DOWNLOAD JBL SOUNDFLY BT (serv.man3) Service Manual ↓ Size: 3.17 MB | Pages: 75 in PDF or view online for FREE

Model
SOUNDFLY BT (serv.man3)
Pages
75
Size
3.17 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
soundfly-bt-sm3.pdf
Date

JBL SOUNDFLY BT (serv.man3) EMC - CB Certificate ▷ View online

 
Page 28 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
Temperature Rise dT of Part 
dT (K) 
Limit max dT (K) 
CY1 body (SPS) 
27.5 
36.2 
80 
U2 body (SPS) 
19.4 
25.1 
55 
CX1 body (SPS) 
21.0 
20.3 
55 
LF1 coil (SPS) 
25.9 
22.2 
85 
PWB under BD1 (SPS) 
25.7 
27.2 
85 
PWB under Q1 (SPS) 
33.9 
38.1 
85 
C7 body (SPS) 
25.3 
27.8 
55 
PWB under D7 (SPS) 
26.9 
28.4 
85 
Enclosure inside near T1  
9.2 
18.1 
30 
Enclosure outside near T1 
2.6 
3.3 
50 
Plug holder 
1.4 
3.1 
30 
Ambient 
24.8°C 
25.2°C 
-- 
Winding temperature rise measurements 
The temperatures were measured under worst case normal mode defined in 4.2.1 
The maximum ambient temperature is declared by manufacture as 45°C. 
Ambient temperature t1 (
o
C)  ....................... : 
 
 
 
 
— 
Ambient temperature t2 (
o
C)  ....................... : 
 
 
 
 
— 
 
Temperature rise dT of winding: 
dT = (R
– R
1
) x (234.5 + t1) 
– (t2 – t1) 
             R
1
 
R
1
 
(Ω) 
R
2
 
(Ω) 
dT (K) 
Limit max (K)  Insulation class 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
7.2 
TABLE: softening temperature of thermoplastics 
N/A 
 
Temperature T of part 
T - normal 
con-di-tions (
o
C) 
T - fault 
condi-tions (
o
C) 
Min T softening 
(
o
C) 
 
 
 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
For unit: 
Between mains poles (primary fuse disconnected) 
500 
Between parts separated by basic or supplementary insulation 
1000 
Between parts separated by double or reinforced insulation 
1000 
For transformer 
 
Page 29 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Transformer (T1): primary winding to secondary winding 
1000 
Transformer (T1): secondary to core 
1000 
Any one of two layers of insulation tape used in transformer 
1000 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
For unit: 
Between mains poles (primary fuse disconnected) 
DC 2120 
No 
Between parts separated by basic or supplementary insulation 
DC 2120 
No 
Between parts separated by double or reinforced insulation 
DC 4240 
No 
For transformer 
Transformer (T1): primary winding to secondary winding 
DC 4240 
No 
Transformer (T1): secondary to core 
DC 4240 
No 
Any one of two layers of insulation tape used in transformer 
DC 4240 
No 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  .............. :  264V, if not otherwise specified 
— 
 
Frequency (Hz) ........................................................ :  60, if not otherwise specified 
— 
 
Ambient temperature (
o
C)  ....................................... :  25
 o
C, if not otherwise specified 
— 
 
No. 
Component 
Fault 
dT (K) / Component  Other results 
(include description and test duration) 
D1 
short 
-- 
Test duration: 1s                                            
F1 opened, no hazards.                             
Input: 0.14A to 0A 
C7 
short 
-- 
Test duration: 1s                                            
F1 opened, no hazards.                            
Input: 0.14A to 0A 
U1 pin 5 to 
pin 1 
short 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
U1 pin 5 to 
pin 2 
short 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
U2 pin 1 to 
pin 2 
short 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
U2 pin 1 
open 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
 
Page 30 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
No. 
Component 
Fault 
dT (K) / Component  Other results 
(include description and test duration) 
U2 pin 3 to 
pin 4 
short 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
U2 pin 4 
open 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
Q1 pin G to 
pin S 
short 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
10 
Q1 pin D to 
pin G 
short 
-- 
Test duration: 1s                                            
F1 opened, no hazards.                            
Input: 0.14A to 0A 
11 
Q1 pin D to 
pin S 
short 
-- 
Test duration: 1s                                            
F1 opened, no hazards.                            
Input: 0.14A to 0A 
12 
R14 
short 
-- 
Test duration: 1s                                            
F1 opened, no hazards.                            
Input: 0.14A to 0A 
13 
T1 pin 1 to 
pin 2 
short 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
14 
T1 pin 5 to 
pin 6 
short 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
15 
T1 pin A to 
pin B 
short 
-- 
Test duration: 10 min                                            
Unit shutdown, no damage, no hazards.  
Input: 0.14A to 0.03A 
 
Page 31 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
No. 
Component 
Fault 
dT (K) / Component  Other results 
(include description and test duration) 
16 
T1 pin A to 
pin B 
overload 
PWB under U10: 
53.7K, 
T1 coil: 113.6K, 
T1 core: 91.4K 
CY1 body: 63.4K, 
U2 body: 64.9K, 
CX1 body: 45.9K, 
LF1 coil: 50.3K, 
PWB under BD1: 
54.8K, 
PWB under Q1: 
74.3K, 
C7 body: 50.8K, 
PQB under D7: 
62.4K, 
Enclosure inside 
near T1: 43.5K, 
Enclosure Outside 
near T1: 23.5k, Plug 
holder: 20.2K,  
Ambient: 25.2
C. 
Test duration: 8hr                                            
T1 overload up to 1.62A, no damage, no 
hazards.  Input: 0.14A to 0.228A to 0.28A to 
0.34A to 0.03A 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  .................................. :   
— 
 
Ambient temperature t2 (
o
C)  .................................. :   
— 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage:  240V 
Pollution degree .. :  2 
Material Group ... :  IIIa or IIIb 
2 N force on internal parts applied: 
See below 
30 N force on outside of conductive enclosure applied: 
See below 
 
Location 
Working Voltage 
Clearance (mm) 
Creepage (mm) 
 
V rms 
V peak 
Min 
Actual 
Min 
Actual 
Power supply board 
Opposite traces under fuse (F1) 
250 
420 
3.0 
3.0 
3.0 
3.0 
Primary components to secondary 
components or accessible parts 
250 
420 
6.0 
See 
below 
6.0 
See 
below 
T1 core and L2  
 
 
 
16.1 
 
16.1 
T1 core and HS2 
 
 
 
16.1 
 
16.1 
Primary trace to secondary trace 
250 
420 
6.0 
See 
below 
6.0 
See 
below 
Under CY1 
 
 
 
6.3 
 
6.3 
Under U2 
 
 
 
6.9 
 
6.9 
Under T1 
 
 
 
7.0 
 
7.0 
Transformer (T1) 
Page of 75
Display