DOWNLOAD Sharp AR-M165-207 (serv.man17) Service Manual ↓ Size: 13.1 MB | Pages: 127 in PDF or view online for FREE

Model
AR-M165-207 (serv.man17)
Pages
127
Size
13.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual
File
ar-m165-207-sm17.pdf
Date

Sharp AR-M165-207 (serv.man17) Service Manual ▷ View online

AR-M207 M165 M162 SIMULATIONS 7-22
26
30
CE mark conformity control ON/OFF
Used to set Yes/No of CE mark conformity.
When this simulation is executed, the current set value is displayed. Enter a value with 10-key and press 
[OK] key or [START] key. The set value is saved to EEPROM and the machine returns to the sub code input 
window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
1 (ON)
31
Auditor mode exclusive setup
Used to set whether paper feed is allowed from the manual paper feed tray of not when the auditor is set to 
the coin vendor mode.
* When this setting is set to ON, if the auditor mode is the coin vendor mode and the standard tray setting is
set to the manual paper feed tray, the standard tray setting is set to the main tray.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
1 (ON)
36
Cancel of stop at maintenance life over
Used to set YES/NO of cancel of stop when the maintenance counter life is over.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
1 (Stop cancel)
37
Cancel of stop at developer life over
Used to set YES/NO of cancel of stop when the developer counter life is over.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
39
Memory capacity check
Used to check the capacity of the image memory (SDRAM) installed to the MCU PWB and the capacity of 
the IMC compression memory.
There are two kinds of the displayed image memory capacity: 16MB and 32MB.
The standard capacity of the IMC compression memory is 16B.
* It is not displayed when IMC is not installed.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Main 
code
Sub 
code
Contents
Remark
Sim26-30 CE MARK
1:CE MARK CTRL
 0=OFF
1=ON 
                
