101 
16.5.7  Water Flow Switch Abnormality (H62) 
Malfunction Decision Conditions: 
During operation of cooling and heating, the water flow detected by the indoor water flow switch is used to 
determine water flow error. 
 
Malfunction Caused: 
1  Faulty water pump. 
2  Water leak in system. 
3  Faulty connector connection. 
4  Faulty water flow switch. 
5  Faulty indoor unit PCB (main). 
 
Abnormality Judgment: 
Continue for 10 seconds (but no judgment for 9 minutes after compressor startup/restart). 
 
 
102 
16.5.8  Outdoor High Pressure Abnormality (H64) 
Malfunction Decision Conditions: 
During operation of cooling and heating, when the outdoor high pressure sensor output signal is 0 Vdc or 5 Vdc. 
 
Malfunction Caused: 
1  Faulty connector connection. 
2  Faulty sensor. 
3  Faulty outdoor unit PCB (main). 
 
Abnormality Judgment: 
Continue 4 times in 20 minutes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
103 
16.5.9  Deice Circulation Error (H65) 
Malfunction Decision Conditions: 
During startup and operation of deice (mode 2), the water flow (> 10l/min) detected by the water flow switch is 
used to determine deice circulation error. 
 
Malfunction Caused: 
1  Water flow in air-to-water heatpump indoor unit circuitry. 
2  Faulty indoor unit water flow switch. 
3  Faulty indoor unit water pump. 
4  Faulty indoor unit PCB. 
 
Abnormality Judgment: 
Continue for 10 seconds. 
 
 
 
 
 
104 
16.5.10 
Indoor Backup Heater OLP Abnormality (H70) 
Malfunction Decision Conditions: 
During operation of indoor backup heater, when no power supplies to indoor backup heater or OLP open circuit. 
 
Malfunction Caused: 
1  Faulty power supply connector connection. 
2  Faulty connector connection. 
3  Faulty indoor backup heater overload protector (OLP). 
4  Faulty indoor unit PCB (main). 
 
Abnormality Judgment: 
Continue for 60 seconds. 
 
 