DOWNLOAD Sharp AR-M165-207 (serv.man17) Service Manual ↓ Size: 13.1 MB | Pages: 127 in PDF or view online for FREE

Model
AR-M165-207 (serv.man17)
Pages
127
Size
13.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual
File
ar-m165-207-sm17.pdf
Date

Sharp AR-M165-207 (serv.man17) Service Manual ▷ View online

AR-M207 M165 M162 SIMULATIONS 7-10
07
08
Shifting with warm-up display
Used to measure the warm-up time.
When this simulation is executed, the following warm-up window is displayed.
The time required for starting the warm-up and completing the initializing operation and shifting to the stand-
by state is displayed.
* Though [CA] key is  pressed, the machine does not enter the aging mode of intermission 0 sec.
Press [CA] key to exit the simulation mode.
(The aging function is omitted from SIM 07-01.)
08
01
Developing bias output
Used to check the developing bias output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the developing bias signal is turned ON for 30sec. When 
measuring the actual output value, however, use SIM 25-01.
After completion of the process, the machine returns to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts output operation and shifts to the sib code input window. 
02
Main charger output (Grid = HIGH)
Used to check the main charger output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the main charger is turned on for 30 sec in the grid voltage HIGH 
mode.
After completion of the process, the machine returns to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts output operation and shifts to the sub code input window. 
03
Main charger output (Grid = LOW)
Used to check the main charger output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the main charger is turned on for 30 sec in the grid voltage LOW 
mode.
After completion of the process, the machine returns to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts output operation and shifts to the sub code input window.
Main 
code
Sub 
code
Contents
Remark
Sim7-8 W-UP C-MODE
WARMING UP.
1
(Warming up window)
Sim7-8 W-UP C-MODE
WARM UP COMPLETED.
10
(Warming up completion window)
Sim8-1    DV BIAS
PRESS OK KEY
EXEC
Sim8-1    DV BIAS
EXEC
OK/START Key
(Execution start window)
(Execution window)
Sim8-2    MHV(H)
PRESS OK KEY
EXEC
Sim8-2    MHV(H)
EXEC
OK/START Key
(Execution start window)
(Execution window)
Sim8-3    MHV(L)
PRESS OK KEY
EXEC
Sim8-3    MHV(L)
EXEC
OK/START Key
(Execution start window)
(Execution window)
[07]SIMULATIONS.fm  10 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-11
08
06
Transfer charger output
When this simulation is executed, the machine shifts to the following mode select window, and the list of the 
modes to be outputted is displayed.
Select an output mode with 10-key and press [OK] key or [START] key, and the transfer charger output is 
made for about 30sec in the specified mode.
* The back is not displayed when DUPEX setting is OFF.
* Small size paper is Letter R (A4R) width or below. When an output is completed, the machine shifts to the
mode select window. 
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
09
01
Duplex motor forward rotation check
Used to check the duplex motor rotation.
The duplex motor is rotated in the normal direction (paper exit direction) for 30sec.
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
02
Duplex motor reverse rotation check
Used to check the duplex motor reverse rotation.
The duplex motor is rotated in the reverse direction for 30sec.
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
Main 
code
Sub 
code
Contents
Remark
Sim8-6 TC OUTPUT
1:NML_A
2:NML_B
3:SML_A
4:SML_B
5:BYPASS
2
(Mode selection window)
Sim8-6 TC OUTPUT
1:NML_A
2:
NML_B
3:SML_A
4:SML_B
5:BYPASS
2
EXEC
(Execution window)
OK/START Key
EXEC
Window display
 Output mode
1:NML_A
 Normal size width (front)
2:NML_B
 Normal size width (back)
3:SML_A
 Small size width (front)
4:SML_B
 Small size width (back)
