AR-M207 M165 M162 SIMULATIONS 7-14
22
01
Counters display
Though SIM26-74 is set to “1: Scan counter is added,” the count is not added to SIM22-01 total counter 
display. The setting affects only the total counter display in the key operator program. 
03
Jam memory display
Used to check the jam kind occurred in the main unit and the SPF.
The kinds of jams up to 30 items are displayed sequentially from the latest one. (The oldest one is deleted 
sequentially.) This display is used for troubleshooting. (If there are extremely many troubles in a position, it 
may be judged that a repair must be executed.)
The kinds and contents of jams to be displayed are as follows.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
,   keys: Switches to another page.
Main 
code
Sub 
code
Contents
Remark
Sim22-1 COUNTER 1/4
TOTAL
:nnnnnnn
MAINTE
:nnnnnnn
DEV
:nnnnnnn(*)
MIN_MNT :nnnnnnn(*)
DRUM
:nnnnnnn
Sim22-1 COUNTER 2/4
CPY JOB
: nnnnnnn
PRT JOB
: nnnnnnn
SCN JOB : nnnnnnn
OC SCN
: nnnnnnn
Sim22-1 COUNTER 3/4
SPF
: nnnnnnn
DUPLEX
: nnnnnnn
OTHERS
: nnnnnnn
MNTCYC : nnnnnnn
Sim22-1 COUNTER 4/4
DRM TTL : nnnnnnn
MMTCYC : nnnnnnn
(*) Either of the following two is displayed depending on the model.
DEV: Development counter (EX Japan)
MIN_MNT: Mini maintenance counter (Japan)
Counter display
TOTAL
: Total counter
MAINTE
: Maintenance counter (AR model)
DEV
: Development counter (AR EX Japan model)
MIN MNT : Mini maintenance counter (AR Japan model)
DRUM
: Drum counter
CPY JOB : Copy job counter
PRT JOB : Print job counter
SCN JOB : Scan job counter
OC SCN : OC scan counter
SPF
: SPF counter
DUPLEX : DUPLEX counter
OTHERS : Other counter
MNTCYC : Maintenance cycle (AR model)
DRM TTL  :Drum rotation accumulated time 
MMTCYC : Mini maintenance cycle (AR Japan model)
Sim22-3 JAM HIS. 1/4
XXXXXXX   XXXXXXX
XXXXXXX   XXXXXXX
XXXXXXX   XXXXXXX
XXXXXXX   XXXXXXX
Sim22-3 JAM HIS. 2/4
XXXXXXX   XXXXXXX
XXXXXXX   XXXXXXX
XXXXXXX   XXXXXXX
XXXXXXX   XXXXXXX
Kinds of jams and display contents
SPPD_ON
: SPF paper entry sensor (Not reached)
SPPD_OFF : SPF paper entry sensor (Remaining)
SOUT_ON
: SPF paper exit sensor (Not reached)
SOUT_OFF : SPF paper exit sensor (Remaining)
POUT_ON
: Paper exit sensor (Not reached)
POUT_OFF : Paper exit sensor (Remaining)
DPX_ON
: DUP sensor (Not reached)
DPX_OFF
: DUP sensor (Remaining)
PIN_ON
: Paper feed sensor (Not reached)
PIN_OFF
: Paper feed sensor (Remaining)
PIN2_ON
: Cassette 2 paper feed sensor (Not reached)
PIN3_ON
: Cassette 3 paper feed sensor (Not reached)
PIN4_ON
: Cassette 4 paper feed sensor (Not reached)
[07]SIMULATIONS.fm  14 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-15
22
04
Jam total counter display
Used to display the jam total counter.
07
Key operator code display
Used to display the key operator code.
09
Paper feed counter display
Used to display the paper feed quantity of each paper feed tray. This simulation shows the use frequency of 
each paper feed section.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
   ,   keys: Switches to another page.
* TRAY2-TRAY4 are displayed only when they are installed.
13
CRUM destination display
Used to display the CRUM chip destination code saved in the EEPROM. If the display does not match the 
destination code saved in the CRUM chip, it is judged as an error.
* This simulation is valid only for the model with the CRUM chip.
14
P-ROM version display
The version of the option board which is not installed is not displayed. 
Main 
code
Sub 
code
Contents
Remark
Sim22-4 COUNTER
JAM        :        nnnnnn
Sim22-7  KEY OPE
KEY CODE:
nnnnn
Sim22-9 COUNTER 1/2
BYPASS
: nnnnnnn
TRAY1
: nnnnnnn
TRAY2
: nnnnnnn
TRAY3
: nnnnnnn
Sim22-9 COUNTER 2/2
TRAY4
: nnnnnnn
Key
Key
Sim22-13  CRUM
CRUM TYPE    nn
Number : Setting (Destination)
00
: Not set.
