UP TIME DISPLAY. WARMING UP,PLEASE WAIT.
(UNIT:sec)
30
SIMULATION 7-8
WARM UP TIME DISPLAY. WARM UP COMPLETED.
(UNIT:sec)
60
Press [START] key to start measuring. Press [CUSTOM SETTING] key to stop.
Warm-up ends.
Press [CUSTOM SETTING] key.
Main code 8
8-1
Purpose
Adjustment
Function (Content)
Used to check and adjust the developing bias 
voltage in each print mode and its control circuit. 
Section
Process 
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure Enter the output value to be adjusted with 
10 digit key pad. The current set value is 
highlighted at the right of each item. 
After entering the value press START key. 
10 digit key padThe output is made for 30sec at 
the set value. 
Then the output is stopped.
Default
Set range
1
Auto mode
485
0 ~745
2
Text mode
3
Text/Photo mode
4
Photo mode
5
Printer mode
6
Fax mode
7
Reverse developing bias voltage
150
0 ~255
1
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1 : AUTO (0-745)
500
SIMULATION 8-1
DV BIAS SETTING. EXECUTING...
1 : AUTO
500
SIMULATION 8-1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO
500
2.CHARACTER
500
3.MIX
500
34.PHOTO
500
5.PRINTER
500
6.FAX
500
7.PLUS
500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
 *     !"#$%&
AR-M350 SIMULATIONS 10-17
<List of set values>
<List of set values>
<List of set values>
8-2
Purpose
Adjustment
Function (Content)
Used to check and adjust the main charger grid 
voltage in each print mode and its control circuit. 
Section
Process 
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure Enter the output value to be adjusted with 
10 digit key pad. The current set value is 
highlighted at the right of each item. 
After entering the value with 10 digit key pad, 
press START key. 
The output is made for 30sec at the set value. 
Then the output is stopped.
Default
Set range
1
Auto mode
645
200 ~ 900
2
Text mode
3
Text/Photo mode
4
Photo mode
5
Printer mode
6
Fax mode
8-6
Purpose
Adjustment
Function (Content)
Used to check and adjust the transfer charger 
current and its control circuit. 
Section
Process 
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure Enter the output value to be adjusted with 
10 digit key pad. The current set value is 
highlighted at the right of each item. 
After entering the value with 10 digit key pad, 
press START key. 
The output is made for 30sec at the set value. 
Then the output is stopped.
1
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1. AUTO (200-900)
500
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING...
1 : AUTO
500
SIMULATION 8-2
MAIN GRID SETTING. SELECT 1- 6, AND PRESS START.
1. AUTO
500
2. CHARACTER
500
3. MIX
500
4. PHOTO
500
5. PRINTER
500
6. FAX
500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
Default
Set range
1 Cassette/manual paper feed
45PPM
267
0 ~ 620
35PPM
220
2 Paper feed from ADU
45PPM
310
35PPM
267
8-17
Purpose
Operation test, check
Function (Content)
Used to set and check the transfer roller output. 
Section
Process 
(OPC drum, developing, transfer, cleaning)
Item
Operation
Operation/Procedure Enter the output value to be adjusted with 
10 digit key pad. The current set value is 
highlighted at the right of each item. 
After entering the value with 10 digit key pad, 
press START key. 
The output is made for 30sec at the set value. 
Then the output is stopped.
Default
Set range
1
SHV front surface
160(45PPM)
120(35PPM)
0 ~ 375
2
SHV back surface
3
THV-output
780
0 ~1250
1
SIMULATION 8-6
THV+SETTING. INPUT VALUE, AND PRESS START.
1. FRONT(0-620)
140
SIMULATION 8-6
THV+SETTING. EXECUTING...
1. FRONT
140
SIMULATION 8-6
THV+SETTING. SELECT 1-2, AND PRESS START.
1. FRONT
140
2. BACK
140
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
1
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1. FRONT (0-375)
500
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING...
1. FRONT (0-375)
500
SIMULATION 8-17
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1. SHV FRONT
500
2. SHV BACK
500
3. THV-
500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
 +     !"#$%&
Page of 112
Display

Click on the first or last page to see other AR-M35 / AR-M450 (serv.man12) service manuals if exist.