Sim9-1    DMF CHECK
PRESS OK KEY
EXEC
Sim9-1    DMF CHECK
EXEC
OK/START Key
(Execution start window)
(Execution window)
Sim9-2    DMR CHECK
PRESS OK KEY
EXEC
Sim9-2    DMR CHECK
EXEC
OK/START Key
(Execution start window)
(Execution window)
[07]SIMULATIONS.fm  11 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-12
09
04
Duplex motor RPM adjustment
Used to adjust the duplex motor rotation speed.
When this simulation is executed, the following setting window is displayed. Enter an input value with 10-key 
and press [OK] key or [START] key.
The setting range is in 1-13 steps and the default is "4" (646.9PPS).
When a value outside the setting range is inputted, it is ignored.
[CA] key: Exits the simulation mode.
[Interruption] key: Shift to the sub code input window.
Default:
4(646.9PPS)
05
Duplex motor switchback time adjustment
Used to adjust the duplex motor switchback time when the motor reverse rotation is controlled.
When this simulation is executed, the following setting window is displayed. Enter an input value with 10-key 
and press [OK] key or [START] key.
The setting range is 50-76, and the default is 50.
When the adjustment value is increased by 1, the distance up to reverse start is increased by 3 steps in 1-2 
phase excitement.
When a value outside the setting range is inputted, it is ignored.
[CA] key: Exits the simulation mode.
[Interruption] key: Shift to the sub code input window.
Default:
50
10
-
Toner motor operation
Used to check the operation of the toner motor.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or 
[START] key, and the toner motor is rotated for about 30sec.
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
14
-
Trouble cancel (except for U2)
* Used to cancel EEPROM writing troubles such as H trouble and execute the hard reset.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or 
[START] key to clear the trouble other than U2.
Main 
code
Sub 
code
Contents
Remark
Sim9-4  MOTOR SPEED
4
4
[    1-13]
1:MOTOR SPEED
(Setting window)
Set value : Speed (PPS)
01
: 637.2PPS(Slow)
02
: 640.4PPS
03
: 643.6PPS
04
: 646.9PPS(Default)
05
: 650.1PPS
06
: 653.3PPS
07
: 656.5PPS
08
: 659.8PPS
09
: 662.9PPS
10
: 666.2PPS
11
: 669.4PPS
12
: 672.6PPS
13
: 675.8PPS(Fast)
Sim9-5  SW BACK TIME
50
50
[   50-76]
1:SW BACK TIME
Sim10  TONER MOTOR
PRESS OK KEY
EXEC
Sim10  TONER MOTOR
EXEC
OK/START Key
(Execution start window)
(Execution window)
Sim14 TROUBLE CLEAR
AER YOU SURE? EXEC
TROUBLE CLEAR
(WITHOUT U2)
(Execution start window)
[07]SIMULATIONS.fm  12 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-13
16
-
U2 trouble cancel
* Used to cancel the U2 trouble and execute the hard reset.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or 
[START] key to clear the U2 trouble.
20
01
Maintenance counter clear
Used to clear the maintenance counter.
Press [OK] key or A[START] key on the following window, the maintenance counter is cleared and the 
machine returns to the sub code input window.
21
01
Maintenance cycle setting
Used to set the maintenance cycle. When this simulation is executed, the current set value is displayed. 
Enter a desired code with 10-key and press [START] key. The set value is saved in the EEPROM and the 
machine returns to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Returns to the sub code input window.
Default:
4(50k)
Main 
code
Sub 
code
Contents
Remark
Sim16  TROUBLE CLEAR
AER YOU SURE? EXEC
U2 TROUBLE CLEAR
(Execution start window)
Sim20-1 COUNTER CLR
AER YOU SURE? EXEC
MAINTENANCE COUNTER
CLEAR
Sim21-1 CYCLE SET.
4
4
[    0-  5]
1:MAINTE CYCLE
0: 5K (5,000 sheets)
1: 7.5K (7,500 sheets)
2: 10K (10,000 sheets)
3: 25K (25,000 sheets)
4: 50K (50,000 sheets)
5: FREE (999,999 sheets)
(Setting range: 0 - 5, Default = 4)
[07]SIMULATIONS.fm  13 ページ  2004年11月17日 水曜日 午後12時11分
Page of 127
Display

Click on the first or last page to see other AR-M165-207 (serv.man17) service manuals if exist.