01
: BTA-A
02
: BTA-B
03
: BTA-C
04
: BTA-E
12
: AL series
99
: Conversion
Sim22-14 ROM VER1/2
S/N
: -----------
MCU
: --.--
IMC
: --.--
PNL
: --.--
Sim22-14 ROM VER2/2
FAX
: --.--
S/N
:Production serial number
MCU
:Main unit program version
IMC
:IMC program version 
PNL
:Panel program version
FAX
:FAX program version 
[07]SIMULATIONS.fm  15 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-16
22
15
Trouble memory display
The latest 20 troubles are displayed. (The oldest one is overwritten sequentially.)
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
   ,   keys: Switches to another page.
The display sequence is as shown below.
In this case, (1) is the latest one and (12) is the oldest.
22
SPF jam counter display
Used to display the SPF JAM counter.
When [Interruption] key is pressed, the machine goes to the sub code input window. When [CA] key is 
pressed, the machine exits the simulation mode.
24
01
Jam total counter clear
When this simulation is executed, the clear confirmation window is displayed as shown below.
When [OK] key or [START] key is pressed, the jam total count and the jam memory are cleared and the 
machine shifts to the sub code input window.
02
Trouble memory clear
Used to clear the trouble memory and the trouble history data in the EEPROM.
When [Interruption] key is pressed, the machine shifts to the sub code input window. When [CA] key is 
pressed, the machine exits the simulation mode.
04
SPF counter clear
Used to clear the SPF paper feed counter.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Main 
code
Sub 
code
Contents
Remark
Sim22-15 TROUBLE 1/2
Sim22-15 TROUBLE 2/2
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX
Key
Key
Sim22-15 TROUBLE 1/2
1
2
3
4
5
6
7
8
9
10
11
12
Sim22-22 JAM CNT 
SPF
: nnnnnnn
Sim24-1 COUNTER CLR
AER YOU SURE? EXEC
JAM COUNTER CLEAR
Sim24-2 COUNTER CLR
AER YOU SURE? EXEC
TROUBLE COUNTER 
CLEAR
Sim24-4 COUNTER CLR
AER YOU SURE? EXEC
SPF COUNTER 
CLEAR
[07]SIMULATIONS.fm  16 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-17
24
05
Duplex print counter clear
Used to clear the duplex print counter.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
06
Paper feed counter clear
Used to clear the paper feed counter data in each paper feed section.
* TRAY2-TRAY4 are displayed only when they are installed.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
07
Drum counter clear
Used to clear the drum counter and the drum rotating time.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
08
Copy counter clear
Used to clear the copy counter.
[OK] or [START] key: Clears the copy counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
09
Printer counter clear
Used to clear the printer counter and other counters.
Select a counter to be cleared and press [OK] key or [START] key. The confirmation window is displayed. 
Press [OK] key or [START] key again, and the specified counter is cleared and the machine returns to the 
initial window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Main 
code
Sub 
code
Contents
Remark
Sim24-5 COUNTER CLR
AER YOU SURE? EXEC
DUPLEX COUNTER 
CLEAR
Sim24-6 COUNTER CLR
Sim24-6 COUNTER CLR
Sim24-6 COUNTER CLR
10 Key
1:BYPASS
2:TRAY1
3:TRAY2
4:TRAY3
5:TRAY4
0
1:BYPASS
2:TRAY1
3:TRAY2
4:TRAY3
5:TRAY4
2
1:BYPASS
2:TRAY1
3:TRAY2
ARE YOU SURE?
4:TRAY3
5:TRAY4
2
C Key
OK/START
OK/START
Return
(Initial window
(Counter selection window)
(Confirmation window)
Sim24-7 COUNTER CLR
AER YOU SURE? EXEC
DRUM COUNTER 
CLEAR
Sim24-8 COUNTER CLR
AER YOU SURE? EXEC
COPIES COUNTER 
CLEAR
Sim24-9 COUNTER CLR
Sim24-9 COUNTER CLR
1:PRINT
2:OTHER
OK/START
OK/START(Counter clear)
Return
10-key input
1
1:PRINT
2:OTHER
1
ARE YOU SURE?
[07]SIMULATIONS.fm  17 ページ  2004年11月17日 水曜日 午後12時11分