Sharp AR-M165-207 (serv.man17) Service Manual ▷ View online
AR-M207 M165 M162 SIMULATIONS 7-18
24
13
Scanner counter clear
Used to clear the scanner counter.
[OK] or [START] key: Clears the scanner counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
14
SPF jam total counter clear
Used to clear the SPF jam total counter.
[OK] or [START] key: Clears the SPF jam total counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
15
Scanner mode counter clear
Used to clear the scanner mode counter.
[OK] or [START] key: Clears the scanner mode counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
25
01
Main motor operation check (Cooling fan motor rotation check)
When [OK] key or [START] key is pressed, the main motor (as well as the duplex motor in the case of the
duplex model) is rotated for 30 sec.
If the developing unit is installed to save toner consumption at that time, the developing bias, the main
charger, and the grid are also outputted.
In addition, since laser discharge is required when the motor is stopped, the polygon motor is also operated.
Check if the developing unit is installed or not. If it is not installed, the previous high voltage is not outputted
and only the motor is rotated.
After completion of 30sec operation, the machine shifts to the sub code input window.
* This simulation must not be executed with the door open/close switch forcibly turned ON.
duplex model) is rotated for 30 sec.
If the developing unit is installed to save toner consumption at that time, the developing bias, the main
charger, and the grid are also outputted.
In addition, since laser discharge is required when the motor is stopped, the polygon motor is also operated.
Check if the developing unit is installed or not. If it is not installed, the previous high voltage is not outputted
and only the motor is rotated.
After completion of 30sec operation, the machine shifts to the sub code input window.
* This simulation must not be executed with the door open/close switch forcibly turned ON.
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
Main
code
code
Sub
code
Contents
Remark
Sim24-13 COUNTER CLR
AER YOU SURE? EXEC
SCAN COUNTER
CLEAR
CLEAR
Sim24-14 COUNTER CLR
AER YOU SURE? EXEC
SPF JAM COUNTER
CLEAR
CLEAR
Sim24-15 COUNTER CLR
AER YOU SURE? EXEC
SCANNER MODE
COUNTER CLEAR
COUNTER CLEAR
Sim25-1 MAIN MOTOR
PRESS OK KEY
EXEC
Sim25-1 MAIN MOTOR
EXEC
OK/START Key
(Execution start window)
(Execution window)
[07]SIMULATIONS.fm 18 ページ 2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-19
25
10
Polygon motor operation check
When [OK] or [START] is pressed, the polygon motor is rotated for 30sec.
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
26
01
Job separator setting
Used to set YES/NO of installation of the hob separator.
After installation of the job separator, setting must be manually set to YES.
After installation of the job separator, setting must be manually set to YES.
[CA] key: Exits the simulation mode. (When setting is changed, the machine exits the simulation mode and
performs the hard reset.)
[Interruption] key: Shifts to the sub code input window. (When setting is changed, it is invalid.)
[START] key: Setting contents are saved in the EEPROM and the machine shifts to the code input window.
performs the hard reset.)
[Interruption] key: Shifts to the sub code input window. (When setting is changed, it is invalid.)
[START] key: Setting contents are saved in the EEPROM and the machine shifts to the code input window.
(When setting is changed, the machine does not shift to the code input window.)
02
Size setting
Used to set Enable/Disable of FC (8.5" x 13") size detection.
Detection size when FC (8.5" x 13") size document is used.
Detection size when FC (8.5" x 13") size document is used.
* For destinations other than the above, this setting is invalid.
Default:
00
00
03
Auditor setting
Used to set the auditor.
* When the coin vendor mode is selected:
1. Sort auto select is OFF.
2. For Japan, the duplex copy use inhibition setting is ON (inhibited).
2. For Japan, the duplex copy use inhibition setting is ON (inhibited).
3. When the auditor mode exclusive-setting is ON (manual paper feed inhibited) and the standard tray is set
to the manual feed tray, the standard tray setting is set to the main tray.
