Sharp AR-M165-207 (serv.man25) User Manual / Operation Manual ▷ View online
35
ADVANCED TRANSMISSION METHODS
3
8
Press the [OK] key.
The selected day is set.
9
Perform the desired fax operation.
The steps that follow will depend on the type of
operation.
The following operations can be performed as a
timer operation:
operation.
The following operations can be performed as a
timer operation:
• Normal transmission (page 18)
• Broadcast transmission (page 32)
• Polling (page 36)
• Serial polling (page 38)
• F-code polling (page 53)
• F-code confidential transmission (page 55)
• F-code relay request transmission (page 59)
• Broadcast transmission (page 32)
• Polling (page 36)
• Serial polling (page 38)
• F-code polling (page 53)
• F-code confidential transmission (page 55)
• F-code relay request transmission (page 59)
OK
• To cancel a timer operation after the above procedure has been completed, follow the procedure in
"CANCELLING A FAX TRANSMISSION" (page 26).
• A timer job number is automatically assigned to the operation. This number can be used to cancel a stored job.
(See the note "Contents of the stored job screen (screen of step 3)" on page 27.)
• Other operations can be performed after a timer operation is set up. If another operation is in progress when
the specified time arrives, the timer transmission will begin when the job in progress is completed.
Note
Pegasus-E_Fax_Ex.book 35 ページ 2004年10月18日 月曜日 午後8時41分
36
TRANSMISSION AND RECEPTION USING THE POLLING FUNCTION
The polling function allows your machine to call a fax machine that has a document ready for transmission and
initiate reception of the document. You can also perform the reverse operation: scan a document into the memory of
your machine so that another machine can call your machine and initiate reception of the document.
Calling the sending machine and asking the sending machine to fax a document is called "polling". Scanning a document into
memory and automatically sending it when the receiving machine calls and "polls" your machine is called "polling memory".
This function can only be used if the other machine is a Super G3 or G3 machine and supports the polling function.
initiate reception of the document. You can also perform the reverse operation: scan a document into the memory of
your machine so that another machine can call your machine and initiate reception of the document.
Calling the sending machine and asking the sending machine to fax a document is called "polling". Scanning a document into
memory and automatically sending it when the receiving machine calls and "polls" your machine is called "polling memory".
This function can only be used if the other machine is a Super G3 or G3 machine and supports the polling function.
Polling
This function allows your machine to call another fax machine and initiate reception of a document in that machine. A timer setting can
also be specified to have the operation take place at night or at another specified time. (See "TIMER TRANSMISSION" on page 34.)
also be specified to have the operation take place at night or at another specified time. (See "TIMER TRANSMISSION" on page 34.)
Group keys and the broadcast transmission function (page 32) can be used to successively poll multiple fax
machines in a single operation (this is called "serial polling"). Up to 200 machines can be polled.
In this case, the sequence of operations in the above diagram is successively repeated for each sending machine selected.
machines in a single operation (this is called "serial polling"). Up to 200 machines can be polled.
In this case, the sequence of operations in the above diagram is successively repeated for each sending machine selected.
Polling memory
This feature allows your machine to automatically send a document previously scanned into memory when another
machine calls and polls your machine.
machine calls and polls your machine.
For information on polling and polling memory using F-codes, see "HOW F-CODE POLLING MEMORY
WORKS" (page 50). Normal polling and memory polling are explained in this chapter.
WORKS" (page 50). Normal polling and memory polling are explained in this chapter.
The receiving machine bears the expense (phone charges) of polling transmission.
The machine that requests transmission bears the expense (phone charges) of the call.
Note
The other machine
Your machine
2) Permits polling of.
1) Polling (ask other machine
to send document)
4) Document data is automatically
sent to your machine
3) Document data previously
scanned into memory
Note
2) Permits polling of.
Your machine
The other machine
3) Document data previously
scanned into memory
1) Polling
(request transmission)
4) Document data is
automatically sent to
other machine
other machine
Note
Pegasus-E_Fax_Ex.book 36 ページ 2004年10月18日 月曜日 午後8時41分
37
ADVANCED TRANSMISSION METHODS
3
USING THE POLLING FUNCTION
When used in conjunction with the timer transmission function (page 34), only one polling job can be stored.
