Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
c) Markings on supply output terminals 
No such terminals. 
N/A 
5.3 
a) Use of triangle with exclamation mark  
The marks are shown on the 
technical documents near 
every safety critical 
component. 
 
b) marking on loudspeaker grille, IEC 60417-5036 
 
N/A 
5.4 
Instructions for use 
User
’s manual was provided in 
English. 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
The statement in operating 
manual complies with the 
requirement. 
 
b) Hazardous live terminals, instructions for wiring   
No hazardous live t erminals. 
N/A 
 
c) Instructions for replacing lithium battery  
A w arning in inst ruct ion 
manual. 
 
d) Class I earth connection warning  
 
 
e) Instructions for multimedia system connection  
 
N/A 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 
N/A 
 
g) Warning: battery exposure to heat  
 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
The mains plug is used as 
disconnect  device, t he 
st at ement  w as provided in 
t he user
’ s manual. 
 
c) Instructions for permanently connected equipment    
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 
N/A 
 
Hazardous radiation 
N/A 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ................................................................................... : 
 
N/A 
 
Emission limits under fault conditions  ..................... :   
N/A 
 
7 
Heating under normal operating conditions 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts  
(see appended table 7.1) 
 
Page 9 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
The input current is small than 
0.2A. 
 
Constructional requirements with regard to the protection against electric 
shock 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
Considered. 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
The apparatus was subjected 
of humidity treatment for 168 
hrs at 40
 o
C and R.H. of 95%. 
After the tests, the tests of 10.3 
are made and pass. 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
 
N/A 
8.5 
Class I equipment  
See below. 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
Hazardous live parts to 
earthed parts are separated by 
basic insulation. 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
See below. 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Hazardous live parts to 
accessible parts are separated 
by either reinforced or double 
insulation. 
 
Page 10 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
The isolating transformer has 
been tested within this report 
and complying with subclause 
14.3. 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
Hazardous live parts and 
accessible parts separated by 
one capacitor, which used was 
certified as Y1 capacitor 
according to IEC 60384-14. 
8.7 
This clause is void  
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
 
N/A 
 
Reinforced insulation > 0,4 mm (mm)  .................... : 
The photo coupler and internal 
plastic enclosure which were 
provided distance through 
insulation of minimum 0.4 mm. 
See appended table 14 for 
details. 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
The thin sheet materials of 
polyester tape used in 
transformers. 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
(see appended table 13) 
 
Reinforced insulation, three layers any two which 
meet 10.3  
 
N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
All internal wires with only 
basic isolation are routed so 
that they are not close to any 
live bare components. 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
All internal hazardous live parts 
are separated by double or 
reinforced insulation form 
conductors connected to 
accessible parts. 
 
Page 11 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
Class I equipment. 
N/A 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
 
N/A 
8.11 
Detaching of wires  
Conductors with mechanical 
securing.                                
No wire could be became 
detached after the test below. 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
No undue reduction of 
creepage and clearance 
distances below the values 
specified in clause 13. 
 
Vibration test carried out  ......................................... : 
See subclause 12.1.2. 
8.12 
This clause is void  
 
N/A 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 
N/A 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
 
N/A 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
The internal wiring does not 
touch hot parts or sharp edges, 
which may damage its 
insulation and cause hazards. 
8.16 
Only special supply equipment can be used  
The apparatus is supplied from 
AC mains. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
See below. 
8.19.1 
Disconnect device  
The mains plug is used as the 
disconnect device and see 
also subclause 5.4.2. 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 
N/A 
8.19.2 
Mains switch ON indication  
 
N/A 
8.20 
Switch not fitted in the mains cord  
 
N/A 
8.21 
Bridging components comply with clause 14  
 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 