Default:
0 (P10)
0 (P10)
Main
code
code
Sub
code
Contents
Remark
Sim25-10 LSU CHECK
PRESS OK KEY
EXEC
Sim25-10 LSU CHECK
EXEC
OK/START Key
(Execution start window)
(Execution window)
Sim26-1 JBS SET
1:JOB SEPARATOR
0=NONE
1=SEPARATOR
[ 0-1]
0=NONE
1=SEPARATOR
[ 0-1]
0 : No job separator
1 : Job separator provided
1 : Job separator provided
0
0
Unit to be
used
Destination
Document size
Set value
0(Disable)
1(Enable)
Document
SPF
EX Japan AB
series(FC)
series(FC)
FC(8.5"x13")
B4
FC(8.5"x13")
B4
B4
FC(8.5"x13")
Inch
series(FC)
series(FC)
FC(8.5"x13")
LG(8.5"x14")
FC(8.5"x13")
LG(8.5"x14")
LG(8.5"x14")
FC(8.5"x13")
Sim26-2 SIZE SET
1:B4/LG,FC
0=B4/LG
1=FC
[ 0-1]
0=B4/LG
1=FC
[ 0-1]
Code: Setting
0 : Detection disabled
(Default for destinations other than below)
1 : FC detection enabled
(Default for SCA/Philippines)
0 : Detection disabled
(Default for destinations other than below)
1 : FC detection enabled
(Default for SCA/Philippines)
0
0
Sim26-3 AUDITOR SET
1:AUDITOR
0=P10
0=P10
1=VENDOR
2=OTHER
[ 0-2]
[ 0-2]
Code: Mode
0 : Built-in auditor mode
1 : Coin vendor
2 : Other
0 : Built-in auditor mode
1 : Coin vendor
2 : Other
0
0
[07]SIMULATIONS.fm 19 ページ 2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-20
26
04
Copier duplex setting
Used to set YES/NO of duplex setting.
This must be set to ON when the duplex unit is installed. If this setting is set to OFF on the duplex machine,
the duplex motor dose not rotate and paper is not discharged normally, resulting in a paper jam.
This must be set to ON when the duplex unit is installed. If this setting is set to OFF on the duplex machine,
the duplex motor dose not rotate and paper is not discharged normally, resulting in a paper jam.
05
Count mode setting
Used to set the count-up number of the total counter, the developer counter, and the maintenance counter
individually when a special paper (A3/WLT/8K) is passed.
When this simulation is executed, the current set value is displayed.
individually when a special paper (A3/WLT/8K) is passed.
When this simulation is executed, the current set value is displayed.
[1]-[3] (Default:[0])
Enter a value with 10-key, and press [OK] key or [START] key to save the current adjustment value to the
EEPROM. The machine returns to the sub code input window.
Enter a value with 10-key, and press [OK] key or [START] key to save the current adjustment value to the
EEPROM. The machine returns to the sub code input window.
Default:
0 (+2)
0 (+2)
06
Destination setting
Used to set the destination of the main unit.
When this simulation is executed, the code number of currently set destination is displayed.
When this simulation is executed, the code number of currently set destination is displayed.
[0] - [6] (Default: Depends on the model.)
Enter a value with 10-key, and press [OK] key or [START] key, and the current adjustment value is saved in
the EEPROM.
[CA] key: Exits the simulation mode. (When setting is changed, the machine exits the simulation mode and
Enter a value with 10-key, and press [OK] key or [START] key, and the current adjustment value is saved in
the EEPROM.
[CA] key: Exits the simulation mode. (When setting is changed, the machine exits the simulation mode and
performs the hard reset.)
[Interruption] key: Shifts to the sub code input window. (When setting is changed, it is invalid.)
[START] key: Setting contents are saved in the EEPROM and the machine shifts to the code input window.
[START] key: Setting contents are saved in the EEPROM and the machine shifts to the code input window.
(When setting is changed, the machine does not shift to the code input window.)
* When this setting is changed, the following adjustment values and the set values are automatically
changed according to the set destination.
O SIM46-19 (
table setting)
O SIM46-30 (AE limit setting)
O Paper size (A4 for AB series, LT for inch series)
O Maintenance cycle (Returns to the default (Japan/Ex Japan). )
O Mini maintenance cycle (Only when setting is changed to Japan.)
O Paper size (A4 for AB series, LT for inch series)
O Maintenance cycle (Returns to the default (Japan/Ex Japan). )
O Mini maintenance cycle (Only when setting is changed to Japan.)