                  [   0-1]
Code: Setting
0 : CE mark support control OFF (*Default of 100V series)
1 : CE mark support control ON (*Default of 200V)
0
0
Sim26-31 AUDITOR
1:AUDITOR
                  [   0-2]
Code: Setting
0 : Exclusive setting OFF (Manual paper feed enable)
1 : Exclusive setting ON (Manual paper feed disable) (Default)
2 : Exclusive setting OFF (Manual paper feed enable) + A3/WLT charge 
1
1
Sim26-36 MAINTESTOP
1:MAINTE OVER
                  [   0-1]
Code: Setting
0 : Stop
1 : Stop cancel (Default)
1
1
Code: Setting
0 : Stop
1 : Stop cancel (Default)
Sim26-37  DEVE STOP
1:DEV LIFE OVER
                  [   0-1]
1
1
Sim26-39 MEMORY CHK
MCU
: 32Mbyte
IMC
: 16Mbyte
[07]SIMULATIONS.fm  22 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-23
26
42
Transfer ON/OFF timing control setting
Used to set the ON/OF timing of the transfer charger (TC) individually. Select an item to be changed with the 
cross key, and change the set value to a desired value, and press [OK] key or [START] key. The entered 
value is saved to the EEPROM and the machine shifts to the sub code input window.
Variation in the adjustment value
* Setting range is 1 - 99.
When the set value is increased by 1, the timing is increased by 2ms.
* The default (38) of transfer ON timing means 320ms from PS release.
The default (50) of the transfer OFF timing means304ms from P-IN OFF.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
38 (TC ON)
50 (TC OFF)
43
Side void amount setting
Used to set the left and right side void amounts. The left side void amount and the right side void amount 
can be set individually. Select an item to be changed with the cross key and change the set value to a 
desired value. The setting range is 0-10. When the value is increased by 1, the void amount is increased by 
0.5mm. The default is 5 (= 2.5mm).
Display: Set item
1:SIDE BOID(L) : Left side void amount setting
2:SIDE VOID(R) : Right side void amount setting
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
5 (Voide amount: 
2.5mm)
Main 
code
Sub 
code
Contents
Remark
(Item selection)
Sim26-42 TC  TIMING
Sim26-42 TC  TIMING
Sim26-42 TC  TIMING
2
1:TC(ON)
2:TC(OFF)
     [      1-  99]
38
50
50
1:TC(ON)
2:TC(OFF)
     [      1-  99]
38
50
60
1:TC(ON)
2:TC(OFF)
    [      1-  99]
60
50
60
(Value input)
(Settlement)
OK/START Key
10 Key
Key
1:TC(ON)
2:TC(OFF)
PS release  
 TC ON
PIN OFF 
 TC OFF
Set value
Time (ms)
Difference (ms)
Set value
Time (ms)
Difference (ms)
99
442
+122
99
402
+98
• • •
• • •
• • •
• • •
• • •
• • •
50
344
+24
51
306
+2
• • •
• • •
• • •
• • •
• • •
• • •
38
320
Default
49
302
-2
• • •
• • •
• • •
• • •
• • •
• • •
1
246
-74
1
206
-98
(Item selection)
Sim26-43 SIDE  VOID
Sim26-43 SIDE  VOID
Sim26-43 SIDE  VOID
2
1:SIDE VOID(L)
2:SIDE VOID(R)
     [      0-  10]
3
3
3
1:SIDE VOID(L)
2:SIDE VOID(R)
     [      0-  10]
3
3
4
1:SIDE VOID(L)
2:SIDE VOID(R)
    [      0-  10]
4
3
4
(Value input)
(Settlement)
OK/START Key
10 Key
Key
[07]SIMULATIONS.fm  23 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-24
26
51
Copy temporary stop function setting
Used to set whether copying is stopped temporarily when the paper exit tray full is detected. When the 
electronic sort function is used, paper exit of 250 sheets (*1) or more can be used for one copy job. If, at that 
time, copying (paper discharge) is continued with the tray full, a paper exit jam may occur. To avoid this, 
copying is temporarily stopped by this setting.
(*1) 150 sheets when the job separator is installed.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
1 (Temporary stop)
54
LCD contrast PWM duty setting
Used to set the PWM duty (brightness) at the center value of LCD contrast.
* Setting range: 30-70(Default: 50)
* When [OK] key or [START] key is pressed, the set value of LCD contrast is immediately reflected.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
50
60
FAX mode key Enable/Disable setting
Used to set Enable/Disable of the FAX mode key when the FAX PWB is not installed.
Though this setting is set to Enable, if the FAX PWB is not installed, a message of "FAX PWB is not 
installed" is displayed.
* When the FAX PWB is installed, the display shifts to the FAX window regardless of this setting.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
0 (Enable)
73
Toner save setting display/non-display
Used to set Enable/Disable of the toner save setting in the key operator program. If this setting is set to 
Enable (1), the toner save setting appears in the key operator program to allow setting.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
01(Enable)
Main 
code
Sub 
code
Contents
Remark
Sim26-51 COPY STOP
1:COPIES STOP
0=NON STOP
1=STOP
                  [   0-1]
0
1
Display: Setting
0 : Temporary stop cancel
1 : Temporary stop (Default)
Sim26-54 LCD DUTY
1:LCD PWM DUTY
     [   30-   70]
50
50
Sim26-60 FAX KEY
1:FAX KEY MODE
     [    0-     1]
0
0
FAX PWB
Setting
Yes
No
(Enable)
FAX window display 
FAX not-installed display 
(Disable)
FAX window display 
Error beep sound
Sim26-73 TS ENABLE
1:TS ENABLE
     [      0-  1]
0
0
Display: Setting
0 : Disable
1 : Enable
[07]SIMULATIONS.fm  24 ページ  2004年11月17日 水曜日 午後12時11分
AR-M207 M165 M162 SIMULATIONS 7-25
26
74
Total counter display change setting
Used to set whether the scanner counter value is added to the total counter display in the key operator 
program.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window. 
Default:
0 (Scan counter not 
added)
30
01
Paper sensor status display
Used to display the list of paper sensor status on the LCD. An active sensor is highlighted.
The display items and corresponding sensors are shown below.
When a multi-stage cassette is not installed as an option, the corresponding sensor name is not displayed. 
41
01
Document size detection photo sensor check
Used to check the operation of the document sensor.
When this simulation is executed, the status of the document sensor is displayed.
An active sensor display is highlighted.
* For AB series, PD1-PD5; for inch series, PD1 - PD4.
Main 
code
Sub 
code
Contents
Remark
Sim26-74 ADD COUNT
1:ADD SCAN CNT
     [      0-  1]
0
0
0 : Scan counter not added
1 : Scan counter added
Display
: Corresponding sensor
POUT
: Paper exit sensor
DPX
: DUPLEX sensor
PIN
: Paper entry sensor 
MBEMP
: Manual feed paper sensor
C1EMP
: No. 1 tray paper sensor
C2EMP
: No. 2 tray paper sensor 
C3EMP
: No. 3 tray paper sensor 
C4EMP
: No. 4 tray paper sensor 
C2PSS
: No. 2 tray paper feed sensor
C3PSS
: No. 3 tray paper feed sensor
C4PSS
: No. 4 tray paper feed sensor
DRST
: New drum sensor (AL model only)
Sim30-1 SENSOR
POUT
DPX
PIN
MBEMP C1EMP C2EMP
C3EMP
C4EMP
C2PSS
C3PSS C4PSS
DRST
Sim41-1 PD SENSOR
OCSW
PD1
PD2
PD3
PD4
PD5
OC cover open/close sensor status
Document sensor status
OCSW
Open
Close
PD1 - PD5
Document NO Document 
YES
Highlighted
Normal display
Normal display Highlighted
[07]SIMULATIONS.fm  25 ページ  2004年11月17日 水曜日 午後12時11分
Page of 127