1
In Fax mode, press the [SPECIAL
FUNCTION] key.
FUNCTION] key.
When the [SPECIAL
FUNCTION] key is pressed, the
special function menu appears.
(To select fax mode, see step 1
on page 18.)
FUNCTION] key is pressed, the
special function menu appears.
(To select fax mode, see step 1
on page 18.)
2
Select "SENDING OPTIONS" with the
[
[
] or [
] key.
3
Press the [OK] key.
4
Select "POLLING" with the [
] or [
]
key.
5
Press the [OK] key.
6
Enter the fax number of the other
machine with the numeric keys, press
a Rapid key, or specify a Speed Dial
number (a group key cannot be used).
machine with the numeric keys, press
a Rapid key, or specify a Speed Dial
number (a group key cannot be used).
To clear a mistake when
entering a full number with the
numeric keys, press the [C] key
to clear one digit at a time.
entering a full number with the
numeric keys, press the [C] key
to clear one digit at a time.
A destination selected with a Rapid key or Speed Dial
number is indicated by an icon and a number. To clear
an entry, press the [C] key.
number is indicated by an icon and a number. To clear
an entry, press the [C] key.
7
Press the [OK] key.
8
Press the [START] key.
"Polling reservation has been
set." appears in the screen.
After communicating with the
other machine, your machine
prints the received fax.
set." appears in the screen.
After communicating with the
other machine, your machine
prints the received fax.
If the other machine is using polling security (see "Restricting polling access (polling security)" on page 41), your
fax number (sender's number) must be programmed in the key operator programs (see "OWN PASSCODE SET"
on page 96) and your number must also be programmed in the other machine.
fax number (sender's number) must be programmed in the key operator programs (see "OWN PASSCODE SET"
on page 96) and your number must also be programmed in the other machine.
Note
2-SIDED
COPY
SPECIAL FUNCTION
ACC.
DUPLEX SCAN
GH
PQR
2-SIDED
COPY
SPECIAL FUNCTION
SPECIAL FUNCTION
FAX PRINT HOLD
TIMER MODE
FAX PRINT HOLD
TIMER MODE
SENDING OPTIONS
GHI
OK
BACK
SENDING OPTIONS
POLLING
SERIAL POLLING
SUB ADDRESS TX
SUB ADDRESS TX
OK
WXYZ
26
27
28
29
31
32
33
34
A
B
C
F
G
H
OK
WXYZ
@.-_
READ-END
To cancel the operation
During communication: Cancel as explained in "Cancelling a fax transmission" on page 26.
While the job is stored: Cancel as explained in "Cancelling a stored transmission job" on page 27.
While the job is stored: Cancel as explained in "Cancelling a stored transmission job" on page 27.
Note
Pegasus-E_Fax_Ex.book 37 ページ 2004年10月18日 月曜日 午後8時41分
38
ADVANCED TRANSMISSION METHODS
Serial polling
When performing serial polling, an auto-dial key that includes a sub-address or passcode (page 48) cannot be
selected.
selected.
1
Perform steps 1 to 3 of the polling
procedure (page 37).
procedure (page 37).
2
Select "SERIAL POLLING" with the
[
[
] or [
] key.
About the steps that follow
See steps 5 to 8 of the polling procedure (page 37).
Before pressing the [START] key in step 8, repeat
steps 6 and 7 for each machine that you wish to poll.
When performing serial polling, a group key can also
be used in step 6 on page 37.
Before pressing the [START] key in step 8, repeat
steps 6 and 7 for each machine that you wish to poll.
When performing serial polling, a group key can also
be used in step 6 on page 37.
GH
PQR
2-SIDED
COPY
SPECIAL FUNCTION
SENDING OPTIONS
POLLING
POLLING
SERIAL POLLING
SUB ADDRESS TX
Pegasus-E_Fax_Ex.book 38 ページ 2004年10月18日 月曜日 午後8時41分
Click on the first or last page to see other AR-M165-207 (serv.man25) service manuals if exist.