Default:
1
1
Main
code
code
Sub
code
Contents
Remark
Sim26-4 DUPLEX SET
1:DUPLEX
0=OFF
0=OFF
1=ON
[ 0-1]
Code: Duplex setting
0 : OFF
1 : ON
0 : OFF
1 : ON
0
0
Sim26-5 COUNT MODE
1:COUNT MODE
[ 0-3]
[ 0-3]
1
1
Setting
Total/Developer
Maintenance
0
+2
+2
1
+1
+2
2
+2
+1
3
+1
+1
Sim26-6 DESTINATION
1:DESTINATION
0=JAPAN
[ 0-6]
0=JAPAN
[ 0-6]
Code
:Setting
0=JAPAN
: Japan AB series
1=INCH
: Inch series
2=AB
: Ex Japan AB series
3=INCH(FC)
: Ex Japan inch series (FC)
4=AB(FC)
: Ex Japan AB series (FC)
5=CHINESE
: China (EX Japan AB series + Chinese paper support)
6=TAIPEI
: Taiwan (EX Japan AB series + Chinese paper support)
(Setting range 0 - 6)
0
0
[07]SIMULATIONS.fm 20 ページ 2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-21
26
07
Machine condition check
When this simulation is executed, the copy speed of the machine is displayed.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
[Interruption] key: Shifts to the sub code input window.
18
Toner save mode setting
Used to switch ON/OFF of the toner save mode.
When this simulation is executed, the current set value is displayed. Enter a set value with 10-key and press
[OK] key or [START] key. The set value is saved in the EEPROM.
* When this setting is changed, the toner save setting of the key operator program is also changed
When this simulation is executed, the current set value is displayed. Enter a set value with 10-key and press
[OK] key or [START] key. The set value is saved in the EEPROM.
* When this setting is changed, the toner save setting of the key operator program is also changed
accordingly.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
[Interruption] key: Shifts to the sub code input window.
Default:
0 (Toner save OFF)
0 (Toner save OFF)
20
Job separator paper exit mode setting
Used to set the paper exit mode of the job separator.
* The purpose is to allow the simplified check when the job separator option is installed. It is valid only
* The purpose is to allow the simplified check when the job separator option is installed. It is valid only
during the adjustment simulation. Without installing a printer or a FAX machine, paper is discharged to the
upper stage to check if there is no problem or not.
If SIM26-01 is set to "Job separator not installed," paper is discharged to the lower stage regardless of
this setting.
this setting.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
[Interruption] key: Shifts to the sub code input window.
Default:
0 (OFF)
0 (OFF)
22
Language setting clear
Used to clear the language setting. The scanner head is shifted to the fixing lock position.
(1) Initial display
(1) Initial display
(2) Press [OK]or [START] key.(Execution is starred.)
(3) After completion of counter clear and shifting to the lock position
Main
code
code
Sub
code
Contents
Remark
Sim26-7 CPM CHECK
16CPM
Displayed CPM list
14CPM
16CPM
20CPM
14CPM
16CPM
20CPM
Sim26-18 TONER SAVE
1:TONER SV MODE
0=OFF 1=ON
[ 0-1]
0=OFF 1=ON
[ 0-1]
Code: Setting
0: Toner save OFF
1: Toner save ON
0: Toner save OFF
1: Toner save ON
0
0
Sim26-20 JOBSEP OUT
1:JOBSEP OUT
0=OFF
0=OFF
1=ON
[ 0-1]
Code: Setting
0: Lower tray
1: Upper tray
0: Lower tray
1: Upper tray
0
0
Sim26-22 LANGUAGE
AER YOU SURE? EXEC
LANGUAGE SETTING
CLEAR
CLEAR
Sim26-22 LANGUAGE
LANGUAGE SETTING
CLEAR
CLEAR
EXEC
Sim26-22 LANGUAGE
PLEASE SHUT OFF
THE POWER.
THE POWER.
[07]SIMULATIONS.fm 21 ページ 2004年11月17日 水曜日 午後12時11分
Click on the first or last page to see other AR-M165-207 (serv.man17) service manuals if exist.